Radio Test Set · SCPI command reference

Rohde & Schwarz CMP180 SCPI commands

The Rohde & Schwarz CMP180 radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 297 commands for it, 154 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the CMP180 on a real bench.

Commands
297
Queries
154
Subsystems
18
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz CMP180 and writes the report from the measured results.

Get started

Control the Rohde & Schwarz CMP180 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Rohde & Schwarz CMP180's VISA address

# Paste the address of your Rohde & Schwarz CMP180 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("SOURce:GPRF:GENerator1:STATe ON")  # Turn On RF Generator
print(inst.query("CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?"))  # Query Power Meter Frequency

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Rohde & Schwarz CMP180 and writes the report from the measured results.

Get started

Run a CMP180 test without writing code

Describe the test in a sentence, for example “turn on rf generator on the CMP180, then query power meter frequency and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

297 commands in 18 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Configure (CONFigure) (152)

CommandWhat it doesArguments
CONFigure:GPRF:MEASurement1:RFSettings:FREQuency <Frequency>Set Power Meter Frequency. Sets the center frequency of the RF analyzer in Hz.Number
CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?Query Power Meter Frequency. Reads the center frequency of the RF analyzer in Hz.None
CONFigure:GPRF:MEASurement1:RFSettings:ENPower <Power>Set Power Meter Expected Power. Sets the expected nominal power of the measured RF signal in dBm.Number
CONFigure:GPRF:MEASurement1:RFSettings:ENPower?Query Power Meter Expected Power. Reads the expected nominal power of the measured RF signal in dBm.None
CONFigure:GPRF:MEASurement1:RFSettings:UMARgin <Margin>Set Power Meter User Margin. Sets the margin added to the expected nominal power to determine the reference level in dB.Number
CONFigure:GPRF:MEASurement1:RFSettings:UMARgin?Query Power Meter User Margin. Reads the margin added to the expected nominal power to determine the reference level in dB.None
CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation <Atten>Set Power Meter External Attenuation. Sets the external attenuation (or gain if negative) at the input connector in dB.Number
CONFigure:GPRF:MEASurement1:RFSettings:EATTenuation?Query Power Meter External Attenuation. Reads the external attenuation (or gain if negative) at the input connector in dB.None
CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset <Offset>Set Power Meter Mixer Level Offset. Varies the input level of the mixer in the analyzer path in dB.Number
CONFigure:GPRF:MEASurement1:RFSettings:MLOFfset?Query Power Meter Mixer Level Offset. Reads back the setting: varies the input level of the mixer in the analyzer path in dB.None
CONFigure:GPRF:MEASurement1:RFSettings:FOFFset <Offset>Set Power Meter Frequency Offset. Sets a frequency offset added to the analyzer center frequency in Hz.Number
CONFigure:GPRF:MEASurement1:RFSettings:FOFFset?Query Power Meter Frequency Offset. Reads a frequency offset added to the analyzer center frequency in Hz.None
CONFigure:GPRF:MEASurement1:POWer:MODE <Mode>Set Power Measurement Mode. Selects power or statistic (CCDF) measurement mode.Text: POWer,STATistic
CONFigure:GPRF:MEASurement1:POWer:MODE?Query Power Measurement Mode. Reads the selection: power or statistic (CCDF) measurement mode.None
CONFigure:GPRF:MEASurement1:POWer:REPetition <Repetition>Set Power Repetition. Selects single-shot or continuous power measurement.Text: SINGleshot,CONTinuous
CONFigure:GPRF:MEASurement1:POWer:REPetition?Query Power Repetition. Reads the selection: single-shot or continuous power measurement.None
CONFigure:GPRF:MEASurement1:POWer:SCOunt <Count>Set Power Statistic Count. Sets the number of measurement intervals per single shot.Number
CONFigure:GPRF:MEASurement1:POWer:SCOunt?Query Power Statistic Count. Reads the number of measurement intervals per single shot.None
CONFigure:GPRF:MEASurement1:POWer:MLENgth <Seconds>Set Power Measurement Length. Sets the length of the power evaluation interval in seconds.Number
CONFigure:GPRF:MEASurement1:POWer:MLENgth?Query Power Measurement Length. Reads the length of the power evaluation interval in seconds.None
CONFigure:GPRF:MEASurement1:POWer:SLENgth <Seconds>Set Power Step Length. Sets the time between the beginning of two consecutive measurement lengths in seconds.Number
CONFigure:GPRF:MEASurement1:POWer:SLENgth?Query Power Step Length. Reads the time between the beginning of two consecutive measurement lengths in seconds.None
CONFigure:GPRF:MEASurement1:POWer:TOUT <Seconds>Set Power Timeout. Defines a timeout for the power measurement in seconds.Number
CONFigure:GPRF:MEASurement1:POWer:TOUT?Query Power Timeout. Reads the timeout for the power measurement in seconds.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan <Span>Set FFT Span. Sets the frequency span of the FFT spectrum analyzer in Hz (rounded to allowed spans).Number
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FSPan?Query FFT Span. Reads the frequency span of the FFT spectrum analyzer in Hz (rounded to allowed spans).None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength <Length>Set FFT Length. Selects the number of samples recorded per measurement interval.Number: 1024,2048,4096,8192,16384
CONFigure:GPRF:MEASurement1:FFTSanalyzer:FFTLength?Query FFT Length. Reads the selected number of samples recorded per measurement interval.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector <Detector>Set FFT Detector. Selects the detector used to build the FFT spectrum trace.Text: PEAK,RMS
CONFigure:GPRF:MEASurement1:FFTSanalyzer:DETector?Query FFT Detector. Reads the selected detector used to build the FFT spectrum trace.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe <Mode>Set FFT Averaging Mode. Selects linear or logarithmic averaging of the average trace.Text: LINear,LOGarithmic
