The Keysight E5515C and E5515E radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 172 commands for it, 96 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the E5515C on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Keysight E5515C or E5515E and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Keysight E5515C's VISA address
# Paste the address of your Keysight E5515C (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("RFANalyzer:CONTrol:POWer:AUTO ON") # Turn On Analyzer Auto Power
print(inst.query("RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO?")) # Read Analyzer Auto Frequency State
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Keysight E5515C or E5515E and writes the report from the measured results.
Describe the test in a sentence, for example “turn on analyzer auto power on the E5515C, then read analyzer auto frequency state and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
172 commands in 15 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The E5515C and E5515E share this command set in TestFlow's library.
| Command | What it does | Arguments |
|---|---|---|
| CALL:OPERating:MODE <Mode> | Set Operating Mode. Sets the test set operating mode: Active Cell (CALL), GSM BCH or BCH+TCH test mode, GPRS BCH or BCH+PDTCH test mode, continuous wave (CW) or OFF. | Text: CALL,GBTest,GBTTest,PBTest,PBPTest,CW,OFF |
| CALL:OPERating:MODE? | Read Operating Mode. Reads the test set operating mode: Active Cell (CALL), GSM BCH or BCH+TCH test mode, GPRS BCH or BCH+PDTCH test mode, continuous wave (CW) or OFF. | None |
| CALL:CELL:BAND <Band> | Set Cell Band. Sets the band in which the broadcast channel (BCH) is transmitted. | Text: PGSM,EGSM,DCS,PCS,GSM450,GSM480,GSM750,GSM850,RGSM |
| CALL:CELL:BAND? | Read Cell Band. Reads the band in which the broadcast channel (BCH) is transmitted. | None |
| CALL:CELL:BCHannel:ARFCn <Channel> | Set BCH ARFCN. Sets the broadcast channel ARFCN for the selected broadcast band (e.g. PGSM 1-124, DCS 512-885, PCS 512-810, GSM850 128-251). | Number |
| CALL:CELL:BCHannel:ARFCn? | Read BCH ARFCN. Reads the broadcast channel ARFCN for the selected broadcast band (e.g. PGSM 1-124, DCS 512-885, PCS 512-810, GSM850 128-251). | None |
| CALL:CELL:BCHannel:SCELl <Cell> | Set Serving Cell. Sets what information is broadcast on the BCH (GSM, GPRS or EGPRS serving cell). | Text: GSM,GPRS,EGPRS |
| CALL:CELL:BCHannel:SCELl? | Read Serving Cell. Reads what information is broadcast on the BCH (GSM, GPRS or EGPRS serving cell). | None |
| CALL:CELL:POWer <Level> | Set Cell Power. Sets the cell (BCH) RF power in dBm for the selected format and turns the cell power state on. | Number |
| CALL:CELL:POWer? | Read Cell Power. Reads the cell (BCH) RF power in dBm for the selected format. | None |
| CALL:CELL:POWer:STATe ON | Turn On Cell Power. Turns the RF power of the cell on. | None |
| CALL:CELL:POWer:STATe OFF | Turn Off Cell Power. Turns the RF power of the cell off. | None |
| CALL:CELL:POWer:STATe? | Read Cell Power State. Reads the on/off state set by Turn_On_Cell_Power / Turn_Off_Cell_Power. | None |
| CALL:CELL:RFGenerator:FREQuency <Freq> | Set CW Generator Frequency. Sets the RF generator frequency in Hz used in CW operating mode (292 MHz to 2700 MHz). | Number |
| CALL:CELL:RFGenerator:FREQuency? | Read CW Generator Frequency. Reads the RF generator frequency in Hz used in CW operating mode (292 MHz to 2700 MHz). | None |
| CALL:CELL:MCCode <MCC> | Set Mobile Country Code. Sets the Mobile Country Code broadcast by the cell (0 to 999); cell operating mode must be OFF. | Number |
