The Keysight E5505A phase noise analyzer is controlled remotely with SCPI commands. TestFlow's instrument library holds 138 commands for it, 28 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the E5505A on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Keysight E5505A and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Keysight E5505A's VISA address
# Paste the address of your Keysight E5505A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("SENSe:TSET:ATTenuator:AUTO ON") # Auto Attenuation On
print(inst.query("SENSe:RANGe:OFFSet?")) # Read Offset Range
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Keysight E5505A and writes the report from the measured results.
Describe the test in a sentence, for example “auto attenuation on on the E5505A, then read offset range and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
138 commands in 16 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| SENSe:NOISe:MEAStype <Type> | Set Measurement Type. Selects the measurement type (absolute / residual / FM discriminator / AM / baseband / not set). | Text: ABSolute,RESidual,FMDiscriminator,AM,BBANd,NOTSet |
| SENSe:RANGe:OFFSet <Start>,<Stop> | Set Offset Range. Sets the start and stop offset frequencies in Hz of the measurement range. | Number; Number |
| SENSe:RANGe:OFFSet? | Read Offset Range. Returns the start and stop offset frequencies of the measurement range. | None |
| SENSe:RANGe:FFT:SEGTable <Quality> | Set FFT Segment Table. Selects the FFT segment table used for the range. | Text: NORMal,FAST,HRESolution,CUSTom |
| SENSe:RANGe:SWEPt:SEGTable <Quality> | Set Swept Segment Table. Selects the swept segment table used for the range. | Text: NORMal,FAST,HRESolution,CUSTom |
| SENSe:RANGe:FFT:AVERage:MINimum <Count> | Set Min FFT Averages. Sets the minimum number of FFT averages for the measurement range. | Number |
| SENSe:NOISe:PULSed ON | Pulsed Mode On. Turns the source signal pulsed mode on. | None |
| SENSe:NOISe:PULSed OFF | Pulsed Mode Off. Turns the source signal pulsed mode off. | None |
| SENSe:NOISe:FFT <Mode> | Set FFT Mode. Selects extended or multiple time samples for the FFT analyzer. | Text: EXTended,MULTiple |
| SENSe:NOISe:QUADrature <Method> | Set Quadrature Method. Selects the quadrature method for residual measurements. | Text: PSHifter,SOURce |
| SENSe:NOISe:BBGain <Gain> | Set Baseband Gain. Sets the compensation in dB for an external amplifier gain. | Number |
| SENSe:DETector:SELect <Detector> | Set Detector Input. Selects the detector input. | Text: AUTO,EXTernal,LFRequency,HFRequency,UWAVe,TAM,TINoise,DCAM |
| SENSe:DETector:FREQuency <Frequency> | Set Detector Frequency. Sets the detector input frequency in Hz. | Number |
| SENSe:FFT:INPut:COUPling <Coupling> | Set FFT Coupling. Selects AC or DC coupling of the FFT analyzer input. | Text: AC,DC |
| SENSe:TSET:ATTenuator <Attenuation> | Set Input Attenuation. Sets the test set input attenuation in dB (0 to 35 in 5 dB steps). | Number: 0,5,10,15,20,25,30,35 |
| SENSe:TSET:ATTenuator:AUTO ON | Auto Attenuation On. Turns automatic autoranging of the test set input attenuator on. | None |
| SENSe:TSET:ATTenuator:AUTO OFF | Auto Attenuation Off. Turns automatic autoranging of the test set input attenuator off. | None |
| SENSe:TSET:LNAGain <Gain> | Set LNA Gain. Sets the nominal test set LNA gain in dB. | Number: 14,28,42,56 |
| SENSe:TSET:LNAGain:METHod <Method> | Set LNA Gain Method. Selects the method for applying LNA gain. | Text: AUTO,FIXed,PAUSe |
| SENSe:TSET:DCBLock ON | DC Block On. Turns the test set DC high-pass filter (DC block) on. | None |
| SENSe:TSET:DCBLock OFF | DC Block Off. Turns the test set DC high-pass filter (DC block) off. | None |
| SENSe:TSET:LPF <Frequency> | Set Input LPF. Sets the test set input LPF cutoff in Hz (20 kHz / 200 kHz / 2 MHz / 20 MHz / 100 MHz). | Number: 20000,200000,2000000,20000000,100000000 |