CONFigure:GPRF:MEASurement1:FFTSanalyzer:AMODe?Query FFT Averaging Mode. Reads the selection: linear or logarithmic averaging of the average trace.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition <Repetition>Set FFT Repetition. Selects single-shot or continuous FFT measurement.Text: SINGleshot,CONTinuous
CONFigure:GPRF:MEASurement1:FFTSanalyzer:REPetition?Query FFT Repetition. Reads the selection: single-shot or continuous FFT measurement.None
CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt <Count>Set FFT Statistic Count. Sets the statistic count of the FFT measurement.Number
CONFigure:GPRF:MEASurement1:FFTSanalyzer:SCOunt?Query FFT Statistic Count. Reads the statistic count of the FFT measurement.None
CONFigure:NRSub:MEASurement1:BAND <Band>Set NR Meas Band. Selects the NR operating band.Text: OB1,OB2,OB3,OB5,OB7,OB8,OB12,OB20,OB25,OB28,OB34,OB38,OB39,OB40,OB41,OB66,OB71,OB77,OB78,OB79
CONFigure:NRSub:MEASurement1:BAND?Query NR Meas Band. Reads the selected NR operating band.None
CONFigure:NRSub:MEASurement1:MEValuation:DMODe <Mode>Set NR Meas Duplex Mode. Selects the duplex mode of the measured NR signal.Text: FDD,TDD
CONFigure:NRSub:MEASurement1:MEValuation:DMODe?Query NR Meas Duplex Mode. Reads the selected duplex mode of the measured NR signal.None
CONFigure:NRSub:MEASurement1:RFSettings:FREQuency <Frequency>Set NR Meas Frequency. Sets the analyzer center frequency in Hz.Number
CONFigure:NRSub:MEASurement1:RFSettings:FREQuency?Query NR Meas Frequency. Reads the analyzer center frequency in Hz.None
CONFigure:NRSub:MEASurement1:RFSettings:ENPower <Power>Set NR Meas Expected Power. Sets the expected nominal power of the measured signal in dBm.Number
CONFigure:NRSub:MEASurement1:RFSettings:ENPower?Query NR Meas Expected Power. Reads the expected nominal power of the measured signal in dBm.None
CONFigure:NRSub:MEASurement1:RFSettings:UMARgin <Margin>Set NR Meas User Margin. Sets the user margin added to the expected nominal power in dB.Number
CONFigure:NRSub:MEASurement1:RFSettings:UMARgin?Query NR Meas User Margin. Reads the user margin added to the expected nominal power in dB.None
CONFigure:NRSub:MEASurement1:RFSettings:EATTenuation <Atten>Set NR Meas External Attenuation. Sets the external attenuation (or gain if negative) at the RF input in dB.Number
CONFigure:NRSub:MEASurement1:RFSettings:EATTenuation?Query NR Meas External Attenuation. Reads the external attenuation (or gain if negative) at the RF input in dB.None
CONFigure:NRSub:MEASurement1:MEValuation:CBANdwidth <Bandwidth>Set NR Meas Channel Bandwidth. Selects the NR channel bandwidth.Text: B005,B010,B015,B020,B025,B030,B040,B050,B060,B070,B080,B090,B100
CONFigure:NRSub:MEASurement1:MEValuation:CBANdwidth?Query NR Meas Channel Bandwidth. Reads the selected NR channel bandwidth.None
CONFigure:NRSub:MEASurement1:MEValuation:SCSPacing <Spacing>Set NR Meas Subcarrier Spacing. Selects the subcarrier spacing.Text: S15K,S30K,S60K
CONFigure:NRSub:MEASurement1:MEValuation:SCSPacing?Query NR Meas Subcarrier Spacing. Reads the selected subcarrier spacing.None
CONFigure:NRSub:MEASurement1:MEValuation:PLCid <Cell_ID>Set NR Meas Physical Cell ID. Sets the physical layer cell ID.Number: 0,1007
CONFigure:NRSub:MEASurement1:MEValuation:PLCid?Query NR Meas Physical Cell ID. Reads the physical layer cell ID.None
CONFigure:NRSub:MEASurement1:MEValuation:NSUBframes <Number>Set NR Meas Subframes. Sets the number of subframes to be evaluated.Number
CONFigure:NRSub:MEASurement1:MEValuation:NSUBframes?Query NR Meas Subframes. Reads the number of subframes to be evaluated.None
CONFigure:NRSub:MEASurement1:MEValuation:SCONdition <Condition>Set NR Meas Stop Condition. Defines whether the measurement stops on a limit failure.Text: NONE,SLFail
CONFigure:NRSub:MEASurement1:MEValuation:SCONdition?Query NR Meas Stop Condition. Reads whether the measurement stops on a limit failure.None
CONFigure:NRSub:MEASurement1:MEValuation:REPetition <Repetition>Set NR Meas Repetition. Selects single-shot or continuous multi-evaluation measurement.Text: SINGleshot,CONTinuous
CONFigure:NRSub:MEASurement1:MEValuation:REPetition?Query NR Meas Repetition. Reads the selection: single-shot or continuous multi-evaluation measurement.None
CONFigure:NRSub:MEASurement1:MEValuation:SCOunt:MODulation <Count>Set NR Meas Modulation Count. Sets the statistic count (measurement intervals per single shot) for modulation results.Number
CONFigure:NRSub:MEASurement1:MEValuation:SCOunt:MODulation?Query NR Meas Modulation Count. Reads the statistic count (measurement intervals per single shot) for modulation results.None
CONFigure:NRSub:MEASurement1:MEValuation:SCOunt:POWer <Count>Set NR Meas Power Count. Sets the statistic count (measurement intervals per single shot) for power results.Number
CONFigure:NRSub:MEASurement1:MEValuation:SCOunt:POWer?Query NR Meas Power Count. Reads the statistic count (measurement intervals per single shot) for power results.None
CONFigure:NRSub:MEASurement1:MEValuation:TOUT <Seconds>Set NR Meas Timeout. Defines a timeout for the measurement in seconds.Number
CONFigure:NRSub:MEASurement1:MEValuation:TOUT?Query NR Meas Timeout. Reads the timeout for the measurement in seconds.None
CONFigure:NRSub:MEASurement1:MEValuation:MOEXception ONTurn On NR Meas On Exception. Results identified as faulty are never rejected.None
CONFigure:NRSub:MEASurement1:MEValuation:MOEXception OFFTurn Off NR Meas On Exception. Faulty results are rejected.None
CONFigure:LTE:MEASurement1:BAND <Band>Set LTE Meas Band. Selects the LTE operating band.Text: OB1,OB2,OB3,OB4,OB5,OB7,OB8,OB12,OB13,OB17,OB20,OB25,OB26,OB28,OB38,OB39,OB40,OB41,OB66,OB71
CONFigure:LTE:MEASurement1:BAND?Query LTE Meas Band. Reads the selected LTE operating band.None
CONFigure:LTE:MEASurement1:DMODe <Mode>Set LTE Meas Duplex Mode. Selects the duplex mode of the LTE signal.Text: FDD,TDD
CONFigure:LTE:MEASurement1:DMODe?Query LTE Meas Duplex Mode. Reads the selected duplex mode of the LTE signal.None
CONFigure:LTE:MEASurement1:RFSettings:FREQuency <Frequency>Set LTE Meas Frequency. Sets the analyzer center frequency in Hz.Number