| CALL:CELL:MCCode? | Read Mobile Country Code. Reads the Mobile Country Code broadcast by the cell (0 to 999). | None |
| CALL:CELL:MNCode <MNC> | Set Mobile Network Code. Sets the Mobile Network Code broadcast by the cell (0 to 99); cell operating mode must be OFF. | Number |
| CALL:CELL:MNCode? | Read Mobile Network Code. Reads the Mobile Network Code broadcast by the cell (0 to 99). | None |
| CALL:CELL:LACode <LAC> | Set Location Area Code. Sets the cell Location Area Code (0 to 65535); cell operating mode must be OFF. | Number |
| CALL:CELL:LACode? | Read Location Area Code. Reads the cell Location Area Code (0 to 65535). | None |
| CALL:CELL:BCCode <BCC> | Set Base Station Colour Code. Sets the Base Station Colour Code (0 to 7); cell operating mode must be OFF. | Number: 0,1,2,3,4,5,6,7 |
| CALL:CELL:BCCode? | Read Base Station Colour Code. Reads the Base Station Colour Code (0 to 7). | None |
| CALL:CELL:NCCode <NCC> | Set Network Colour Code. Sets the Network Colour Code (0 to 7); cell operating mode must be OFF. | Number: 0,1,2,3,4,5,6,7 |
| CALL:CELL:NCCode? | Read Network Colour Code. Reads the Network Colour Code (0 to 7). | None |
| CALL:BURSt:TYPE <Burst> | Set Expected Burst. Sets the expected burst type used for measurement synchronization in test operating modes. | Text: RACH,TSC0,TSC1,TSC2,TSC3,TSC4,TSC5,TSC6,TSC7 |
| CALL:BURSt:TYPE? | Read Expected Burst. Reads the expected burst type used for measurement synchronization in test operating modes. | None |
| CALL:TCHannel:BAND <Band> | Set TCH Band. Sets the GSM band used by the BS emulator for the traffic channel (TCH). | Text: PGSM,EGSM,DCS,PCS,GSM450,GSM480,GSM750,GSM850,RGSM |
| CALL:TCHannel:BAND? | Read TCH Band. Reads the GSM band used by the BS emulator for the traffic channel (TCH). | None |
| CALL:TCHannel:ARFCn <Channel> | Set TCH ARFCN. Sets the downlink/uplink TCH channel number for the selected TCH band. | Number |
| CALL:TCHannel:ARFCn? | Read TCH ARFCN. Reads the downlink/uplink TCH channel number for the selected TCH band. | None |
| CALL:TCHannel:TSLot <Timeslot> | Set TCH Timeslot. Sets the timeslot used for the downlink and uplink traffic channel (1 to 7). | Number: 1,2,3,4,5,6,7 |
| CALL:TCHannel:TSLot? | Read TCH Timeslot. Reads the timeslot used for the downlink and uplink traffic channel (1 to 7). | None |
| CALL:TCHannel:CMODe <Mode> | Set TCH Channel Mode. Sets the speech channel mode: full rate, enhanced full rate or half rate speech. | Text: FRSPeech,EFRSpeech,HRSPeech |
| CALL:TCHannel:CMODe? | Read TCH Channel Mode. Reads the speech channel mode: full rate, enhanced full rate or half rate speech. | None |
| CALL:TCHannel:LOOPback <Loop> | Set TCH Loopback. Sets the MS traffic channel loopback type (A residual, B non-residual, C burst-by-burst) required for bit error measurements. | Text: OFF,A,B,C |
| CALL:TCHannel:LOOPback? | Read TCH Loopback. Reads the MS traffic channel loopback type (A residual, B non-residual, C burst-by-burst) required for bit error measurements. | None |
| CALL:TCHannel:DOWNlink:SPEech <Speech> | Set Downlink Speech. Sets the kind of speech data transmitted on the downlink TCH. | Text: ECHO,NONE,PRBS15,SIN300,SIN1000,SIN3000 |
| CALL:TCHannel:DOWNlink:SPEech? | Read Downlink Speech. Reads the kind of speech data transmitted on the downlink TCH. | None |
| CALL:TCHannel:POWer? | Read TCH Burst Power. Reads the downlink TCH used burst power amplitude in dB (0 to 30 dB). | None |
| CALL:MS:TXLevel <Level> | Set MS TX Level. Sets the mobile station uplink power control level for the selected band (0 to 31). | Number |
