Function Generator · SCPI command reference

Berkeley Nucleonics Model 675 SCPI commands

The Berkeley Nucleonics Model 675 function generator is controlled remotely with SCPI commands. TestFlow's instrument library holds 50 commands for it, 8 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the Model 675 on a real bench.

Commands
50
Queries
8
Subsystems
8
Models covered
1

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Berkeley Nucleonics Model 675 and writes the report from the measured results.

Get started

Control the Berkeley Nucleonics Model 675 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Berkeley Nucleonics Model 675's VISA address

# Paste the address of your Berkeley Nucleonics Model 675 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("OUTPut1:STATe ON")  # Turn On Output
print(inst.query("SYSTem:ERRor?"))  # Read Error

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Berkeley Nucleonics Model 675 and writes the report from the measured results.

Get started

Run a Model 675 test without writing code

Describe the test in a sentence, for example “turn on output on the Model 675, then read error and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

50 commands in 8 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Source (SOURce) (31)

CommandWhat it doesArguments
SOURce<Channel>:FUNCtion <Shape>Set Function. Sets the output waveform shape for the selected channel.Number: 1,2; Text: SINusoid,SQUare,RAMP,PULSe,NOISe,ARB,DC
SOURce<Channel>:FUNCtion?Read Function. Reads the output waveform shape for the selected channel.Number: 1,2
SOURce<Channel>:FREQuency <Freq>Set Frequency. Sets the output frequency in Hz for the selected channel.Number: 1,2; Number
SOURce<Channel>:FREQuency?Read Frequency. Reads the output frequency for the selected channel.Number: 1,2
SOURce<Channel>:VOLTage <Amp>Set Amplitude. Sets the output amplitude (Vpp) for the selected channel.Number: 1,2; Number
SOURce<Channel>:VOLTage?Read Amplitude. Reads the output amplitude for the selected channel.Number: 1,2
SOURce<Channel>:VOLTage:OFFSet <Volt>Set Voltage Offset. Sets the DC offset voltage for the selected channel.Number: 1,2; Number
SOURce<Channel>:VOLTage:HIGH <Volt>Set Voltage High. Sets the high voltage level for the selected channel.Number: 1,2; Number
SOURce<Channel>:VOLTage:LOW <Volt>Set Voltage Low. Sets the low voltage level for the selected channel.Number: 1,2; Number
SOURce<Channel>:PHASe <Deg>Set Phase. Sets the output phase in degrees for the selected channel.Number: 1,2; Number
SOURce<Channel>:FUNCtion:RAMP:SYMMetry <Pct>Set Ramp Symmetry. Sets the ramp symmetry percentage for the selected channel.Number: 1,2; Number
SOURce<Channel>:FUNCtion:SQUare:DCYCle <Pct>Set Square Duty Cycle. Sets the square-wave duty cycle for the selected channel.Number: 1,2; Number
SOURce<Channel>:PULSe:WIDTh <Sec>Set Pulse Width. Sets the pulse width in seconds for the selected channel.Number: 1,2; Number
SOURce<Channel>:PULSe:PERiod <Sec>Set Pulse Period. Sets the pulse period in seconds for the selected channel.Number: 1,2; Number
SOURce<Channel>:FUNCtion:ARBitrary <Name>Set Arb Waveform. Selects the arbitrary waveform for the selected channel.Number: 1,2; Text
SOURce<Channel>:FUNCtion:ARBitrary:SRATe <Rate>Set Arb Sample Rate. Sets the arbitrary sample rate for the selected channel.Number: 1,2; Number
SOURce<Channel>:AM:STATe ONEnable AM. Enables AM modulation on the selected channel.Number: 1,2
SOURce<Channel>:AM:STATe OFFDisable AM. Disables AM modulation on the selected channel.Number: 1,2
SOURce<Channel>:AM:DEPTh <Pct>Set AM Depth. Sets the AM depth percentage for the selected channel.Number: 1,2; Number
SOURce<Channel>:FM:STATe ONEnable FM. Enables FM modulation on the selected channel.Number: 1,2
SOURce<Channel>:FM:STATe OFFDisable FM. Disables FM modulation on the selected channel.Number: 1,2
SOURce<Channel>:FM:DEViation <Freq>Set FM Deviation. Sets the FM frequency deviation for the selected channel.Number: 1,2; Number
SOURce<Channel>:SWEep:STATe ONEnable Sweep. Enables the frequency sweep on the selected channel.Number: 1,2
SOURce<Channel>:SWEep:STATe OFFDisable Sweep. Disables the frequency sweep on the selected channel.Number: 1,2
SOURce<Channel>:FREQuency:STARt <Freq>Set Sweep Start Freq. Sets the sweep start frequency for the selected channel.Number: 1,2; Number
SOURce<Channel>:FREQuency:STOP <Freq>Set Sweep Stop Freq. Sets the sweep stop frequency for the selected channel.Number: 1,2; Number
SOURce<Channel>:SWEep:TIME <Sec>Set Sweep Time. Sets the sweep time for the selected channel.Number: 1,2; Number
SOURce<Channel>:BURSt:STATe ONEnable Burst. Enables burst mode on the selected channel.Number: 1,2
SOURce<Channel>:BURSt:STATe OFFDisable Burst. Disables burst mode on the selected channel.Number: 1,2
SOURce<Channel>:BURSt:NCYCles <N>Set Burst Cycles. Sets the number of cycles per burst for the selected channel.Number: 1,2; Number
SOURce<Channel>:BURSt:INTernal:PERiod <Sec>Set Burst Period. Sets the internal burst period for the selected channel.Number: 1,2; Number

Output (OUTPut) (4)

CommandWhat it doesArguments
OUTPut<Channel>:STATe ONTurn On Output. Enables the selected channel output.Number: 1,2
OUTPut<Channel>:STATe OFFTurn Off Output. Disables the selected channel output.Number: 1,2
OUTPut<Channel>:STATe?Read Output State. Reads the selected channel output state.Number: 1,2
OUTPut<Channel>:LOAD <Ohm>Set Output Load. Sets the selected channel output load in ohms; use INF for high-Z.Number: 1,2; Number

Trigger (TRIGger) (2)

CommandWhat it doesArguments
TRIGger:SOURce <Src>Set Trigger Source. Sets the trigger source.Text: IMMediate,EXTernal,BUS
TRIGgerTrigger Now. Issues an immediate trigger.None

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads and clears the next error-queue entry.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (9)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete.None
*TRGTrigger Bus. Generates a bus trigger.None
*SAV <Slot>Save State Slot. Stores the current state to a memory slot.Number
*RCL <Slot>Recall State Slot. Recalls a state from a memory slot.Number

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Berkeley Nucleonics's programming documentation for the Model 675 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Berkeley Nucleonics's programming manual: check it before you rely on an edge case. Last updated July 8, 2026.

Frequently asked questions

Does the Berkeley Nucleonics Model 675 support SCPI remote control?

Yes. The Berkeley Nucleonics Model 675 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 50 SCPI commands for it: 8 queries that read values or state, and 42 settings and actions.

How do I control the Berkeley Nucleonics Model 675 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut1:STATe ON and SYSTem:ERRor?.

Which command reads a value from the Berkeley Nucleonics Model 675?

SYSTem:ERRor? (read error). Reads and clears the next error-queue entry. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Berkeley Nucleonics Model 675 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Berkeley Nucleonics Model 675 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.