CONFigure:LTE:MEASurement1:RFSettings:FREQuency?Query LTE Meas Frequency. Reads the analyzer center frequency in Hz.None
CONFigure:LTE:MEASurement1:RFSettings:ENPower <Power>Set LTE Meas Expected Power. Sets the expected nominal power of the measured signal in dBm.Number
CONFigure:LTE:MEASurement1:RFSettings:ENPower?Query LTE Meas Expected Power. Reads the expected nominal power of the measured signal in dBm.None
CONFigure:LTE:MEASurement1:RFSettings:UMARgin <Margin>Set LTE Meas User Margin. Sets the user margin added to the expected nominal power in dB.Number
CONFigure:LTE:MEASurement1:RFSettings:UMARgin?Query LTE Meas User Margin. Reads the user margin added to the expected nominal power in dB.None
CONFigure:LTE:MEASurement1:RFSettings:EATTenuation <Atten>Set LTE Meas External Attenuation. Sets the external attenuation (or gain if negative) at the RF input in dB.Number
CONFigure:LTE:MEASurement1:RFSettings:EATTenuation?Query LTE Meas External Attenuation. Reads the external attenuation (or gain if negative) at the RF input in dB.None
CONFigure:LTE:MEASurement1:CC1:CBANdwidth <Bandwidth>Set LTE Meas Channel Bandwidth. Selects the channel bandwidth of component carrier 1 (1.4 to 20 MHz).Text: B014,B030,B050,B100,B150,B200
CONFigure:LTE:MEASurement1:CC1:CBANdwidth?Query LTE Meas Channel Bandwidth. Reads the selected channel bandwidth of component carrier 1 (1.4 to 20 MHz).None
CONFigure:LTE:MEASurement1:MEValuation:CTYPe <Type>Set LTE Meas Channel Type. Selects automatic or manual uplink channel type detection.Text: AUTO,PUSCh,PUCCh
CONFigure:LTE:MEASurement1:MEValuation:CTYPe?Query LTE Meas Channel Type. Reads the selection: automatic or manual uplink channel type detection.None
CONFigure:LTE:MEASurement1:MEValuation:MMODe <Mode>Set LTE Meas Mode. Selects normal, TPC or multi-evaluation list mode.Text: NORMal,TMODe,MELMode
CONFigure:LTE:MEASurement1:MEValuation:MMODe?Query LTE Meas Mode. Reads the selection: normal, TPC or multi-evaluation list mode.None
CONFigure:LTE:MEASurement1:MEValuation:PLCid <Cell_ID>Set LTE Meas Physical Cell ID. Sets the physical layer cell ID.Number: 0,503
CONFigure:LTE:MEASurement1:MEValuation:PLCid?Query LTE Meas Physical Cell ID. Reads the physical layer cell ID.None
CONFigure:LTE:MEASurement1:MEValuation:SCONdition <Condition>Set LTE Meas Stop Condition. Defines whether the measurement stops on a limit failure.Text: NONE,SLFail
CONFigure:LTE:MEASurement1:MEValuation:SCONdition?Query LTE Meas Stop Condition. Reads whether the measurement stops on a limit failure.None
CONFigure:LTE:MEASurement1:MEValuation:REPetition <Repetition>Set LTE Meas Repetition. Selects single-shot or continuous multi-evaluation measurement.Text: SINGleshot,CONTinuous
CONFigure:LTE:MEASurement1:MEValuation:REPetition?Query LTE Meas Repetition. Reads the selection: single-shot or continuous multi-evaluation measurement.None
CONFigure:LTE:MEASurement1:MEValuation:SCOunt:MODulation <Count>Set LTE Meas Modulation Count. Sets the statistic count (measurement intervals per single shot) for modulation results.Number
CONFigure:LTE:MEASurement1:MEValuation:SCOunt:MODulation?Query LTE Meas Modulation Count. Reads the statistic count (measurement intervals per single shot) for modulation results.None
CONFigure:LTE:MEASurement1:MEValuation:SCOunt:POWer <Count>Set LTE Meas Power Count. Sets the statistic count (measurement intervals per single shot) for power results.Number
CONFigure:LTE:MEASurement1:MEValuation:SCOunt:POWer?Query LTE Meas Power Count. Reads the statistic count (measurement intervals per single shot) for power results.None
CONFigure:LTE:MEASurement1:MEValuation:TOUT <Seconds>Set LTE Meas Timeout. Defines a timeout for the measurement in seconds.Number
CONFigure:LTE:MEASurement1:MEValuation:TOUT?Query LTE Meas Timeout. Reads the timeout for the measurement in seconds.None
CONFigure:LTE:MEASurement1:MEValuation:MOEXception ONTurn On LTE Meas On Exception. Results identified as faulty are never rejected.None
CONFigure:LTE:MEASurement1:MEValuation:MOEXception OFFTurn Off LTE Meas On Exception. Faulty results are rejected.None
CONFigure:WLAN:MEASurement1:ISIGnal:STANdard <Standard>Set WLAN Meas Standard. Selects the IEEE 802.11 standard (b/g DSSS, a/g OFDM, n, ac, ax, be, p).Text: DSSS,LOFDm,HTOFdm,VHTofdm,HEOFdm,EHTofdm,POFDm
CONFigure:WLAN:MEASurement1:ISIGnal:STANdard?Query WLAN Meas Standard. Reads the selected IEEE 802.11 standard (b/g DSSS, a/g OFDM, n, ac, ax, be, p).None
CONFigure:WLAN:MEASurement1:ISIGnal:BWIDth <Bandwidth>Set WLAN Meas Bandwidth. Selects the channel bandwidth (5 MHz to 320 MHz).Text: BW05mhz,BW10mhz,BW20mhz,BW40mhz,BW80mhz,BW16mhz,BW32mhz
CONFigure:WLAN:MEASurement1:ISIGnal:BWIDth?Query WLAN Meas Bandwidth. Reads the selected channel bandwidth (5 MHz to 320 MHz).None
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency:BAND <Band>Set WLAN Meas Frequency Band. Selects the WLAN frequency band.Text: B24Ghz,B4GHz,B5GHz,B6GHz
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency:BAND?Query WLAN Meas Frequency Band. Reads the selected WLAN frequency band.None
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency <Frequency>Set WLAN Meas Frequency. Sets the analyzer center frequency in Hz.Number
CONFigure:WLAN:MEASurement1:RFSettings:FREQuency?Query WLAN Meas Frequency. Reads the analyzer center frequency in Hz.None
CONFigure:WLAN:MEASurement1:RFSettings:ENPower <Power>Set WLAN Meas Expected Power. Sets the expected nominal power of the measured signal in dBm.Number
CONFigure:WLAN:MEASurement1:RFSettings:ENPower?Query WLAN Meas Expected Power. Reads the expected nominal power of the measured signal in dBm.None
CONFigure:WLAN:MEASurement1:RFSettings:UMARgin <Margin>Set WLAN Meas User Margin. Sets the user margin added to the expected nominal power in dB.Number
CONFigure:WLAN:MEASurement1:RFSettings:UMARgin?Query WLAN Meas User Margin. Reads the user margin added to the expected nominal power in dB.None
CONFigure:WLAN:MEASurement1:RFSettings:EATTenuation <Atten>Set WLAN Meas External Attenuation. Sets the external attenuation (or gain if negative) at the RF input in dB.Number