| SENSe:TSET:LPF:AUTO ON | Input LPF Auto On. Turns automatic selection of the test set LPF on. | None |
| SENSe:TSET:LPF:AUTO OFF | Input LPF Auto Off. Turns automatic selection of the test set LPF off. | None |
| SENSe:TSET:PLL:UNLock:IGNore ON | Ignore PLL Unlock On. Turns ignoring of PLL unlocked errors on. | None |
| SENSe:TSET:PLL:UNLock:IGNore OFF | Ignore PLL Unlock Off. Turns ignoring of PLL unlocked errors off. | None |
| SENSe:TVCO <Destination> | Set Tune Voltage Destination. Selects where the tune voltage output is connected. | Text: REFerence,CARRier,DCONverter,INTernal |
| SENSe:DCONverter:FREQuency <Frequency> | Set Downconverter Frequency. Sets the downconverter input frequency in Hz. | Number |
| SENSe:DCONverter:ATTenuator <Attenuation> | Set Downconverter Attenuation. Sets the downconverter attenuation in dB (0 to 35 in 5 dB steps). | Number: 0,5,10,15,20,25,30,35 |
| SENSe:DCONverter:ATTenuator:AUTO ON | Downconverter Auto Attenuation On. Turns automatic downconverter attenuation on. | None |
| SENSe:DCONverter:ATTenuator:AUTO OFF | Downconverter Auto Attenuation Off. Turns automatic downconverter attenuation off. | None |
| SENSe:DCONverter:IFGain <Gain> | Set Downconverter IF Gain. Sets the downconverter IF gain in dB (-10 to 45 in 5 dB steps). | Number: -10,45 |
| SENSe:DCONverter:IFGain:AUTO ON | Downconverter Auto IF Gain On. Turns automatic downconverter IF gain on. | None |
| SENSe:DCONverter:IFGain:AUTO OFF | Downconverter Auto IF Gain Off. Turns automatic downconverter IF gain off. | None |
| SENSe:DCONverter:BAND <Band> | Set Downconverter Band. Selects the downconverter band. | Text: UWAVe,A,K,Q,U,V,W |
| SENSe:DATA:HEADer:POINts? | Read Data Points. Returns the number of points returned by SENSe:DATA?. | None |
| SENSe:DATA? | Read Raw Data. Returns frequency, amplitude (dB/Hz) and spur flag triples of the raw S-phi data. | None |
| Command | What it does | Arguments |
|---|---|---|
| CALCulate:VIEW:XYData | Calc View XY Data. Sets CALCulate:DATA? to return frequency, amplitude and spur flag per point. | None |
| CALCulate:VIEW:SPURtable | Calc View Spur Table. Sets CALCulate:DATA? to return frequency and amplitude per spur. | None |
| CALCulate:VIEW:TRACe <Start>,<Stop>,<Points>,LOG | Calc View Trace Log. Sets CALCulate:DATA? to return the trace interpolated over the offset range in Hz with log point distribution. | Number; Number; Number |
| CALCulate:DATA:HEADer:POINts? | Read Calc Points. Returns the number of points returned by CALCulate:DATA?. | None |
| CALCulate:DATA? | Read Calc Data. Returns the processed data as selected by CALCulate:VIEW. | None |
| CALCulate:TRANsform <Transform> | Set Calc Transform. Selects the graph type transform for CALCulate:DATA? (L(f) / Sphi / Sv / Sy / 2-port NF / AM / baseband). | Text: SSBNoise,SDPF,SDFF,SFFF,NF2Port,AMNoise,BBAND |
| CALCulate:SELect <Data> | Set Calc Select. Selects which data set (noise / spurs / both) is returned and processed. | Text: BOTH,NOISe,SPURs |
| CALCulate:SMOothing <Value> | Set Calc Smoothing. Sets the degree of smoothing applied to returned data. | Number |
| CALCulate:YSHift <Value> | Set Calc Y Shift. Sets an amplitude shift in dB applied to CALCulate:DATA?. | Number |
| CALCulate:CFSCale <Value> | Set Carrier Scale. Sets the carrier frequency scale multiplier. | Number |
| CALCulate:DIPower <Power> | Set DUT Input Power. Sets the DUT input power adjustment. | Number |
| CALCulate:PBWidth <Value> | Set Power Bandwidth. Sets the power bandwidth adjustment. | Number |
| CALCulate:INTegral? <Start>,<Stop> | Measure Integral. Returns the trace integration between start and stop offset in Hz. | Number; Number |
| CALCulate:INTegral:TYPE <Type> | Set Integral Type. Selects normal or CCITT (ITU-T O.41) weighted integration. | Text: NORMal,CCITt |
| CALCulate:AVARiance? <Tau>,<Offset> | Measure Allan Variance. Returns the Allan variance for tau in s and the upper offset in Hz. | Number; Number |