| CALL:MS:TXLevel? | Read MS TX Level. Reads the mobile station uplink power control level for the selected band (0 to 31). | None |
| CALL:MS:TADVance <TA> | Set MS Timing Advance. Sets the mobile station uplink TCH timing advance for the selected band (0 to 63). | Number |
| CALL:MS:TADVance? | Read MS Timing Advance. Reads the mobile station uplink TCH timing advance for the selected band (0 to 63). | None |
| CALL:MS:DTX:STATe ON | Turn On MS DTX. Enables discontinuous transmission (DTX) for the mobile station. | None |
| CALL:MS:DTX:STATe OFF | Turn Off MS DTX. Disables discontinuous transmission (DTX) for the mobile station. | None |
| CALL:MS:DTX:STATe? | Read MS DTX State. Reads the on/off state set by Turn_On_MS_DTX / Turn_Off_MS_DTX. | None |
| CALL:ORIGinate | Originate Call. Performs a base-station originated call to the mobile station. | None |
| CALL:END | End Call. Terminates the active voice or CSD call. | None |
| CALL:STATus:STATe? | Read Call Status. Reads the call status (IDLE / SREQ / ALER / CONN / DISC). | None |
| CALL:CONNected:STATe? | Read Call Connected. Returns 1 when the call is connected or 0 when idle; hangs during transitions until the timeout. | None |
| CALL:CONNected:ARM | Arm Call Connected Detector. Arms the call-state-change detector used with Read_Call_Connected for call synchronization. | None |
| CALL:CONNected:TIMeout <Seconds> | Set Call Connected Timeout. Sets the maximum time in seconds the test set waits for a hanging connected-state query to complete. | Number |
| CALL:CONNected:TIMeout? | Read Call Connected Timeout. Reads the maximum time in seconds the test set waits for a hanging connected-state query to complete. | None |
| CALL:ATTached:STATe? | Read Data Attached. Returns 1 if the GPRS data connection is in the attached state, otherwise 0. | None |
| CALL:PAGing:IMSI '<IMSI>' | Set Paging IMSI. Sets the IMSI used for paging the mobile station. | Text |
| CALL:PAGing:IMSI? | Read Paging IMSI. Reads the IMSI used for paging the mobile station. | None |
| CALL:MS:REPorted:IMSI? | Read MS IMSI. Reads the IMSI of the SIM reported by the mobile station. | None |
| CALL:MS:REPorted:IMEI? | Read MS IMEI. Reads the IMEI reported by the mobile equipment. | None |
| CALL:MS:REPorted:RXLevel? | Read MS Reported RX Level. Reads the TCH received level reported by the mobile (0 to 63, relative to -110 dBm). | None |
| CALL:MS:REPorted:RXQuality? | Read MS Reported RX Quality. Reads the received signal quality reported by the mobile (0 to 7). | None |
| CALL:MS:REPorted:TXLevel? | Read MS Reported TX Level. Reads the last transmit level reported by the mobile station (0 to 31). | None |
| CALL:MS:REPorted:TADVance? | Read MS Reported Timing Advance. Reads the last TCH timing advance used by the mobile station (0 to 63). | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:APPLication:SELect:NAME '<Application>' | Select Test Application. Selects the test application to run after reboot (name as shown in the Test Application Setup menu); the test set reboots in about 1 minute. | Text |
| SYSTem:APPLication:SELect:NAME? | Read Selected Test Application. Reads the test application that is selected and will run after the next reboot. | None |
| SYSTem:APPLication:CURRent:NAME? | Read Current Application Name. Reads the name of the test application currently running. | None |
| SYSTem:APPLication:CURRent:REVision? | Read Current Application Revision. Reads the revision of the test application currently running. | None |
| SYSTem:APPLication:CATalog:NAME? | Read Application Catalog. Reads the list of test applications installed in the test set. | None |