CONFigure:WLAN:MEASurement1:RFSettings:EATTenuation?Query WLAN Meas External Attenuation. Reads the external attenuation (or gain if negative) at the RF input in dB.None
CONFigure:WLAN:MEASurement1:MEValuation:SCONdition <Condition>Set WLAN Meas Stop Condition. Defines whether the measurement stops on a limit failure.Text: NONE,SLFail
CONFigure:WLAN:MEASurement1:MEValuation:SCONdition?Query WLAN Meas Stop Condition. Reads whether the measurement stops on a limit failure.None
CONFigure:WLAN:MEASurement1:MEValuation:REPetition <Repetition>Set WLAN Meas Repetition. Selects single-shot or continuous multi-evaluation measurement.Text: SINGleshot,CONTinuous
CONFigure:WLAN:MEASurement1:MEValuation:REPetition?Query WLAN Meas Repetition. Reads the selection: single-shot or continuous multi-evaluation measurement.None
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:MODulation <Count>Set WLAN Meas Modulation Count. Sets the statistic count (measurement intervals per single shot) for modulation results.Number
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:MODulation?Query WLAN Meas Modulation Count. Reads the statistic count (measurement intervals per single shot) for modulation results.None
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:TSMask <Count>Set WLAN Meas Spectrum Mask Count. Sets the statistic count (measurement intervals per single shot) for tsmask results.Number
CONFigure:WLAN:MEASurement1:MEValuation:SCOunt:TSMask?Query WLAN Meas Spectrum Mask Count. Reads the statistic count (measurement intervals per single shot) for tsmask results.None
CONFigure:WLAN:MEASurement1:MEValuation:TOUT <Seconds>Set WLAN Meas Timeout. Defines a timeout for the measurement in seconds.Number
CONFigure:WLAN:MEASurement1:MEValuation:TOUT?Query WLAN Meas Timeout. Reads the timeout for the measurement in seconds.None
CONFigure:WLAN:MEASurement1:MEValuation:MOEXception ONTurn On WLAN Meas On Exception. Results identified as faulty are never rejected.None
CONFigure:WLAN:MEASurement1:MEValuation:MOEXception OFFTurn Off WLAN Meas On Exception. Faulty results are rejected.None
CONFigure:BLUetooth:MEASurement1:ISIGnal:BTYPe <Type>Set BT Meas Burst Type. Selects the burst type: basic rate, enhanced data rate or low energy.Text: BR,EDR,LE
CONFigure:BLUetooth:MEASurement1:ISIGnal:BTYPe?Query BT Meas Burst Type. Reads the selected burst type: basic rate, enhanced data rate or low energy.None
CONFigure:BLUetooth:MEASurement1:ISIGnal:PTYPe:BRATe <Type>Set BT Meas BR Packet Type. Selects the basic rate packet type.Text: DH1,DH3,DH5
CONFigure:BLUetooth:MEASurement1:ISIGnal:PTYPe:BRATe?Query BT Meas BR Packet Type. Reads the selected basic rate packet type.None
CONFigure:BLUetooth:MEASurement1:ISIGnal:LENergy:PHY <PHY>Set BT Meas LE PHY. Selects the LE physical layer (1M, 2M, coded long range).Text: LE1M,LE2M,LELR
CONFigure:BLUetooth:MEASurement1:ISIGnal:LENergy:PHY?Query BT Meas LE PHY. Reads the selected LE physical layer (1M, 2M, coded long range).None
CONFigure:BLUetooth:MEASurement1:ISIGnal:PATTern <Pattern>Set BT Meas Payload Pattern. Selects the expected payload pattern.Text: P11,P44,OTHer,ALTernating
CONFigure:BLUetooth:MEASurement1:ISIGnal:PATTern?Query BT Meas Payload Pattern. Reads the selected expected payload pattern.None
CONFigure:BLUetooth:MEASurement1:RFSettings:FREQuency <Frequency>Set BT Meas Frequency. Sets the analyzer center frequency in Hz.Number
CONFigure:BLUetooth:MEASurement1:RFSettings:FREQuency?Query BT Meas Frequency. Reads the analyzer center frequency in Hz.None
CONFigure:BLUetooth:MEASurement1:RFSettings:ENPower <Power>Set BT Meas Expected Power. Sets the expected nominal power of the measured signal in dBm.Number
CONFigure:BLUetooth:MEASurement1:RFSettings:ENPower?Query BT Meas Expected Power. Reads the expected nominal power of the measured signal in dBm.None
CONFigure:BLUetooth:MEASurement1:RFSettings:UMARgin <Margin>Set BT Meas User Margin. Sets the user margin added to the expected nominal power in dB.Number
CONFigure:BLUetooth:MEASurement1:RFSettings:UMARgin?Query BT Meas User Margin. Reads the user margin added to the expected nominal power in dB.None
CONFigure:BLUetooth:MEASurement1:RFSettings:EATTenuation <Atten>Set BT Meas External Attenuation. Sets the external attenuation (or gain if negative) at the RF input in dB.Number
CONFigure:BLUetooth:MEASurement1:RFSettings:EATTenuation?Query BT Meas External Attenuation. Reads the external attenuation (or gain if negative) at the RF input in dB.None
CONFigure:BLUetooth:MEASurement1:MEValuation:REPetition <Repetition>Set BT Meas Repetition. Selects single-shot or continuous multi-evaluation measurement.Text: SINGleshot,CONTinuous
CONFigure:BLUetooth:MEASurement1:MEValuation:REPetition?Query BT Meas Repetition. Reads the selection: single-shot or continuous multi-evaluation measurement.None
CONFigure:BLUetooth:MEASurement1:MEValuation:SCOunt:MODulation <Count>Set BT Meas Modulation Count. Sets the statistic count (measurement intervals per single shot) for modulation results.Number
CONFigure:BLUetooth:MEASurement1:MEValuation:SCOunt:MODulation?Query BT Meas Modulation Count. Reads the statistic count (measurement intervals per single shot) for modulation results.None
CONFigure:BLUetooth:MEASurement1:MEValuation:SCOunt:PVTime <Count>Set BT Meas PvT Count. Sets the statistic count (measurement intervals per single shot) for pvtime results.Number
CONFigure:BLUetooth:MEASurement1:MEValuation:SCOunt:PVTime?Query BT Meas PvT Count. Reads the statistic count (measurement intervals per single shot) for pvtime results.None
CONFigure:BLUetooth:MEASurement1:MEValuation:TOUT <Seconds>Set BT Meas Timeout. Defines a timeout for the measurement in seconds.Number
CONFigure:BLUetooth:MEASurement1:MEValuation:TOUT?Query BT Meas Timeout. Reads the timeout for the measurement in seconds.None
CONFigure:BLUetooth:MEASurement1:MEValuation:MOEXception ONTurn On BT Meas On Exception. Results identified as faulty are never rejected.None
CONFigure:BLUetooth:MEASurement1:MEValuation:MOEXception OFFTurn Off BT Meas On Exception. Faulty results are rejected.None

