Dynamic Load · SCPI command comparison

Chroma 63102A vs Siglent SDL1020X-E: SCPI commands and remote control compared

In TestFlow's instrument library, the Chroma 63102A takes 31 SCPI commands, 2 of them queries, and the Siglent SDL1020X-E takes 99 SCPI commands, 42 of them queries. That is 68 more on the SDL1020X-E. Counting distinct command headers (the command path without its arguments), 0 are accepted by both, 25 exist only on the 63102A, and 99 only on the SDL1020X-E. None of the 63102A's command headers appears in the SDL1020X-E library, so a script written for one needs every command rewritten for the other.

Both libraries have commands under MEAS. Only the 63102A has CURR, VOLT, RES, CONFigure, LOAD, and MODE and 1 more. Only the SDL1020X-E has SOURce, TRIGger, SENSe, and SYSTem.

Only the SDL1020X-E library has an operation-complete command (*OPC?); the 63102A library has none. Neither library has an error-queue read such as SYSTem:ERRor?.

TestFlow's library gives the 63103A, 63105A, 63106A, 63107A, 63108A, 63110A, 63112A, 63113A, 63123A, and 6314A the same command set as the 63102A, so the 63102A column applies to them too. TestFlow's library gives the SDL1030X-E the same command set as the SDL1020X-E, so the SDL1020X-E column applies to it too.

63102A commands
31
SDL1020X-E commands
99
Shared headers
0
Unique headers
124

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Chroma 63102A or Siglent SDL1020X-E and writes the report from the measured results.

Get started

63102A vs SDL1020X-E at a glance

Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.

Chroma 63102ASiglent SDL1020X-E
Commands in TestFlow's library3199
Queries (read a value or state)242
Settings and actions2957
Subsystems116
Distinct command headers2599
Headers the other lacks2599
Command languageSCPISCPI
Operation completeNot in library*OPC?
Error queueNot in libraryNot in library
Models on this command set63102A, 63103A, 63105A, 63106A, 63107A, 63108A, 63110A, 63112A, 63113A, 63123A, 6314ASDL1020X-E, SDL1030X-E

Commands both accept

None. No command header in TestFlow's 63102A library matches one in its SDL1020X-E library, so every command needs its own version for each instrument.

Only on the Chroma 63102A

25 command headers in the 63102A library have no match in the SDL1020X-E library. Below are 17 of them from the 6 largest subsystems; the full list is in the Chroma 63102A command reference.

CURR (10 only on the 63102A)

CommandWhat it does
CURR:STAT:L1 <Amp>Static Current low. Sets the static current lower value
CURR:STAT:L2 <Amp>Static Current High. Sets the static current higher value (Always set low and high)
CURR:STAT:RISE <Slew>Current rise slew. Sets the current rising slew rate
CURR:STAT:FALL <Slew>Current fall slew. Sets the current falling slew rate

RES (4 only on the 63102A)

CommandWhat it does
RES:L1 <OHM> OHMResistance low. Sets the lower value of dynamic resistive load
RES:L2 <OHM> OHMResistance high. Sets the higher value of dynamic resistive load (Set low and high for constant)
RES:RISE <Slew>Resistance rise. Sets resistive load rise
RES:FALL <Slew>Resistance fall. Sets resistive load fall

VOLT (4 only on the 63102A)

CommandWhat it does
VOLT:L1 <Volt>VStatic voltage low. Sets the lower value of CV mode
VOLT:L2 <Volt>VStatic voltave high. Sets the higher value of the CV mode
VOLTage:CURRent <Amp>Static voltage current limit. Sets the current limit
VOLT:MODE FASTVoltage fast. Sets voltage fast mode

CONFigure (2 only on the 63102A)

CommandWhat it does
:CONFigure:REMote ONRemote control. Sets control to remote
CONF:VOLT:LATC ONVoltage latch ON. Enables voltage latch

MEAS (2 only on the 63102A)

CommandWhat it does
MEAS:VOLT?Measure voltage. Measures the voltage
MEAS:CURR?Measure current. Measures the current

CHANnel (1 only on the 63102A)

CommandWhat it does
CHANnel <Channel>Channel select. Selects the channel

Only on the Siglent SDL1020X-E

99 command headers in the SDL1020X-E library have no match in the 63102A library. Below are 17 of them from the 6 largest subsystems; the full list is in the Siglent SDL1020X-E command reference.

