In TestFlow's instrument library, the Keysight E7515B takes 109 SCPI commands, 15 of them queries, and the Rohde & Schwarz CMW500 takes 300 SCPI commands, 157 of them queries. That is 191 more on the CMW500. Counting distinct command headers (the command path without its arguments), 2 are accepted by both, 93 exist only on the E7515B, and 283 only on the CMW500. 2% of the E7515B's command headers also exist on the CMW500.
Both libraries have commands under SYSTem. Only the E7515B has BSE and DISPlay. Only the CMW500 has CONFigure, SOURce, FETCh, READ, ROUTe, and INITiate and 5 more.
Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?.
TestFlow's library gives the E7515P and E7515R the same command set as the E7515B, so the E7515B column applies to them too.
Describe the test; TestFlow's agent uses these command sets to drive your Keysight E7515B or Rohde & Schwarz CMW500 and writes the report from the measured results.
Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.
| Keysight E7515B | Rohde & Schwarz CMW500 | |
|---|---|---|
| Commands in TestFlow's library | 109 | 300 |
| Queries (read a value or state) | 15 | 157 |
| Settings and actions | 94 | 143 |
| Subsystems | 7 | 16 |
| Distinct command headers | 95 | 285 |
| Headers the other lacks | 93 | 283 |
| Command language | SCPI | SCPI |
| Operation complete | *OPC? | *OPC? |
| Error queue | SYSTem:ERRor? | SYSTem:ERRor? |
| Models on this command set | E7515B, E7515P, E7515R | CMW500 |
2 command headers are in both libraries.
| Command | What it does |
|---|---|
| *IDN? | Identify. Returns the test application identification string. |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. |
93 command headers in the E7515B library have no match in the CMW500 library. Below are 9 of them from the 3 largest subsystems; the full list is in the Keysight E7515B command reference.
| Command | What it does |
|---|---|
| BSE:SELected:CELL <RAT>,<Cell> | Select Cell. Selects the active cell shown/controlled in the test application. |
| BSE:CONFig:<RAT>:CELL:COUNt? | Read Cell Count. Returns the number of LTE or NR cells supported by the current configuration. |
| BSE:CONFig:<RAT>:<Cell>:ACTive:STATe 1 | Turn On Cell. Turns the selected LTE or NR cell on. |
| BSE:CONFig:<RAT>:<Cell>:ACTive:STATe? | Read Cell Active State. Returns 1 if the cell is on, 0 if off. |
| Command | What it does |
|---|---|
| SYSTem:PRESet:FULL | Full Preset. Performs a full preset of the UXM 5G test application settings. |
| SYSTem:SCPI:IMPort '<File>' | Import SCPI File. Imports and runs a saved SCPI configuration file in the test application. |
| SYSTem:SCPI:IMPort:STATus? | Read SCPI Import Status. Returns 1 while a SCPI file import is still in progress, 0 when finished. |
| SYSTem:IMS:SERVer:UE:DERegister | IMS Deregister UE. De-registers the UE from the internal IMS server. |
| Command | What it does |
|---|---|
| DISPlay:<RAT> <Tab>,<Subtab> | Select Display Tab. Selects the display tab and sub-tab (e.g. PHY,PDSCH or BTHR,SUMMARY) for the selected cell. |
283 command headers in the CMW500 library have no match in the E7515B library. Below are 24 of them from the 6 largest subsystems; the full list is in the Rohde & Schwarz CMW500 command reference.
| Command | What it does |
|---|---|
| CONFigure:GPRF:MEASurement1:RFSettings:FREQuency <Freq> | Set Analyzer Frequency. Sets the center frequency of the RF analyzer in Hz. |
| CONFigure:GPRF:MEASurement1:RFSettings:FREQuency? | Read Analyzer Frequency. Reads the center frequency of the RF analyzer in Hz. |
| CONFigure:GPRF:MEASurement1:RFSettings:ENPower <Power> | Set Analyzer Expected Power. Sets the expected nominal power of the measured RF signal in dBm. |
| CONFigure:GPRF:MEASurement1:RFSettings:ENPower? | Read Analyzer Expected Power. Reads the expected nominal power of the measured RF signal in dBm. |
| Command | What it does |
|---|---|
| SOURce:GPRF:GENerator1:STATe ON | Turn On Generator. Turns the GPRF RF generator on. |
| SOURce:GPRF:GENerator1:STATe? | Read Generator State. Reads the generator state (OFF / PENDing / ON / RDY). |
| SOURce:GPRF:GENerator1:STATe:ALL? | Read Generator State All. Reads detailed generator state information including the main state and the synchronization state. |
| SOURce:GPRF:GENerator1:BBMode <Mode> | Set Generator Baseband Mode. Selects the baseband mode of the generator signal: unmodulated CW, dual tone, or ARB waveform playback. |
| Command | What it does |
|---|---|
| FETCh:GPRF:MEASurement1:POWer:STATe? | Read Power Measurement State. Reads the main state of the power measurement (OFF / RUN / RDY). |