| SYSTem:APPLication:FORMat:NAME '<Format>' | Set Application Format. Switches between licensed formats of a fast switching or integrated test application (for example GSM or GPRS). | Text: GSM,GPRS |
| SYSTem:APPLication:FORMat:NAME? | Read Application Format. Reads the name of the currently active format. | None |
| SYSTem:CURRent:TA:NAME? | Read Current TA Name. Reads the name of the currently running test application. | None |
| SYSTem:CURRent:TA:MODel? | Read Current TA Model. Reads the model number of the currently running test application. | None |
| SYSTem:CORRection:FREQuency <Freq_List> | Set Amplitude Offset Frequencies. Sets up to 20 comma-separated frequencies for the RF IN/OUT amplitude offset table (Hz by default). | Text |
| SYSTem:CORRection:FREQuency? | Read Amplitude Offset Frequencies. Reads up to 20 comma-separated frequencies for the RF IN/OUT amplitude offset table (Hz by default). | None |
| SYSTem:CORRection:GAIN <Offset_List> | Set Amplitude Offset Gains. Sets up to 20 comma-separated amplitude offset values in dB paired with the offset frequencies. | Text |
| SYSTem:CORRection:GAIN? | Read Amplitude Offset Gains. Reads up to 20 comma-separated amplitude offset values in dB paired with the offset frequencies. | None |
| SYSTem:CORRection:STATe ON | Turn On Amplitude Offset. Turns the RF IN/OUT amplitude offset function on. | None |
| SYSTem:CORRection:STATe OFF | Turn Off Amplitude Offset. Turns the RF IN/OUT amplitude offset function off. | None |
| SYSTem:CORRection:STATe? | Read Amplitude Offset State. Reads the on/off state set by Turn_On_Amplitude_Offset / Turn_Off_Amplitude_Offset. | None |
| SYSTem:MEASurement:RESet | Reset Measurements. Aborts all measurements and clears results; continuous measurements restart. | None |
| SYSTem:PRESet2 | Full Preset. Performs a full preset of the test set (equivalent to SHIFT Preset). | None |
| SYSTem:PRESet3 | Partial Preset. Performs a partial preset: disconnects any call and aborts measurements without changing measurement settings. | None |
| SYSTem:ERRor? | Read Error. Reads and removes the oldest entry in the error queue. | None |
| SYSTem:ROSCillator:TIMebase? | Read Timebase Source. Reads whether the internal or an external 10 MHz reference drives the time base. | None |
| SYSTem:ROSCillator:LOCKed? | Read Timebase Locked. Reads whether the reference oscillator is locked (1) or unlocked (0). | None |
| SYSTem:COMMunicate:GPIB:SELF:ADDRess <Address> | Set GPIB Address. Sets the GPIB address of the test set (0 to 30). | Number |
| SYSTem:COMMunicate:GPIB:SELF:ADDRess? | Read GPIB Address. Reads the GPIB address of the test set (0 to 30). | None |
| SYSTem:COMMunicate:LAN:SELF:ADDRess <IP> | Set LAN IP Address. Sets the test set LAN IP address (string, e.g. '192.168.0.10'). | Text |
| SYSTem:COMMunicate:LAN:SELF:ADDRess? | Read LAN IP Address. Reads the test set LAN IP address (string, e.g. '192.168.0.10'). | None |
| SYSTem:BEEPer:STATe ON | Turn On Beeper. Turns the beeper on. | None |
| SYSTem:BEEPer:STATe OFF | Turn Off Beeper. Turns the beeper off. | None |
| SYSTem:BEEPer:STATe? | Read Beeper State. Reads the on/off state set by Turn_On_Beeper / Turn_Off_Beeper. | None |
| SYSTem:DATE? | Read System Date. Reads the system date. | None |
| SYSTem:TIME? | Read System Time. Reads the system time. | None |
| Command | What it does | Arguments |
|---|---|---|
| SETup:ALL:CONTinuous ON | Turn On All Continuous Trigger. Sets the trigger arm of all measurements to continuous. | None |
| SETup:ALL:CONTinuous OFF | Turn Off All Continuous Trigger. Sets the trigger arm of all measurements to single. | None |