Fetch (FETCh) (36)

CommandWhat it doesArguments
FETCh:SELFtest:STATe?Query Self Test State. Returns the self-test state (OFF, RUN, RDY).None
FETCh:GPRF:MEASurement1:POWer:STATe?Query Power Measurement State. Returns the GPRF power measurement state: OFF, RUN or RDY.None
FETCh:GPRF:MEASurement1:POWer:AVERage?Fetch Power Average. Returns the average RMS power results (one per segment) in dBm.None
FETCh:GPRF:MEASurement1:POWer:CURRent?Fetch Power Current. Returns the current RMS power results (one per segment) in dBm.None
FETCh:GPRF:MEASurement1:POWer:MAXimum:CURRent?Fetch Power Current Maximum. Returns the current-maximum power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:MINimum:CURRent?Fetch Power Current Minimum. Returns the current-minimum power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:PEAK:MAXimum?Fetch Power Peak Maximum. Returns the maximum peak power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:PEAK:MINimum?Fetch Power Peak Minimum. Returns the minimum peak power results in dBm.None
FETCh:GPRF:MEASurement1:POWer:SDEViation?Fetch Power Standard Deviation. Returns the standard deviation of the power results in dB.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:STATe?Query FFT Measurement State. Returns the FFT spectrum analyzer measurement state: OFF, RUN or RDY.None
FETCh:GPRF:MEASurement1:FFTSanalyzer:POWer:AVERage?Fetch FFT Power Average. Returns the average FFT spectrum trace (801 power values).None
FETCh:GPRF:MEASurement1:FFTSanalyzer:PEAKs:AVERage?Fetch FFT Peaks Average. Returns the peak search results (frequency, level pairs) of the average trace.None
FETCh:NRSub:MEASurement1:MEValuation:STATe?Query NR MultiEval State. Returns the NR FR1 multi-evaluation measurement state: OFF, RUN or RDY.None
FETCh:NRSub:MEASurement1:MEValuation:MODulation:AVERage?Fetch NR Modulation Average. Returns the average modulation results (EVM, magnitude/phase error, frequency error...).None
FETCh:NRSub:MEASurement1:MEValuation:TXPower:AVERage?Fetch NR TX Power Average. Returns the total TX power results.None
FETCh:NRSub:MEASurement1:MEValuation:ACLR:AVERage?Fetch NR ACLR Average. Returns the relative ACLR values.None
FETCh:NRSub:MEASurement1:MEValuation:SEMask:AVERage?Fetch NR Spectrum Emission Average. Returns the spectrum emission mask single-value results.None
FETCh:NRSub:MEASurement1:MEValuation:PMONitor:AVERage?Fetch NR Power Monitor Average. Returns the power monitor results.None
FETCh:NRSub:MEASurement1:MEValuation:ESFLatness:AVERage?Fetch NR Spectrum Flatness Average. Returns the equalizer spectrum flatness results.None
FETCh:NRSub:MEASurement1:MEValuation:IEMission:MARGin:AVERage?Fetch NR Inband Emission Margin. Returns the in-band emission limit margins.None
FETCh:LTE:MEASurement1:MEValuation:STATe?Query LTE MultiEval State. Returns the LTE multi-evaluation measurement state: OFF, RUN or RDY.None
FETCh:LTE:MEASurement1:MEValuation:MODulation:AVERage?Fetch LTE Modulation Average. Returns the average modulation single-value results.None
FETCh:LTE:MEASurement1:MEValuation:ACLR:AVERage?Fetch LTE ACLR Average. Returns the relative ACLR values.None
FETCh:LTE:MEASurement1:MEValuation:SEMask:AVERage?Fetch LTE Spectrum Emission Average. Returns the spectrum emission mask single-value results.None
FETCh:LTE:MEASurement1:MEValuation:PMONitor:AVERage?Fetch LTE Power Monitor Average. Returns the total TX power of all carriers.None
FETCh:WLAN:MEASurement1:MEValuation:STATe?Query WLAN MultiEval State. Returns the WLAN multi-evaluation measurement state: OFF, RUN or RDY.None
FETCh:WLAN:MEASurement1:MEValuation:MODulation:AVERage?Fetch WLAN Modulation Average. Returns the average OFDM modulation results (EVM, frequency/clock error, power...).None
FETCh:WLAN:MEASurement1:MEValuation:MODulation:CURRent?Fetch WLAN Modulation Current. Returns the current OFDM modulation results.None
FETCh:WLAN:MEASurement1:MEValuation:MODulation:DSSS:AVERage?Fetch WLAN DSSS Modulation Average. Returns the average DSSS (802.11b) modulation results.None
FETCh:WLAN:MEASurement1:MEValuation:TSMask:AVERage?Fetch WLAN Spectrum Mask Average. Returns the transmit spectrum mask margins.None
FETCh:WLAN:MEASurement1:MEValuation:SFLatness:AVERage?Fetch WLAN Spectral Flatness Average. Returns the spectral flatness margins.None
FETCh:BLUetooth:MEASurement1:MEValuation:STATe?Query BT MultiEval State. Returns the Bluetooth multi-evaluation measurement state: OFF, RUN or RDY.None
FETCh:BLUetooth:MEASurement1:MEValuation:MODulation:BRATe:AVERage?Fetch BT BR Modulation Average. Returns the average basic rate modulation results.None
FETCh:BLUetooth:MEASurement1:MEValuation:MODulation:LENergy:AVERage?Fetch BT LE Modulation Average. Returns the average LE 1M modulation results.None
FETCh:BLUetooth:MEASurement1:MEValuation:PVTime:BRATe:AVERage?Fetch BT BR Power Average. Returns the average basic rate power vs time results.None
FETCh:BLUetooth:MEASurement1:MEValuation:PVTime:LENergy:AVERage?Fetch BT LE Power Average. Returns the average LE 1M power vs time results.None

