The Tescom MTP120A radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 60 commands for it, 31 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the MTP120A on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Tescom MTP120A and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Tescom MTP120A's VISA address
# Paste the address of your Tescom MTP120A (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("SOURce:GENerator:OUT_A1:STATe ON") # Generator On
print(inst.query("READ:LINK:BT_A:CONNected:BDADdress?")) # Read BT Connected Address
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Tescom MTP120A and writes the report from the measured results.
Describe the test in a sentence, for example “generator on on the MTP120A, then read bt connected address and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
60 commands in 9 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values.
| Command | What it does | Arguments |
|---|---|---|
| CONFigure:MEASurement:<Port>:MODe <Mode> | Set Analyzer Mode. Sets the input port mode: AMP or LINE. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Text: AMP,LINE |
| CONFigure:MEASurement:<Port>:MODe? | Read Analyzer Mode. Returns the input port mode (AMP or LINE). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:TONE:ENHANced ON | Enhanced Mode On. Turns enhanced mode on (from 20 Hz, FFT size 32768). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:TONE:ENHANced OFF | Enhanced Mode Off. Turns enhanced mode off (from 100 Hz, FFT size 8196). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:TONE:ENHANced? | Read Enhanced Mode. Returns the enhanced mode state (ON or OFF). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:TARGet <Target> | Set Sweep Target. Sets the generator port (target SG) used as the source for sweep measurements on the input port. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2 |
| CONFigure:MEASurement:<Port>:TARGet? | Read Sweep Target. Returns the generator port used as the sweep source. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:STEP:STARt <Freq> | Set Step Start Frequency. Sets the step sweep start frequency in Hz (20 to 20000). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Number: 20,20000 |
| CONFigure:MEASurement:<Port>:STEP:STARt? | Read Step Start Frequency. Returns the step sweep start frequency in Hz. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:STEP:END <Freq> | Set Step End Frequency. Sets the step sweep end frequency in Hz (20 to 20000). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Number: 20,20000 |
| CONFigure:MEASurement:<Port>:STEP:END? | Read Step End Frequency. Returns the step sweep end frequency in Hz. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:STEP:NUMPoint <Points> | Set Step Points. Sets the number of step sweep points (10 to 10000). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Number: 10,10000 |
| CONFigure:MEASurement:<Port>:STEP:NUMPoint? | Read Step Points. Returns the number of step sweep points. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:STEP:SCALe <Scale> | Set Step Scale. Sets the step sweep frequency scale. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Text: LOG,LINEAR |
| CONFigure:MEASurement:<Port>:STEP:SCALe? | Read Step Scale. Returns the step sweep frequency scale. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:STEP:NUMRetry <Retries> | Set Step Retries. Sets the number of retries per step (3 to 10). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Number: 3,10 |
| CONFigure:MEASurement:<Port>:STEP:NUMRetry? | Read Step Retries. Returns the number of retries per step. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:SWEEP:STARt <Freq> | Set Sweep Start Frequency. Sets the hybrid sweep start frequency in Hz (20 or 100). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Number: 20,100 |
| CONFigure:MEASurement:<Port>:SWEEP:STARt? | Read Sweep Start Frequency. Returns the hybrid sweep start frequency in Hz. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:SWEEP:END <Freq> | Set Sweep End Frequency. Sets the hybrid sweep end frequency in Hz (4000, 8000, 10000 or 20000). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Number: 4000,8000,10000,20000 |
| CONFigure:MEASurement:<Port>:SWEEP:END? | Read Sweep End Frequency. Returns the hybrid sweep end frequency in Hz. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:SWEEP:OCTave <Octave> | Set Sweep Octave. Sets the octave band resolution of the hybrid sweep (3, 6 or 12). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Number: 3,6,12 |
| CONFigure:MEASurement:<Port>:SWEEP:OCTave? | Read Sweep Octave. Returns the octave band resolution of the hybrid sweep. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:SWEEP:ACTtime <Seconds> | Set Sweep Active Time. Sets the hybrid sweep active time in seconds (0 to 10). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Number: 0,10 |
| CONFigure:MEASurement:<Port>:SWEEP:ACTtime? | Read Sweep Active Time. Returns the hybrid sweep active time in seconds. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| CONFigure:MEASurement:<Port>:SWEEP:INACTtime <Seconds> | Set Sweep Inactive Time. Sets the hybrid sweep inactive time in seconds (0 to 10). | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1; Number: 0,10 |
| CONFigure:MEASurement:<Port>:SWEEP:INACTtime? | Read Sweep Inactive Time. Returns the hybrid sweep inactive time in seconds. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| Command | What it does | Arguments |
|---|---|---|
| READ:LINK:<Port>:CONNected:BDADdress? | Read BT Connected Address. Returns the BD address of the connected Bluetooth device. | Text: BT_A,BT_B |
| READ:LINK:<Port>:CONNected:NAMe? | Read BT Connected Name. Returns the name of the connected Bluetooth device. | Text: BT_A,BT_B |
| READ:LINK:<Port>:CONNected:LINk? | Read BT Link State. Returns 1 if a Bluetooth device is connected or 0 if not. | Text: BT_A,BT_B |
| READ:MEASurement:<Port>:DISTortion:SNR? | Read Distortion SNR. Returns the measured SNR. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| READ:MEASurement:<Port>:DISTortion:THD? | Read Distortion THD. