Multimeter · SCPI command reference

Aim-TTi 1604 SCPI commands

The Aim-TTi 1604 multimeter is controlled remotely with SCPI commands. TestFlow's instrument library holds 59 commands for it, 18 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the 1604 on a real bench.

Commands
59
Queries
18
Subsystems
15
Models covered
1

Control the Aim-TTi 1604 from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Aim-TTi 1604's VISA address

# Paste the address of your Aim-TTi 1604 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("CONFigure:VOLTage:DC")  # Conf DCV
print(inst.query("MEASure:VOLTage:DC?"))  # Measure DCV

inst.close()

Run a 1604 test without writing code

Describe the test in a sentence, for example “conf dcv on the 1604, then measure dcv and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

59 commands in 15 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.

Configure (CONFigure) (12)

CommandWhat it doesArguments
CONFigure:VOLTage:DCConf DCV. Configures the meter to measure DC voltage.None
CONFigure:VOLTage:ACConf ACV. Configures the meter to measure AC voltage.None
CONFigure:CURRent:DCConf DCI. Configures the meter to measure DC current.None
CONFigure:CURRent:ACConf ACI. Configures the meter to measure AC current.None
CONFigure:RESistanceConf 2W Resistance. Configures the meter to measure 2-wire resistance.None
CONFigure:FRESistanceConf 4W Resistance. Configures the meter to measure 4-wire resistance.None
CONFigure:FREQuencyConf Frequency. Configures the meter to measure frequency.None
CONFigure:PERiodConf Period. Configures the meter to measure period.None
CONFigure:CAPacitanceConf Capacitance. Configures the meter to measure capacitance.None
CONFigure:TEMPeratureConf Temperature. Configures the meter to measure temperature.None
CONFigure:CONTinuityConf Continuity. Configures the meter for continuity testing.None
CONFigure:DIODeConf Diode. Configures the meter for diode testing.None

Calculate (CALCulate) (12)

CommandWhat it doesArguments
CALCulate:NULL:STATe ONRel On. Enables the relative (null) operation.None
CALCulate:NULL:STATe OFFRel Off. Disables the relative (null) operation.None
CALCulate:NULL:OFFSet <Offset>Set Rel Offset. Sets the reference value used by the relative (null) operation.Number
CALCulate:DB:STATe ONDB On. Enables the dB math operation.None
CALCulate:DB:STATe OFFDB Off. Disables the dB math operation.None
CALCulate:DBM:STATe ONDBm On. Enables the dBm math operation.None
CALCulate:DBM:STATe OFFDBm Off. Disables the dBm math operation.None
CALCulate:AVERage:STATe ONStatistics On. Enables the min/max/average statistics operation.None
CALCulate:AVERage:STATe OFFStatistics Off. Disables the min/max/average statistics operation.None
CALCulate:AVERage:MINimum?Read Min. Returns the minimum of the collected statistics.None
CALCulate:AVERage:MAXimum?Read Max. Returns the maximum of the collected statistics.None
CALCulate:AVERage:AVERage?Read Average. Returns the average of the collected statistics.None

Sense (SENSe) (9)

CommandWhat it doesArguments
SENSe:VOLTage:DC:RANGe <Range>Set DCV Range. Sets the DC voltage measurement range in volts.Number
SENSe:VOLTage:AC:RANGe <Range>Set ACV Range. Sets the AC voltage measurement range in volts.Number
SENSe:CURRent:DC:RANGe <Range>Set DCI Range. Sets the DC current measurement range in amps.Number
SENSe:RESistance:RANGe <Range>Set Resistance Range. Sets the 2-wire resistance measurement range in ohms.Number
SENSe:VOLTage:DC:RANGe:AUTO ONDCV Autorange On. Enables autorange for DC voltage.None
SENSe:VOLTage:DC:RANGe:AUTO OFFDCV Autorange Off. Disables autorange for DC voltage.None
SENSe:RESistance:RANGe:AUTO ONResistance Autorange On. Enables autorange for resistance.None
SENSe:RESistance:RANGe:AUTO OFFResistance Autorange Off. Disables autorange for resistance.None
SENSe:VOLTage:DC:NPLCycles <NPLC>Set DCV NPLC. Sets the DC voltage integration time in power line cycles.Number: 0.02,0.2,1,10,100

Measurement (MEASure) (8)

CommandWhat it doesArguments
MEASure:VOLTage:DC?Measure DCV. Configures DC voltage and returns one measured value in volts.None
MEASure:VOLTage:AC?Measure ACV. Configures AC voltage and returns one measured value in volts.None
MEASure:CURRent:DC?Measure DCI. Configures DC current and returns one measured value in amps.None
MEASure:CURRent:AC?Measure ACI. Configures AC current and returns one measured value in amps.None
MEASure:RESistance?Measure 2W Resistance. Configures 2-wire resistance and returns one measured value in ohms.None
MEASure:FRESistance?Measure 4W Resistance. Configures 4-wire resistance and returns one measured value in ohms.None
MEASure:FREQuency?Measure Frequency. Configures frequency and returns one measured value in Hz.None
MEASure:CAPacitance?Measure Capacitance. Configures capacitance and returns one measured value in farads.None

Trigger (TRIGger) (2)

CommandWhat it doesArguments
TRIGger:SOURce <Source>Set Trigger Source. Sets the trigger source.Text: IMMediate,EXTernal,BUS
TRIGger:COUNt <Count>Set Trigger Count. Sets the number of triggers accepted before returning to idle.Number

Function (FUNCtion) (1)

CommandWhat it doesArguments
FUNCtion?Read Function. Queries the present measurement function.None

Read (READ) (1)

CommandWhat it doesArguments
READ?Read Value. Triggers and returns one new measurement of the active function.None

Fetch (FETCh) (1)

CommandWhat it doesArguments
FETCh?Fetch Value. Returns the last measurement without re-triggering.None

SAMP subsystem (1)

CommandWhat it doesArguments
SAMPle:COUNt <Count>Set Sample Count. Sets the number of samples taken per trigger.Number

Initiate (INITiate) (1)

CommandWhat it doesArguments
INITiateInit Trigger. Places the meter in the wait-for-trigger state.None

System (SYSTem) (1)

CommandWhat it doesArguments
SYSTem:ERRor?Read Error. Reads the first message from the error queue.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (7)

CommandWhat it doesArguments
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass or 1 for failure.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None
*TRGTrigger Bus. Generates a bus trigger when the instrument is in wait-for-trigger state.None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Aim-TTi's programming documentation for the 1604 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Aim-TTi's programming manual: check it before you rely on an edge case. Last updated June 18, 2026.

Frequently asked questions

Does the Aim-TTi 1604 support SCPI remote control?

Yes. The Aim-TTi 1604 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 59 SCPI commands for it: 18 queries that read values or state, and 41 settings and actions.

How do I control the Aim-TTi 1604 from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, CONFigure:VOLTage:DC and MEASure:VOLTage:DC?.

Which command reads a value from the Aim-TTi 1604?

MEASure:VOLTage:DC? (measure dcv). Configures DC voltage and returns one measured value in volts. The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Aim-TTi 1604 without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Aim-TTi 1604 through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.