SOURce (74 only on the SDL1020X-E)

CommandWhat it does
:SOURce:INPut:STATe <state>Set Input State. Turns the load input on or off.
:SOURce:INPut:STATe?Query Input State. Returns 1 if the load input is on, otherwise 0.
:SOURce:SHORt:STATe <state>Set Short Circuit State. Sets the short circuit status of the load.
:SOURce:SHORt:STATe?Query Short Circuit State. Returns 1 if the short circuit is on, otherwise 0.

IEEE 488.2 common (*) (14 only on the SDL1020X-E)

CommandWhat it does
*IDN?Identify. Returns the manufacturer, model, serial number and software version string.
*RSTReset. Restores the instrument to its initial state.
*CLSClear Status. Clears the event registers and the error list.
*ESE <number>Set Standard Event Enable. Sets the bits in the standard event status enable register.

MEASure (6 only on the SDL1020X-E)

CommandWhat it does
MEASure:VOLTage:DC?Measure Voltage. Returns the real-time voltage measurement.
MEASure:CURRent:DC?Measure Current. Returns the real-time current measurement.
MEASure:POWer:DC?Measure Power. Returns the real-time power measurement.
MEASure:RESistance:DC?Measure Resistance. Returns the real-time resistance measurement.

SENSe (2 only on the SDL1020X-E)

CommandWhat it does
SENSe:AVERage:COUNt <index>Set Average Count. Sets the averaging point count for read-back current and voltage.
SENSe:AVERage:COUNt?Query Average Count. Returns the averaging point count index.

TRIGger (2 only on the SDL1020X-E)

CommandWhat it does
TRIGger:SOURce <source>Set Trigger Source. Sets the trigger source of the load.
TRIGger:SOURce?Query Trigger Source. Returns the trigger source.

SYSTem (1 only on the SDL1020X-E)

CommandWhat it does
SYSTem:SENSe:STATe <state>Set Sense State. Enables or disables the Sense function.

Control both from Python

With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, the two libraries have no common command with a worked example on both, so each instrument uses its own: :CONFigure:REMote ON on the 63102A and :SOURce:LIST:STATe:ON on the SDL1020X-E. For the reading, the two libraries have no common command with a worked example on both, so each instrument uses its own: MEAS:VOLT? on the 63102A and MEASure:VOLTage:DC? on the SDL1020X-E. For the basics, see the PyVISA tutorial.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find both VISA addresses

a = rm.open_resource("PASTE_63102A_ADDRESS")  # Chroma 63102A
b = rm.open_resource("PASTE_SDL1020X_E_ADDRESS")  # Siglent SDL1020X-E
for inst in (a, b):
    inst.timeout = 5000  # ms
    print(inst.query("*IDN?"))

# No shared setting with an example on both, so each uses its own command
a.write(":CONFigure:REMote ON")  # Remote control
b.write(":SOURce:LIST:STATe:ON")  # Enter List Test

# No shared reading with an example on both, so each uses its own command
print(a.query("MEAS:VOLT?"))  # Measure voltage
print(b.query("MEASure:VOLTage:DC?"))  # Measure Voltage

a.close()
b.close()

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Chroma 63102A or Siglent SDL1020X-E and writes the report from the measured results.

Get started

Frequently asked questions

What is the difference between the Chroma 63102A and the Siglent SDL1020X-E for remote control?

In TestFlow's library the 63102A has 31 SCPI commands and the SDL1020X-E has 99 SCPI commands. 0 command headers are common to both, 25 are only on the 63102A (mostly CURR and RES), and 99 are only on the SDL1020X-E (mostly SOURce and IEEE 488.2 common (*)).

Can I use the same SCPI code for the Chroma 63102A and the Siglent SDL1020X-E?

Not without changes. None of the 25 command headers in the 63102A library matches one of the 99 in the SDL1020X-E library: the 63102A uses commands such as CURR:STAT:L1 and the SDL1020X-E uses commands such as :SOURce:INPut:STATe. PyVISA opens both the same way, but each command needs its own version for each instrument.

Which has more remote commands, the 63102A or the SDL1020X-E?

The SDL1020X-E: 31 commands for the 63102A against 99 for the SDL1020X-E in TestFlow's library. Of those, 2 on the 63102A and 42 on the SDL1020X-E are queries that read a value or state, and the library splits them into 11 and 6 subsystems.

How do the 63102A and SDL1020X-E signal operation complete and report errors?

Only the SDL1020X-E library has an operation-complete command (*OPC?); the 63102A library has none. Neither library has an error-queue read such as SYSTem:ERRor?. Each command named here is listed in the tables on this page and on each instrument's command reference.

Your next test, automated today