Radio Test Set · SCPI command comparison

Keysight E7515B vs Rohde & Schwarz CMX500: SCPI commands and remote control compared

In TestFlow's instrument library, the Keysight E7515B takes 109 SCPI commands, 15 of them queries, and the Rohde & Schwarz CMX500 takes 266 SCPI commands, 104 of them queries. That is 157 more on the CMX500. Counting distinct command headers (the command path without its arguments), 3 are accepted by both, 92 exist only on the E7515B, and 238 only on the CMX500. 3% of the E7515B's command headers also exist on the CMX500.

Both libraries have commands under SYSTem. Only the E7515B has BSE and DISPlay. Only the CMX500 has CONFigure, FETCh, SOURce, CATalog, CREate, and PROCedure and 10 more.

Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?.

TestFlow's library gives the E7515P and E7515R the same command set as the E7515B, so the E7515B column applies to them too.

E7515B commands
109
CMX500 commands
266
Shared headers
3
Unique headers
330

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Keysight E7515B or Rohde & Schwarz CMX500 and writes the report from the measured results.

Get started

E7515B vs CMX500 at a glance

Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.

Keysight E7515BRohde & Schwarz CMX500
Commands in TestFlow's library109266
Queries (read a value or state)15104
Settings and actions94162
Subsystems721
Distinct command headers95241
Headers the other lacks92238
Command languageSCPISCPI
Operation complete*OPC?*OPC?
Error queueSYSTem:ERRor?SYSTem:ERRor?
Models on this command setE7515B, E7515P, E7515RCMX500

Commands both accept

3 command headers are in both libraries.

CommandWhat it does
SYSTem:ERRor?Read Error. Reads and removes the oldest entry in the error queue.
*IDN?Identify. Returns the test application identification string.
*OPC?Operation Complete. Returns 1 when all pending operations are complete.

Only on the Keysight E7515B

92 command headers in the E7515B library have no match in the CMX500 library. Below are 9 of them from the 3 largest subsystems; the full list is in the Keysight E7515B command reference.

BSE (87 only on the E7515B)

CommandWhat it does
BSE:SELected:CELL <RAT>,<Cell>Select Cell. Selects the active cell shown/controlled in the test application.
BSE:CONFig:<RAT>:CELL:COUNt?Read Cell Count. Returns the number of LTE or NR cells supported by the current configuration.
BSE:CONFig:<RAT>:<Cell>:ACTive:STATe 1Turn On Cell. Turns the selected LTE or NR cell on.
BSE:CONFig:<RAT>:<Cell>:ACTive:STATe?Read Cell Active State. Returns 1 if the cell is on, 0 if off.

SYSTem (4 only on the E7515B)

CommandWhat it does
SYSTem:PRESet:FULLFull Preset. Performs a full preset of the UXM 5G test application settings.
SYSTem:SCPI:IMPort '<File>'Import SCPI File. Imports and runs a saved SCPI configuration file in the test application.
SYSTem:SCPI:IMPort:STATus?Read SCPI Import Status. Returns 1 while a SCPI file import is still in progress, 0 when finished.
SYSTem:IMS:SERVer:UE:DERegisterIMS Deregister UE. De-registers the UE from the internal IMS server.

DISPlay (1 only on the E7515B)

CommandWhat it does
DISPlay:<RAT> <Tab>,<Subtab>Select Display Tab. Selects the display tab and sub-tab (e.g. PHY,PDSCH or BTHR,SUMMARY) for the selected cell.

Only on the Rohde & Schwarz CMX500

238 command headers in the CMX500 library have no match in the E7515B library. Below are 24 of them from the 6 largest subsystems; the full list is in the Rohde & Schwarz CMX500 command reference.

CONFigure (122 only on the CMX500)

CommandWhat it does
CONFigure:SIGNaling:TOPology:PLMN:MCC <PLMN_Name>, <MCC>Set PLMN MCC. Configures the mobile country code (MCC) of the selected PLMN.
CONFigure:SIGNaling:TOPology:PLMN:MCC? <PLMN_Name>Query PLMN MCC. Queries the mobile country code (MCC) of the selected PLMN.
CONFigure:SIGNaling:TOPology:PLMN:MNC <PLMN_Name>, <MNC>Set PLMN MNC. Configures the mobile network code (MNC) of the selected PLMN.
CONFigure:SIGNaling:TOPology:PLMN:MNC? <PLMN_Name>Query PLMN MNC. Queries the mobile network code (MNC) of the selected PLMN.

FETCh (31 only on the CMX500)

CommandWhat it does
FETCh:SIGNaling:TOPology:CNETwork:STATe?Query Core Network State. Queries the state of the core network including the edit mode and live mode states.
FETCh:SIGNaling:TOPology:EPS:UE:STATe? <UE_ID>Query EPS UE State. Queries the registration state of the UE in the EPS tracking areas.
FETCh:SIGNaling:TOPology:FGS:UE:STATe? <UE_ID>Query 5GS UE State. Queries the registration state of the UE in the 5GS tracking areas.
FETCh:SIGNaling:NRADio:CELL:POWer:CONTrol:STATe? <Cell_Name>Query NR Power Control State. Queries whether a TPC power control procedure is running (RUN) or complete (RDY) for the initial bandwidth part.

SOURce (11 only on the CMX500)

CommandWhat it does
SOURce:SIGNaling:NRADio:CELL:STATe <Cell_Name>, ONTurn On NR Cell. Turns the signal of the selected NR cell on.
SOURce:SIGNaling:NRADio:CELL:STATe? <Cell_Name>Query NR Cell State. Queries whether the signal of the selected NR cell is on or off.
SOURce:SIGNaling:LTE:CELL:STATe <Cell_Name>, ONTurn On LTE Cell. Turns the signal of the selected LTE cell on.
SOURce:SIGNaling:LTE:CELL:STATe? <Cell_Name>Query LTE Cell State. Queries whether the signal of the selected LTE cell is on or off.

SYSTem (11 only on the CMX500)

CommandWhat it does
SYSTem:BASE:DEVice:SETup?Query Device Setup. Queries the assignment of hardware resources to the sub-instruments of the test set.
SYSTem:BASE:DEVice:RESetReset Device. Resets the addressed device (channel) of the test set to its initial state.
SYSTem:BASE:DEVice:COUNt <Count>Set Device Count. Splits the instrument into the given number of channels (sub-instruments); a reboot is performed automatically.
SYSTem:BASE:DEVice:COUNt?Query Device Count. Queries the number of channels (sub-instruments) the instrument is split into.

CATalog (9 only on the CMX500)

CommandWhat it does
CATalog:SIGNaling:TOPology:PLMN?Query PLMN Catalog. Queries a list of all created PLMNs.
CATalog:SIGNaling:TOPology:EPS? <PLMN_Name>Query EPS Tracking Areas. Queries a list of all EPS tracking areas; the query can be restricted to a selected PLMN.
CATalog:SIGNaling:TOPology:FGS? <PLMN_Name>Query 5GS Tracking Areas. Queries a list of all 5GS tracking areas; the query can be restricted to a selected PLMN.
CATalog:SIGNaling:NRADio:CELL?Query NR Cell Catalog. Queries a list of all NR cells.

CREate (8 only on the CMX500)

CommandWhat it does
CREate:SIGNaling:TOPology:PLMN <PLMN_Name>, <MCC>, <MNC>Create PLMN. Creates a PLMN with the given unique name and optionally defines its mobile country code and mobile network code.
CREate:SIGNaling:TOPology:EPS <TA_Name>, <PLMN_Name>, <TAC>Create EPS Tracking Area. Creates an EPS (LTE) tracking area in the selected PLMN and optionally defines its tracking area code.
CREate:SIGNaling:TOPology:FGS <TA_Name>, <PLMN_Name>, <TAC>Create 5GS Tracking Area. Creates a 5GS (5G NR) tracking area in the selected PLMN and optionally defines its tracking area code.
CREate:SIGNaling:TOPology:CNETworkCreate Core Network. Creates the core network and switches from edit mode to live mode; this action can take several minutes.

Control both from Python

With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, the two libraries have no common command with a worked example on both, so each instrument uses its own: BSE:CONFig:NR5G:PHY:OPTimize:CONTiguous:STATe 1 on the E7515B and CONFigure:SIGNaling:TMODe ON on the CMX500. For the reading, both libraries hold SYSTem:ERRor? (read error), and the same line runs on each. For the basics, see the PyVISA tutorial.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find both VISA addresses

a = rm.open_resource("PASTE_E7515B_ADDRESS")  # Keysight E7515B
b = rm.open_resource("PASTE_CMX500_ADDRESS")  # Rohde & Schwarz CMX500
for inst in (a, b):
    inst.timeout = 5000  # ms
    print(inst.query("*IDN?"))

# No shared setting with an example on both, so each uses its own command
a.write("BSE:CONFig:NR5G:PHY:OPTimize:CONTiguous:STATe 1")  # Turn On NR Contiguous Optimization
b.write("CONFigure:SIGNaling:TMODe ON")  # Turn On UE Test Mode

# The same reading on both: Read Error
print(a.query("SYSTem:ERRor?"))
print(b.query("SYSTem:ERRor?"))

a.close()
b.close()

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Keysight E7515B or Rohde & Schwarz CMX500 and writes the report from the measured results.

Get started

Frequently asked questions

What is the difference between the Keysight E7515B and the Rohde & Schwarz CMX500 for remote control?

In TestFlow's library the E7515B has 109 SCPI commands and the CMX500 has 266 SCPI commands. 3 command headers are common to both, 92 are only on the E7515B (mostly BSE and SYSTem), and 238 are only on the CMX500 (mostly CONFigure and FETCh).

Can I use the same SCPI code for the Keysight E7515B and the Rohde & Schwarz CMX500?

Partly. 3 command headers are accepted by both, including SYSTem:ERRor?. 330 are not, for example BSE:SELected:CELL on the E7515B and CONFigure:SIGNaling:TOPology:PLMN:MCC on the CMX500, so a script that uses those needs a separate branch for each instrument.

Which has more remote commands, the E7515B or the CMX500?

The CMX500: 109 commands for the E7515B against 266 for the CMX500 in TestFlow's library. Of those, 15 on the E7515B and 104 on the CMX500 are queries that read a value or state, and the library splits them into 7 and 21 subsystems.

How do the E7515B and CMX500 signal operation complete and report errors?

Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?. Each command named here is listed in the tables on this page and on each instrument's command reference.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.