Source (SOURce) (35)

CommandWhat it doesArguments
SOURce:GPRF:GENerator1:STATe ONTurn On RF Generator. Turns the GPRF generator on.None
SOURce:GPRF:GENerator1:STATe OFFTurn Off RF Generator. Turns the GPRF generator off.None
SOURce:GPRF:GENerator1:STATe?Query RF Generator. Queries the generator state (OFF, PENDing, ON).None
SOURce:GPRF:GENerator1:BBMode <Mode>Set RF Generator Baseband Mode. Selects the generator baseband mode: unmodulated CW, dual tone or ARB waveform playback.Text: CW,DTONe,ARB
SOURce:GPRF:GENerator1:BBMode?Query RF Generator Baseband Mode. Reads the selected generator baseband mode: unmodulated CW, dual tone or ARB waveform playback.None
SOURce:GPRF:GENerator1:RFSettings:FREQuency <Frequency>Set RF Generator Frequency. Sets the frequency of the unmodulated RF carrier in Hz.Number
SOURce:GPRF:GENerator1:RFSettings:FREQuency?Query RF Generator Frequency. Reads the frequency of the unmodulated RF carrier in Hz.None
SOURce:GPRF:GENerator1:RFSettings:LEVel <Level>Set RF Generator Level. Sets the base RMS level of the RF generator in dBm.Number
SOURce:GPRF:GENerator1:RFSettings:LEVel?Query RF Generator Level. Reads the base RMS level of the RF generator in dBm.None
SOURce:GPRF:GENerator1:RFSettings:EATTenuation <Atten>Set RF Generator External Attenuation. Sets the external attenuation (or gain if negative) at the output connector in dB.Number
SOURce:GPRF:GENerator1:RFSettings:EATTenuation?Query RF Generator External Attenuation. Reads the external attenuation (or gain if negative) at the output connector in dB.None
SOURce:GPRF:GENerator1:RFSettings:DGAin <Gain>Set RF Generator Digital Gain. Sets the digital gain of the RF generator in dB.Number
SOURce:GPRF:GENerator1:RFSettings:DGAin?Query RF Generator Digital Gain. Reads the digital gain of the RF generator in dB.None
SOURce:GPRF:GENerator1:RFSettings:PEPower?Query RF Generator PEP. Queries the peak envelope power of the generated signal in dBm.None
SOURce:GPRF:GENerator1:ARB:FILE <Filename>Set ARB File. Selects the ARB waveform file (.wv) for ARB baseband mode.Text
SOURce:GPRF:GENerator1:ARB:FILE?Query ARB File. Reads the selected ARB waveform file (.wv) for ARB baseband mode.None
SOURce:GPRF:GENerator1:ARB:REPetition <Repetition>Set ARB Repetition. Selects continuous or single (counted cycles) ARB playback.Text: CONTinuous,SINGle
SOURce:GPRF:GENerator1:ARB:REPetition?Query ARB Repetition. Reads the selection: continuous or single (counted cycles) ARB playback.None
SOURce:GPRF:GENerator1:ARB:CYCLes <Cycles>Set ARB Cycles. Sets the number of ARB playback cycles in single repetition mode.Number
SOURce:GPRF:GENerator1:ARB:CYCLes?Query ARB Cycles. Reads the number of ARB playback cycles in single repetition mode.None
SOURce:GPRF:GENerator1:ARB:FOFFset <Offset>Set ARB Frequency Offset. Sets the baseband frequency offset for ARB playback in Hz.Number
SOURce:GPRF:GENerator1:ARB:FOFFset?Query ARB Frequency Offset. Reads the baseband frequency offset for ARB playback in Hz.None
SOURce:GPRF:GENerator1:ARB:CRATe?Query ARB Clock Rate. Queries the clock rate of the loaded waveform file in Hz.None
SOURce:GPRF:GENerator1:ARB:SAMPles?Query ARB Samples. Queries the number of samples in the loaded waveform file.None
SOURce:GPRF:GENerator1:ARB:POFFset?Query ARB Peak Offset. Queries the peak offset of the loaded waveform file in dB.None
SOURce:GPRF:GENerator1:ARB:LOFFset?Query ARB Level Offset. Queries the level offset (crest factor) of the loaded waveform file in dB.None
SOURce:GPRF:GENerator1:ARB:STATus?Query ARB Status. Queries the number of the ARB segment currently processed.None
SOURce:GPRF:GENerator1:DTONe:RATio <Ratio>Set Dual Tone Ratio. Sets the RMS level ratio between the two dual-tone signals in dB.Number
SOURce:GPRF:GENerator1:DTONe:RATio?Query Dual Tone Ratio. Reads the RMS level ratio between the two dual-tone signals in dB.None
SOURce:GPRF:GENerator1:DTONe:OFRequency1 <Offset>Set Dual Tone Offset Frequency 1. Sets the offset frequency of dual-tone source 1 relative to the RF frequency in Hz.Number
SOURce:GPRF:GENerator1:DTONe:OFRequency1?Query Dual Tone Offset Frequency 1. Reads the offset frequency of dual-tone source 1 relative to the RF frequency in Hz.None
SOURce:GPRF:GENerator1:DTONe:OFRequency2 <Offset>Set Dual Tone Offset Frequency 2. Sets the offset frequency of dual-tone source 2 relative to the RF frequency in Hz.Number
SOURce:GPRF:GENerator1:DTONe:OFRequency2?Query Dual Tone Offset Frequency 2. Reads the offset frequency of dual-tone source 2 relative to the RF frequency in Hz.None
SOURce:GPRF:GENerator1:DTONe:LEVel1?Query Dual Tone Level 1. Queries the output level of dual-tone source 1 in dBm.None
SOURce:GPRF:GENerator1:DTONe:LEVel2?Query Dual Tone Level 2. Queries the output level of dual-tone source 2 in dBm.None