| SETup:TXPower:CONTinuous ON | Turn On TX Power Continuous. Sets the TX power measurement trigger arm to continuous. | None |
| SETup:TXPower:CONTinuous OFF | Turn Off TX Power Continuous. Sets the TX power measurement trigger arm to single. | None |
| SETup:TXPower:COUNt <Count> | Set TX Power Count. Sets the TX power multi-measurement count (1 to 999) and turns the count state on. | Number |
| SETup:TXPower:COUNt? | Read TX Power Count. Reads the TX power multi-measurement count (1 to 999). | None |
| SETup:TXPower:TRIGger:SOURce <Source> | Set TX Power Trigger Source. Selects the TX power measurement trigger source. | Text: AUTO,PROTocol,RISE,IMMediate |
| SETup:TXPower:TRIGger:SOURce? | Read TX Power Trigger Source. Reads the TX power measurement trigger source. | None |
| SETup:TXPower:TIMeout <Seconds> | Set TX Power Timeout. Sets the TX power measurement timeout in seconds (0.1 to 999 s). | Number |
| SETup:TXPower:TIMeout? | Read TX Power Timeout. Reads the TX power measurement timeout in seconds (0.1 to 999 s). | None |
| SETup:PFERror:COUNt <Count> | Set PFER Count. Sets the phase and frequency error multi-measurement count (1 to 999). | Number |
| SETup:PFERror:COUNt? | Read PFER Count. Reads the phase and frequency error multi-measurement count (1 to 999). | None |
| SETup:PFERror:SYNC <Sync> | Set PFER Burst Sync. Sets the burst synchronization method for phase and frequency error. | Text: MIDamble,AMPLitude,NONE |
| SETup:PFERror:SYNC? | Read PFER Burst Sync. Reads the burst synchronization method for phase and frequency error. | None |
| SETup:PVTime:COUNt <Count> | Set PVT Count. Sets the power versus time multi-measurement count (1 to 999). | Number |
| SETup:PVTime:COUNt? | Read PVT Count. Reads the power versus time multi-measurement count (1 to 999). | None |
| SETup:PVTime:TIME <Offset_List> | Set PVT Time Offsets. Sets up to 12 comma-separated PvT time offsets (-50 us to 593 us) at which power is reported. | Text |
| SETup:PVTime:TIME? | Read PVT Time Offsets. Reads up to 12 comma-separated PvT time offsets (-50 us to 593 us) at which power is reported. | None |
| SETup:ORFSpectrum:MODulation:COUNt <Count> | Set ORFS Modulation Count. Sets the ORFS due to modulation multi-measurement count (1 to 999). | Number |
| SETup:ORFSpectrum:MODulation:COUNt? | Read ORFS Modulation Count. Reads the ORFS due to modulation multi-measurement count (1 to 999). | None |
| SETup:ORFSpectrum:MODulation:FREQuency <Offset_List> | Set ORFS Modulation Offsets. Sets the list of ORFS due to modulation frequency offsets (Hz by default). | Text |
| SETup:ORFSpectrum:MODulation:FREQuency? | Read ORFS Modulation Offsets. Reads the list of ORFS due to modulation frequency offsets (Hz by default). | None |
| SETup:ORFSpectrum:SWITching:FREQuency <Offset_List> | Set ORFS Switching Offsets. Sets up to 8 comma-separated ORFS due to switching frequency offsets (-1.8 MHz to -10 Hz and +10 Hz to +1.8 MHz). | Text |
| SETup:ORFSpectrum:SWITching:FREQuency? | Read ORFS Switching Offsets. Reads up to 8 comma-separated ORFS due to switching frequency offsets (-1.8 MHz to -10 Hz and +10 Hz to +1.8 MHz). | None |
| SETup:BERRor:TYPE <Type> | Set BER Type. Sets the bit error measurement type (Type IA/IB/II, residual or non-residual). | Text: TYPEIA,TYPEIB,TYPEII,RESTYPEIA,RESTYPEIB,RESTYPEII |
| SETup:BERRor:TYPE? | Read BER Type. Reads the bit error measurement type (Type IA/IB/II, residual or non-residual). | None |
| SETup:BERRor:COUNt <Bits> | Set BER Count. Sets the number of bits tested by the BER measurement (1 to 999000). | Number |