| CALCulate:TVARiance? <Tau>,<Offset> | Measure Jitter. Returns the jitter (time variance) for tau in s and the upper offset in Hz. | Number; Number |
| CALCulate:ACCumulated? <Tau>,<Start>,<Stop> | Measure Accumulated Phase. Returns the accumulated phase noise integration (licensed option). | Number; Number; Number |
| CALCulate:LIMit:NOISe:MAXimum:DISPlay ON | Noise Max Limit Display On. Turns the display of the noise maximum limit line segments on. | None |
| CALCulate:LIMit:NOISe:MAXimum:DISPlay OFF | Noise Max Limit Display Off. Turns the display of the noise maximum limit line segments off. | None |
| CALCulate:LIMit:NOISe:MAXimum:FAIL:ALL? | Read Noise Max Limit Fail. Returns 1 if noise data exceeds the maximum limit in any segment (0 = pass). | None |
| CALCulate:LIMit:NOISe:MAXimum:FAIL? <Segment> | Read Noise Max Segment Fail. Returns the noise maximum limit result of one segment (0 = pass and 1 = fail). | Number: 1,100 |
| CALCulate:LIMit:NOISe:MAXimum:DELete:ALL | Delete Noise Max Limits. Deletes all noise maximum limit line segments. | None |
| CALCulate:LIMit:NOISe:MINimum:DISPlay ON | Noise Min Limit Display On. Turns the display of the noise minimum limit line segments on. | None |
| CALCulate:LIMit:NOISe:MINimum:DISPlay OFF | Noise Min Limit Display Off. Turns the display of the noise minimum limit line segments off. | None |
| CALCulate:LIMit:NOISe:MINimum:FAIL:ALL? | Read Noise Min Limit Fail. Returns 1 if noise data exceeds the minimum limit in any segment (0 = pass). | None |
| CALCulate:LIMit:NOISe:MINimum:FAIL? <Segment> | Read Noise Min Segment Fail. Returns the noise minimum limit result of one segment (0 = pass and 1 = fail). | Number: 1,100 |
| CALCulate:LIMit:NOISe:MINimum:DELete:ALL | Delete Noise Min Limits. Deletes all noise minimum limit line segments. | None |
| CALCulate:LIMit:SPUR:MAXimum:DISPlay ON | Spur Max Limit Display On. Turns the display of the spur maximum limit line segments on. | None |
| CALCulate:LIMit:SPUR:MAXimum:DISPlay OFF | Spur Max Limit Display Off. Turns the display of the spur maximum limit line segments off. | None |
| CALCulate:LIMit:SPUR:MAXimum:FAIL:ALL? | Read Spur Max Limit Fail. Returns 1 if spur data exceeds the maximum limit in any segment (0 = pass). | None |
| CALCulate:LIMit:SPUR:MAXimum:FAIL? <Segment> | Read Spur Max Segment Fail. Returns the spur maximum limit result of one segment (0 = pass and 1 = fail). | Number: 1,100 |
| CALCulate:LIMit:SPUR:MAXimum:DELete:ALL | Delete Spur Max Limits. Deletes all spur maximum limit line segments. | None |
| CALCulate:LIMit:SPUR:MINimum:DISPlay ON | Spur Min Limit Display On. Turns the display of the spur minimum limit line segments on. | None |
| CALCulate:LIMit:SPUR:MINimum:DISPlay OFF | Spur Min Limit Display Off. Turns the display of the spur minimum limit line segments off. | None |
| CALCulate:LIMit:SPUR:MINimum:FAIL:ALL? | Read Spur Min Limit Fail. Returns 1 if spur data exceeds the minimum limit in any segment (0 = pass). | None |
| CALCulate:LIMit:SPUR:MINimum:FAIL? <Segment> | Read Spur Min Segment Fail. Returns the spur minimum limit result of one segment (0 = pass and 1 = fail). | Number: 1,100 |
| CALCulate:LIMit:SPUR:MINimum:DELete:ALL | Delete Spur Min Limits. Deletes all spur minimum limit line segments. | None |
| Command | What it does | Arguments |
|---|---|---|
| CALibrate:DETector:CONStant:METHod <Method> | Set Detector Constant Method. Selects the method used to measure the phase detector constant. | Text: BEATnote,DCPeak,SSPur,DSPur,FMDeviation,AMINternal,PSHift,NONE |
| CALibrate:DETector:CONStant <Constant> | Set Detector Constant. Sets the phase detector constant in V/rad. | Number |
| CALibrate:DETector:CONStant? | Read Detector Constant. Returns the phase detector constant in V/rad. | None |
| CALibrate:VCO:PLLSuppress ON | PLL Suppression Verify On. Turns PLL suppression verification on. | None |