System (SYSTem) (12)

CommandWhat it doesArguments
SYSTem:BASE:REFerence:FREQuency:SOURce <Source>Set Reference Frequency Source. Selects the reference frequency source: internal, external, or external with internal fallback.Text: INTernal,EXTernal,EINTernal
SYSTem:BASE:REFerence:FREQuency:SOURce?Query Reference Frequency Source. Reads the selected reference frequency source: internal, external, or external with internal fallback.None
SYSTem:BASE:OPTion:LIST?Query Installed Options. Returns the list of installed options, licenses and firmware applications.None
SYSTem:COMMunicate:NET:IPADdress?Query IP Address. Returns the IP address of the instrument LAN interface.None
SYSTem:GENerator:ALL:OFFAll Generators Off. Switches off all running generators.None
SYSTem:MEASurement:ALL:OFFAll Measurements Off. Switches off all running measurements.None
SYSTem:RESet:BASEReset Base Settings. Resets the base settings.None
SYSTem:RESet:ALLReset All Settings. Resets the base settings and all applications.None
SYSTem:PRESet:ALLPreset All Settings. Presets the base settings and all applications.None
SYSTem:ERRor:ALL?Read Error Queue. Returns all entries of the error queue and clears it.None
SYSTem:ERRor:COUNt?Read Error Count. Returns the number of entries in the error queue.None
SYSTem:VERSion?Read SCPI Version. Returns the SCPI version supported by the instrument.None

ROUT subsystem (12)

CommandWhat it doesArguments
ROUTe:GPRF:GENerator1:SPATh <Signal_Path>Set RF Generator Signal Path. Selects the RF connection (signal path name from the catalog) used for the generated signal.Text
ROUTe:GPRF:GENerator1:SPATh?Query RF Generator Signal Path. Reads the selected RF connection (signal path name from the catalog) used for the generated signal.None
ROUTe:GPRF:MEASurement1:SPATh <Signal_Path>Set Power Meter Signal Path. Selects the RF connection (signal path name from the catalog) used by the GPRF measurement.Text
ROUTe:GPRF:MEASurement1:SPATh?Query Power Meter Signal Path. Reads the selected RF connection (signal path name from the catalog) used by the GPRF measurement.None
ROUTe:NRSub:MEASurement1:SPATh <Signal_Path>Set NR Meas Signal Path. Selects the RF connection used by the NR FR1 measurement.Text
ROUTe:NRSub:MEASurement1:SPATh?Query NR Meas Signal Path. Reads the selected RF connection used by the NR FR1 measurement.None
ROUTe:LTE:MEASurement1:SPATh <Signal_Path>Set LTE Meas Signal Path. Selects the RF connection used by the LTE measurement.Text
ROUTe:LTE:MEASurement1:SPATh?Query LTE Meas Signal Path. Reads the selected RF connection used by the LTE measurement.None
ROUTe:WLAN:MEASurement1:SPATh <Signal_Path>Set WLAN Meas Signal Path. Selects the RF connection used by the WLAN measurement.Text
ROUTe:WLAN:MEASurement1:SPATh?Query WLAN Meas Signal Path. Reads the selected RF connection used by the WLAN measurement.None
ROUTe:BLUetooth:MEASurement1:SPATh <Signal_Path>Set BT Meas Signal Path. Selects the RF connection used by the Bluetooth measurement.Text
ROUTe:BLUetooth:MEASurement1:SPATh?Query BT Meas Signal Path. Reads the selected RF connection used by the Bluetooth measurement.None

Initiate (INITiate) (7)

CommandWhat it doesArguments
INIT:SELFtestStart Self Test. Starts the instrument self-test.None
INITiate:GPRF:MEASurement1:POWerStart Power Measurement. Starts or restarts the GPRF power measurement (state RUN).None
INITiate:GPRF:MEASurement1:FFTSanalyzerStart FFT Measurement. Starts or restarts the FFT spectrum analyzer measurement (state RUN).None
INITiate:NRSub:MEASurement1:MEValuationStart NR MultiEval. Starts or restarts the NR FR1 multi-evaluation measurement (state RUN).None
INITiate:LTE:MEASurement1:MEValuationStart LTE MultiEval. Starts or restarts the LTE multi-evaluation measurement (state RUN).None
INITiate:WLAN:MEASurement1:MEValuationStart WLAN MultiEval. Starts or restarts the WLAN multi-evaluation measurement (state RUN).None
INITiate:BLUetooth:MEASurement1:MEValuationStart BT MultiEval. Starts or restarts the Bluetooth multi-evaluation measurement (state RUN).None

