Vector Network Analyzer · SCPI command reference

Keysight E5061B SCPI commands

The Keysight E5061B vector network analyzer is controlled remotely with SCPI commands. TestFlow's instrument library holds 58 commands for it, 14 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the E5061B on a real bench.

Commands
58
Queries
14
Subsystems
13
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Keysight E5061B and writes the report from the measured results.

Get started

Control the Keysight E5061B from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Keysight E5061B's VISA address

# Paste the address of your Keysight E5061B (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("OUTPut:STATe ON")  # RF Power On
print(inst.query("SENSe:FREQuency:STARt?"))  # Read Start Freq

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Keysight E5061B and writes the report from the measured results.

Get started

Run a E5061B test without writing code

Describe the test in a sentence, for example “rf power on on the E5061B, then read start freq and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

58 commands in 13 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Sense (SENSe) (19)

CommandWhat it doesArguments
SENSe:FREQuency:STARt <Frequency>Set Start Freq. Sets the sweep start frequency in Hz.Number
SENSe:FREQuency:STOP <Frequency>Set Stop Freq. Sets the sweep stop frequency in Hz.Number
SENSe:FREQuency:CENTer <Frequency>Set Center Freq. Sets the sweep center frequency in Hz.Number
SENSe:FREQuency:SPAN <Frequency>Set Span Freq. Sets the sweep frequency span in Hz.Number
SENSe:FREQuency:CW <Frequency>Set CW Freq. Sets the CW (fixed) frequency in Hz, used in CW/power sweep modes.Number
SENSe:FREQuency:STARt?Read Start Freq. Returns the current start frequency in Hz.None
SENSe:FREQuency:STOP?Read Stop Freq. Returns the current stop frequency in Hz.None
SENSe:SWEep:POINts <Points>Set Points. Sets the number of measurement points per sweep.Number
SENSe:SWEep:POINts?Read Points. Returns the number of measurement points per sweep.None
SENSe:SWEep:TYPE <Type>Set Sweep Type. Sets the sweep type (linear, log, segment, power, or CW).Text: LINear,LOGarithmic,SEGMent,POWer,BIAS
SENSe:SWEep:TIME <Seconds>Set Sweep Time. Sets the sweep time in seconds.Number
SENSe:BANDwidth <Bandwidth>Set IF Bandwidth. Sets the IF (resolution) bandwidth in Hz.Number
SENSe:BANDwidth?Read IF Bandwidth. Returns the current IF bandwidth in Hz.None
SENSe:AVERage:STATe ONAverage On. Enables trace averaging.None
SENSe:AVERage:STATe OFFAverage Off. Disables trace averaging.None
SENSe:AVERage:COUNt <Count>Set Average Count. Sets the number of sweeps to average.Number
SENSe:AVERage:CLEarAverage Clear. Restarts (clears) the averaging measurement.None
SENSe:CORRection:STATe ONCorrection On. Turns measurement error correction (calibration) on.None
SENSe:CORRection:STATe OFFCorrection Off. Turns measurement error correction (calibration) off.None

Calculate (CALCulate) (13)