| CALibrate:VCO:PLLSuppress OFF | PLL Suppression Verify Off. Turns PLL suppression verification off. | None |
| CALibrate:VCO:PLLSuppress:ERRor:ACTion <Action> | Set PLL Error Action. Selects which PLL suppression curve is used when verification fails. | Text: THEoretical,ADJusted,PAUSe |
| CALibrate:VCO:TCONstant:METHod <Method> | Set Tune Constant Method. Selects the method used to determine the VCO tune constant. | Text: CURRent,MEASure,CALCulate |
| CALibrate:VCO:TCONstant:NOMinal <Constant> | Set Nominal Tune Constant. Sets the nominal VCO tune constant in Hz/V. | Number |
| CALibrate:VCO:TCONstant? | Read Tune Constant. Returns the VCO tune constant in Hz determined by calibration. | None |
| CALibrate:VCO:VCENter <Voltage> | Set VCO Center Voltage. Sets the VCO center tune voltage in V. | Number |
| CALibrate:VCO:VRANge <Voltage> | Set VCO Voltage Range. Sets the VCO tuning voltage range in V. | Number |
| CALibrate:VCO:PLLSuppress:CBWidth? | Read PLL Bandwidth. Returns the predicted phase lock loop bandwidth in Hz. | None |
| Command | What it does | Arguments |
|---|---|---|
| SOURce:CARRier:FREQuency <Frequency> | Set Carrier Frequency. Sets the carrier source frequency in Hz. | Number |
| SOURce:CARRier:FREQuency? | Read Carrier Frequency. Returns the carrier source frequency in Hz. | None |
| SOURce:CARRier:POWer <Power> | Set Carrier Power. Sets the carrier source power in dBm. | Number |
| SOURce:REFerence:POWer <Power> | Set Reference Power. Sets the reference source power in dBm. | Number |
| SOURce:REFerence:FREQuency:MULTiplier <Value> | Set Reference Multiplier. Sets the reference source frequency multiplier. | Number |
| SOURce:REFerence:FREQuency:DIVisor <Value> | Set Reference Divisor. Sets the reference source frequency divisor. | Number |
| SOURce:RESidual:FREQuency <Frequency> | Set Residual Frequency. Sets the residual source frequency in Hz. | Number |
| SOURce:RESidual:POWer <Power> | Set Residual Power. Sets the residual source power in dBm. | Number |
| SOURce:CALibration:FREQuency <Frequency> | Set Cal Source Frequency. Sets the calibration source frequency in Hz. | Number |
| SOURce:CALibration:POWer <Power> | Set Cal Source Power. Sets the calibration source power in dBm. | Number |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:GUI:REMote ON | GUI Remote On. Turns remote mode of the measurement client GUI on. | None |
| SYSTem:GUI:REMote OFF | GUI Remote Off. Turns remote mode of the measurement client GUI off. | None |
| SYSTem:GUI:LLOCkout | GUI Local Lockout. Disables the local menu function of the measurement client GUI. | None |
| SYSTem:PATH:CARRier <Port> | Set Carrier Path. Selects the input port the carrier signal is connected to. | Text: TSET,DCONverter |
| SYSTem:ASSet:CARRier <Asset> | Set Carrier Source Asset. Selects the carrier source asset ('None' or asset name in quotes). | Text |
| SYSTem:ASSet:REFerence <Asset> | Set Reference Source Asset. Selects the reference source asset ('None' or asset name in quotes). | Text |
| SYSTem:ASSet:FFT <Asset> | Set FFT Analyzer Asset. Selects the FFT analyzer asset ('None' or asset name in quotes). | Text |
| SYSTem:ASSet:TSET <Asset> | Set Test Set Asset. Selects the test set asset ('None' or asset name in quotes). | Text |
| SYSTem:ERRor? | Read Error. Returns the next error number and message from the error queue. | None |
| SYSTem:VERSion? | Read SCPI Version. Returns the SCPI version the system complies with. | None |
| Command | What it does | Arguments |
|---|---|---|
| PAUSe:ABORt:AUTO ON | Pause Auto Abort On. Turns automatic abort at pause points on. | None |
| PAUSe:ABORt:AUTO OFF | Pause Auto Abort Off. Turns automatic abort at pause points off. | None |
| PAUSe:CONNect ON | Connect Diagram On. Turns presentation of the connect diagram on. | None |
| PAUSe:CONNect OFF | Connect Diagram Off. Turns presentation of the connect diagram off. | None |
| PAUSe:CONTinue | Pause Continue. Continues from a pause point. | None |