Run control (6)

CommandWhat it doesArguments
STOP:GPRF:MEASurement1:POWerStop Power Measurement. Halts the GPRF power measurement; results are kept (state RDY).None
STOP:GPRF:MEASurement1:FFTSanalyzerStop FFT Measurement. Halts the FFT spectrum analyzer measurement; results are kept (state RDY).None
STOP:NRSub:MEASurement1:MEValuationStop NR MultiEval. Halts the NR FR1 multi-evaluation measurement; results are kept (state RDY).None
STOP:LTE:MEASurement1:MEValuationStop LTE MultiEval. Halts the LTE multi-evaluation measurement; results are kept (state RDY).None
STOP:WLAN:MEASurement1:MEValuationStop WLAN MultiEval. Halts the WLAN multi-evaluation measurement; results are kept (state RDY).None
STOP:BLUetooth:MEASurement1:MEValuationStop BT MultiEval. Halts the Bluetooth multi-evaluation measurement; results are kept (state RDY).None

Abort (6)

CommandWhat it doesArguments
ABORt:GPRF:MEASurement1:POWerAbort Power Measurement. Aborts the GPRF power measurement and releases resources (state OFF).None
ABORt:GPRF:MEASurement1:FFTSanalyzerAbort FFT Measurement. Aborts the FFT spectrum analyzer measurement and releases resources (state OFF).None
ABORt:NRSub:MEASurement1:MEValuationAbort NR MultiEval. Aborts the NR FR1 multi-evaluation measurement and releases resources (state OFF).None
ABORt:LTE:MEASurement1:MEValuationAbort LTE MultiEval. Aborts the LTE multi-evaluation measurement and releases resources (state OFF).None
ABORt:WLAN:MEASurement1:MEValuationAbort WLAN MultiEval. Aborts the WLAN multi-evaluation measurement and releases resources (state OFF).None
ABORt:BLUetooth:MEASurement1:MEValuationAbort BT MultiEval. Aborts the Bluetooth multi-evaluation measurement and releases resources (state OFF).None

CAT subsystem (5)

CommandWhat it doesArguments
CATalog:SYSTem:ATTenuation:CTABle?Query Correction Tables. Returns the names of all correction tables.None
CATalog:GPRF:GENerator1:SPATh?Query Generator Signal Paths. Returns the names of the available RF connections for the generator.None
CATalog:GPRF:MEASurement1:SPATh?Query Measurement Signal Paths. Returns the names of the available RF connections for the GPRF measurement.None
CATalog:TENVironment:SPATh?Query Test Environment Paths. Returns all connection (signal path) names defined in the test environment.None
CATalog:TENVironment:CONNectors?Query Test Environment Connectors. Returns the names of all RF connectors of the test environment.None

Sense (SENSe) (3)

CommandWhat it doesArguments
SENSe:BASE:REFerence:FREQuency:LOCKed?Query Reference Frequency Locked. Queries whether the reference frequency is locked.None
SENSe:BASE:TEMPerature:OPERating:INTernal?Query Internal Temperature. Queries the internal operating temperature in degrees C.None
SENSe:BASE:TEMPerature:OPERating:AMBient?Query Ambient Temperature. Queries the ambient temperature in degrees C.None

CRE subsystem (2)

CommandWhat it doesArguments
CREate:SYSTem:ATTenuation:CTABle <Table_Name>, <Freq_Att_Pairs>Create Correction Table. Creates a frequency-dependent attenuation table; pairs are <Frequency Hz>, <Attenuation dB>.Text; Text
CREate:TENVironment:SPATh <Signal_Path>, <Antenna_Name>, <Connector_Name>Create Signal Path. Creates a named connection between a DUT antenna name and an RF connector of the tester.Text; Text; Text

DEL subsystem (2)

CommandWhat it doesArguments
DELete:SYSTem:ATTenuation:CTABle <Table_Name>Delete Correction Table. Deletes a correction table.Text
DELete:TENVironment:SPATh <Signal_Path>Delete Signal Path. Deletes a named connection from the test environment.Text

ADD subsystem (2)

CommandWhat it doesArguments
ADD:TENVironment:SPATh:CTABle:RX <Signal_Path>, <Table_Name>Assign RX Correction Table. Assigns a correction table to the RX direction of a connection.Text; Text
ADD:TENVironment:SPATh:CTABle:TX <Signal_Path>, <Table_Name>Assign TX Correction Table. Assigns a correction table to the TX direction of a connection.Text; Text

Read (READ) (1)

CommandWhat it doesArguments
READ:GPRF:MEASurement1:POWer:AVERage?Measure Power Average. Starts a single-shot power measurement and returns the average RMS power in dBm.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (13)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*OPCSet Operation Complete Bit. Sets the operation complete bit in the event status register when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None
*ESR?Query Event Status Register. Returns and clears the standard event status register.None
*ESE <Mask>Set Event Status Enable. Sets the event status enable register (0 to 255).Number: 0,255
*STB?Query Status Byte. Returns the status byte.None
*SRE <Mask>Set Service Request Enable. Sets the service request enable register (0 to 255).Number: 0,255
*SAV <Memory>Save State. Stores the current settings in an intermediate memory.Number
*RCL <Memory>Recall State. Recalls settings from an intermediate memory.Number
*TRGTrigger Bus. Generates a software (bus) trigger event.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Rohde & Schwarz's programming documentation for the CMP180 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Rohde & Schwarz's programming manual: check it before you rely on an edge case. Last updated September 27, 2026.

Frequently asked questions

Does the Rohde & Schwarz CMP180 support SCPI remote control?

Yes. The Rohde & Schwarz CMP180 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 297 SCPI commands for it: 154 queries that read values or state, and 143 settings and actions.

How do I control the Rohde & Schwarz CMP180 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SOURce:GPRF:GENerator1:STATe ON and CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?.

Which command reads a value from the Rohde & Schwarz CMP180?

CONFigure:GPRF:MEASurement1:RFSettings:FREQuency? (query power meter frequency). Reads the center frequency of the RF analyzer in Hz. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Rohde & Schwarz CMP180 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Rohde & Schwarz CMP180 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today