| SETup:BERRor:COUNt? | Read BER Count. Reads the number of bits tested by the BER measurement (1 to 999000). | None |
| Command | What it does | Arguments |
|---|---|---|
| FETCh:TXPower? | Fetch TX Power. Fetches the integrity indicator and average transmit power in dBm. | None |
| FETCh:TXPower:POWer:AVERage? | Fetch TX Power Average. Fetches the average TX power result in dBm. | None |
| FETCh:TXPower:POWer:MAXimum? | Fetch TX Power Maximum. Fetches the maximum TX power result in dBm. | None |
| FETCh:TXPower:POWer:MINimum? | Fetch TX Power Minimum. Fetches the minimum TX power result in dBm. | None |
| FETCh:TXPower:INTegrity? | Fetch TX Power Integrity. Fetches the TX power measurement integrity indicator (0 = normal). | None |
| FETCh:PFERror? | Fetch PFER. Fetches integrity, maximum RMS phase error, maximum peak phase error and worst frequency error. | None |
| FETCh:PFERror:RMS:MAXimum? | Fetch PFER RMS Phase Max. Fetches the maximum RMS phase error in degrees. | None |
| FETCh:PFERror:PEAK:MAXimum? | Fetch PFER Peak Phase Max. Fetches the maximum peak phase error in degrees. | None |
| FETCh:PFERror:FERRor:WORSt? | Fetch PFER Frequency Error Worst. Fetches the worst-case frequency error in Hz. | None |
| FETCh:PVTime:MASK? | Fetch PVT Mask. Fetches the power versus time mask pass/fail indicator (0 pass, 1 fail). | None |
| FETCh:PVTime:TXPower? | Fetch PVT TX Power. Fetches the average TX power result of the PvT measurement in dBm. | None |
| FETCh:ORFSpectrum:MODulation? | Fetch ORFS Modulation. Fetches the ORFS due to modulation results in dB. | None |
| FETCh:ORFSpectrum:SWITChing? | Fetch ORFS Switching. Fetches the ORFS due to switching results in dBm. | None |
| FETCh:BERRor? | Fetch BER. Fetches integrity, bits tested, bit error ratio and bit error count. | None |
| FETCh:BERRor:RATio? | Fetch BER Ratio. Fetches the bit error ratio in percent. | None |
| Command | What it does | Arguments |
|---|---|---|
| RFANalyzer:CONTrol:POWer:AUTO ON | Turn On Analyzer Auto Power. Sets the receiver expected power control to automatic. | None |
| RFANalyzer:CONTrol:POWer:AUTO OFF | Turn Off Analyzer Auto Power. Sets the receiver expected power control to manual. | None |
| RFANalyzer:CONTrol:POWer:AUTO? | Read Analyzer Auto Power State. Reads the on/off state set by Turn_On_Analyzer_Auto_Power / Turn_Off_Analyzer_Auto_Power. | None |
| RFANalyzer:CW:EXPected:POWer <Level> | Set CW Expected Power. Sets the power level in dBm the mobile is expected to transmit in CW mode (-60 to +53 dBm). | Number |
| RFANalyzer:CW:EXPected:POWer? | Read CW Expected Power. Reads the power level in dBm the mobile is expected to transmit in CW mode (-60 to +53 dBm). | None |
| RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO ON | Turn On Analyzer Auto Frequency. Sets the measuring receiver frequency control to automatic. | None |
| RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO OFF | Turn Off Analyzer Auto Frequency. Sets the measuring receiver frequency control to manual. | None |
| RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO? | Read Analyzer Auto Frequency State. Reads the on/off state set by Turn_On_Analyzer_Auto_Frequency / Turn_Off_Analyzer_Auto_Frequency. | None |
| RFANalyzer:MANual:MEASurement <Freq> | Set Analyzer Manual Frequency. Sets the measuring receiver frequency in Hz in manual mode (292.5 MHz to 2700 MHz). | Number |
| RFANalyzer:MANual:MEASurement? | Read Analyzer Manual Frequency. Reads the measuring receiver frequency in Hz in manual mode (292.5 MHz to 2700 MHz). | None |
| Command | What it does | Arguments |
|---|---|---|