| PAUSe:RETRy | Pause Retry. Retries the last operation prior to a pause point. | None |
| Command | What it does | Arguments |
|---|---|---|
| DISPlay:GRAPh:TRANsform <Transform> | Set Graph Transform. Selects the transform used to display data on the graph. | Text: SSBNoise,SDPF,SDFF,SFFF,NF2Port,AMNoise,BBAND |
| DISPlay:GRAPh:BOUNds:FREQuency <Min>,<Max> | Set Graph Frequency Bounds. Sets the graph x-axis offset frequency bounds in Hz. | Number; Number |
| DISPlay:GRAPh:BOUNds:AMPLitude <Transform>,<Min>,<Max> | Set Graph Amplitude Bounds. Sets the graph y-axis bounds for the given transform. | Text: SSBNoise,SDPF,SDFF,SFFF,NF2Port,AMNoise,BBAND; Number; Number |
| DISPlay:GRAPh:SMOothing <Value> | Set Graph Smoothing. Sets the smoothing of the displayed graph. | Number |
| DISPlay:TEXT:TITLe <Title> | Set Graph Title. Sets the graph title (string in quotes). | Text |
| DISPlay:MEASurement:TIMe? | Read Measurement Time. Returns the date, start time and stop time of the current measurement. | None |
| Command | What it does | Arguments |
|---|---|---|
| STATus:ADVise:ENABle ON | Advise Messages On. Turns reporting of server status messages in the error queue on. | None |
| STATus:ADVise:ENABle OFF | Advise Messages Off. Turns reporting of server status messages in the error queue off. | None |
| STATus:OPERation:CONDition? | Read Operation Condition. Returns the operation condition register (measurement state). | None |
| STATus:PRESet | Status Preset. Presets all SCPI status enable and transition registers. | None |
| Command | What it does | Arguments |
|---|---|---|
| INITiate:IMMediate:ALL | Start Cal And Measure. Initiates a system calibration and measurement (use *OPC/STATus:OPERation:CONDition? to detect completion). | None |
| INITiate:IMMediate:CALibrate | Start Calibration. Initiates a system calibration only. | None |
| INITiate:IMMediate:MEASure | Start Measurement. Initiates a measurement without calibration (repeat measurements). | None |
| Command | What it does | Arguments |
|---|---|---|
| MMEMory:LOAD <FileName> | Load Measurement File. Loads a measurement definition and data file (.pnm path string in quotes). | Text |
| MMEMory:STORe <FileName> | Save Measurement File. Stores the current measurement definition and data to a .pnm file (string in quotes). | Text |
| Command | What it does | Arguments |
|---|---|---|
| ABORt | Abort Measurement. Aborts the measurement in progress. | None |
| Command | What it does | Arguments |
|---|---|---|
| FORMat:DATA ASCii,<Digits> | Set Data Format. Selects ASCII transfer with the given number of significant digits. | Number |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the system identification string. | None |
| *RST | Reset. Resets the measurement definition to defaults (equivalent to File > New). | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *TST? | Self Test. Runs the self-test and returns the result. | None |
| *OPC? | Operation Complete. Returns 1 when pending INITiate operations are complete. | None |
| *WAI | Wait To Continue. Waits until pending INITiate operations are complete before continuing. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Keysight's programming documentation for the E5505A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Keysight's programming manual: check it before you rely on an edge case. Last updated September 26, 2026.
Yes. The Keysight E5505A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 138 SCPI commands for it: 28 queries that read values or state, and 110 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SENSe:TSET:ATTenuator:AUTO ON and SENSe:RANGe:OFFSet?.
SENSe:RANGe:OFFSet? (read offset range). Returns the start and stop offset frequencies of the measurement range. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Keysight E5505A through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.