CommandWhat it doesArguments
CALCulate:PARameter<Trace>:DEFine <Parameter>Define Measurement. Creates a new measurement trace with the given name and S-parameter.Number: 1-4; Text: S11,S21,S12,S22,A,B,R1,R2,TR,T,R
CALCulate:PARameter<Number>:SELectSelect By Number. Selects the active measurement by its trace number.Number: 1-4
CALCulate:FORMat <Format>Set Format. Sets the display/data format for the selected trace.Text: MLOGarithmic,MLINear,PHASe,UPHase,SMITh,POLar,SWR,GDELay,REAL,IMAGinary
CALCulate:FORMat?Read Format. Returns the display/data format of the selected trace.None
CALCulate:DATA:FDATa?Read Formatted Data. Returns the formatted trace data array for the selected measurement.None
CALCulate:DATA:SDATa?Read Complex Data. Returns the corrected complex (real/imag) trace data array.None
CALCulate:MARKer<Marker>:STATe ONMarker On. Turns on the specified marker on the active trace.Number: 1,2,3,4,5,6,7,8,9,10
CALCulate:MARKer<Marker>:STATe OFFMarker Off. Turns off the specified marker on the active trace.Number: 1,2,3,4,5,6,7,8,9,10
CALCulate:MARKer<Marker>:X <Frequency>Set Marker X. Sets the stimulus (X) position of the marker in Hz.Number: 1,2,3,4,5,6,7,8,9,10; Number
CALCulate:MARKer<Marker>:X?Read Marker X. Returns the stimulus (X) position of the marker.Number: 1,2,3,4,5,6,7,8,9,10
CALCulate:MARKer<Marker>:Y?Read Marker Y. Returns the response (Y) value at the marker.Number: 1,2,3,4,5,6,7,8,9,10
CALCulate:MARKer<Marker>:FUNCtion:TYPE MAXimum;:CALCulate:MARKer<Marker>:FUNCtion:EXECuteMarker Search Max. Moves the marker to the trace maximum.Number: 1-10
CALCulate:MARKer<Marker>:FUNCtion:TYPE MINimum;:CALCulate:MARKer<Marker>:FUNCtion:EXECuteMarker Search Min. Moves the marker to the trace minimum.Number: 1-10

Initiate (INITiate) (3)

CommandWhat it doesArguments
INITiate:CONTinuous ONContinuous On. Enables continuous (free-run) triggering.None
INITiate:CONTinuous OFFContinuous Off. Disables continuous triggering (hold/single mode).None
INITiate:IMMediateTrigger Single. Triggers a single sweep when not in continuous mode.None

Display (DISPlay) (3)

CommandWhat it doesArguments
DISPlay:WINDow:TRACe:Y:SCALe:AUTOAutoscale. Autoscales the active trace to fit the display.None
DISPlay:WINDow:TRACe:Y:SCALe:PDIVision <Per_Div>Set Y Scale. Sets the vertical scale per division for the active trace.Number
DISPlay:WINDow:TRACe:Y:SCALe:RLEVel <Level>Set Ref Level. Sets the reference level for the active trace.Number

Mass memory (MMEMory) (3)

CommandWhat it doesArguments
MMEMory:STORe '<Filename>'Save State. Saves the instrument state/data to the named file.Text
MMEMory:LOAD '<Filename>'Recall State. Recalls an instrument state from the named file.Text
MMEMory:STORe:IMAGe '<Filename>'Save Screenshot. Saves a screenshot image to the named file.Text

Source (SOURce) (2)

CommandWhat it doesArguments
SOURce:POWer <Power>Set Power Level. Sets the source output power level in dBm.Number
SOURce:POWer?Read Power Level. Returns the source output power level in dBm.None

Output (OUTPut) (2)

CommandWhat it doesArguments
OUTPut:STATe ONRF Power On. Turns the RF source power output on.None
OUTPut:STATe OFFRF Power Off. Turns the RF source power output off.None

System (SYSTem) (2)

CommandWhat it doesArguments
SYSTem:PRESetPreset. Presets the analyzer to its default measurement state.None
SYSTem:ERRor?Read Error. Reads the next message from the error queue.None

Trigger (TRIGger) (1)

CommandWhat it doesArguments
TRIGger:SOURce <Source>Set Trigger Source. Sets the trigger source for the sweep.Text: INTernal,EXTernal,MANual,BUS

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (7)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass or 1 for failure.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None
*TRGTrigger Bus. Generates a bus trigger when the instrument is in wait-for-trigger state.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Keysight's programming documentation for the E5061B and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Keysight's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.

Frequently asked questions

Does the Keysight E5061B support SCPI remote control?

Yes. The Keysight E5061B accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 58 SCPI commands for it: 14 queries that read values or state, and 44 settings and actions.

How do I control the Keysight E5061B from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut:STATe ON and SENSe:FREQuency:STARt?.

Which command reads a value from the Keysight E5061B?

SENSe:FREQuency:STARt? (read start freq). Returns the current start frequency in Hz. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Keysight E5061B without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Keysight E5061B through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today