| FETCh:GPRF:MEASurement1:POWer:STATe:ALL? | Read Power Measurement State All. Reads the detailed power measurement state including the main state and the synchronization state. |
| FETCh:GPRF:MEASurement1:POWer:CURRent? | Fetch Power Current. Fetches the current power results of all measured segments in dBm without restarting the measurement. |
| FETCh:GPRF:MEASurement1:POWer:CURRent:RMS? | Fetch Power Current RMS. Fetches the current RMS power results in dBm. |
| Command | What it does |
|---|---|
| SYSTem:BASE:REFerence:FREQuency:SOURce <Source> | Set Reference Frequency Source. Selects the internal or an external reference frequency source for the instrument. |
| SYSTem:BASE:REFerence:FREQuency:SOURce? | Read Reference Frequency Source. Reads the selected reference frequency source. |
| SYSTem:BASE:REFerence:FREQuency <Freq> | Set External Reference Frequency. Sets the expected external reference frequency in Hz when the external reference source is selected. |
| SYSTem:BASE:REFerence:FREQuency? | Read External Reference Frequency. Reads the expected external reference frequency in Hz. |
| Command | What it does |
|---|---|
| READ:GPRF:MEASurement1:POWer:CURRent? | Read Power Current. Starts the measurement and returns the current power results of all measured segments in dBm. |
| READ:GPRF:MEASurement1:POWer:CURRent:RMS? | Read Power Current RMS. Starts the measurement and returns the current RMS power results in dBm. |
| READ:GPRF:MEASurement1:POWer:AVERage? | Read Power Average. Starts the measurement and returns the average power results of all measured segments in dBm. |
| READ:GPRF:MEASurement1:POWer:SDEViation? | Read Power Standard Deviation. Starts the measurement and returns the standard deviation of the power results in dB. |
| Command | What it does |
|---|---|
| ABORt:GPRF:MEASurement1:POWer | Abort Power Measurement. Halts the power measurement and puts it into the OFF state; all results are set to NAV. |
| ABORt:GPRF:MEASurement1:FFTSanalyzer | Abort FFT Measurement. Halts the FFT measurement and clears all results. |
| ABORt:GPRF:MEASurement1:SPECtrum | Abort Spectrum Measurement. Halts the spectrum measurement and clears all results. |
| ABORt:GPRF:MEASurement1:IQVSlot | Abort IQVSlot Measurement. Halts the I/Q vs slot measurement and clears all results. |
With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, the two libraries have no common command with a worked example on both, so each instrument uses its own: BSE:CONFig:NR5G:PHY:OPTimize:CONTiguous:STATe 1 on the E7515B and SOURce:GPRF:GENerator1:STATe ON on the CMW500. For the reading, the two libraries have no common command with a worked example on both, so each instrument uses its own: BSE:MEASure:NR5G:CELL1:L1:RSRPower:STATe? on the E7515B and CONFigure:GPRF:MEASurement1:RFSettings:FREQuency? on the CMW500. For the basics, see the PyVISA tutorial.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find both VISA addresses
a = rm.open_resource("PASTE_E7515B_ADDRESS") # Keysight E7515B
b = rm.open_resource("PASTE_CMW500_ADDRESS") # Rohde & Schwarz CMW500
for inst in (a, b):
inst.timeout = 5000 # ms
print(inst.query("*IDN?"))
# No shared setting with an example on both, so each uses its own command
a.write("BSE:CONFig:NR5G:PHY:OPTimize:CONTiguous:STATe 1") # Turn On NR Contiguous Optimization
b.write("SOURce:GPRF:GENerator1:STATe ON") # Turn On Generator
# No shared reading with an example on both, so each uses its own command
print(a.query("BSE:MEASure:NR5G:CELL1:L1:RSRPower:STATe?")) # Read NR RSRP Measurement State
print(b.query("CONFigure:GPRF:MEASurement1:RFSettings:FREQuency?")) # Read Analyzer Frequency
a.close()
b.close()Describe the test; TestFlow's agent uses these command sets to drive your Keysight E7515B or Rohde & Schwarz CMW500 and writes the report from the measured results.
In TestFlow's library the E7515B has 109 SCPI commands and the CMW500 has 300 SCPI commands. 2 command headers are common to both, 93 are only on the E7515B (mostly BSE and SYSTem), and 283 are only on the CMW500 (mostly CONFigure and SOURce).
Partly. 2 command headers are accepted by both. 376 are not, for example BSE:SELected:CELL on the E7515B and CONFigure:GPRF:MEASurement1:RFSettings:FREQuency on the CMW500, so a script that uses those needs a separate branch for each instrument.
The CMW500: 109 commands for the E7515B against 300 for the CMW500 in TestFlow's library. Of those, 15 on the E7515B and 157 on the CMW500 are queries that read a value or state, and the library splits them into 7 and 16 subsystems.
Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?. Each command named here is listed in the tables on this page and on each instrument's command reference.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.