| READ:TXPower? | Read TX Power. Initiates and fetches one TX power measurement (integrity indicator and average TX power in dBm). | None |
| READ:PFERror? | Read PFER. Initiates and fetches one phase/frequency error measurement (integrity, RMS phase, peak phase, worst frequency error). | None |
| READ:PVTime? | Read PVT. Initiates and fetches one power versus time measurement. | None |
| READ:ORFSpectrum? | Read ORFS. Initiates and fetches one output RF spectrum measurement. | None |
| READ:BERRor? | Read BER. Initiates and fetches one bit error measurement. | None |
| Command | What it does | Arguments |
|---|---|---|
| INITiate:<Measurement> | Initiate Measurement. Starts (activates) the selected measurement. | Text: TXPower,PFERror,PVTime,ORFSpectrum,BERRor,FBERror,DPOWer,ETXPower,IQTuning,AAUDio,DAUDio,SMONitor |
| INITiate:<Measurement>:OFF | Deactivate Measurement. Deactivates the selected measurement. | Text: TXPower,PFERror,PVTime,ORFSpectrum,BERRor,FBERror,DPOWer,ETXPower,IQTuning,AAUDio,DAUDio,SMONitor |
| INITiate:DONE? | Read Measurement Done. Returns the mnemonic of a measurement that has completed or timed out (NONE if none). | None |
| INITiate:ON? | Read Active Measurements. Returns the list of measurements that are currently ON. | None |
| Command | What it does | Arguments |
|---|---|---|
| RFGenerator:OUTPut <Port> | Set RF Output Port. Selects the RF generator output port: RF IN/OUT (IO) or RF OUT ONLY (OUT, requires the second RF output hardware). | Text: IO,OUT |
| RFGenerator:OUTPut? | Read RF Output Port. Reads the RF generator output port: RF IN/OUT (IO) or RF OUT ONLY (OUT, requires the second RF output hardware). | None |
| Command | What it does | Arguments |
|---|---|---|
| DISPlay:MODE <Mode> | Set Display Mode. Sets the display mode: FAST (display off for speed) or TRACK. | Text: FAST,TRACK |
| DISPlay:MODE? | Read Display Mode. Reads the display mode: FAST (display off for speed) or TRACK. | None |
| Command | What it does | Arguments |
|---|---|---|
| ABORt:ALL | Abort All Measurements. Stops all active measurements. | None |
| Command | What it does | Arguments |
|---|---|---|
| STATus:PRESet | Status Preset. Presets the status subsystem enable and transition registers. | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the identification string (manufacturer, model, serial number, 0). | None |
| *RST | Reset. Resets the test set to its default state. | None |
| *CLS | Clear Status. Clears the status registers and closes the error message screen. | None |
| *OPT? | Read Options. Returns the installed options. | None |
| *ESR? | Read Event Status. Reads and clears the standard event status register. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete before continuing. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Keysight's programming documentation for the E5515C and E5515E and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Keysight's programming manual: check it before you rely on an edge case. Last updated September 27, 2026.
Yes. The Keysight E5515C accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 172 SCPI commands for it: 96 queries that read values or state, and 76 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, RFANalyzer:CONTrol:POWer:AUTO ON and RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO?.
RFANalyzer:CONTrol:MEASurement:FREQuency:AUTO? (read analyzer auto frequency state). Reads the on/off state set by Turn_On_Analyzer_Auto_Frequency / Turn_Off_Analyzer_Auto_Frequency. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Keysight E5515C through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.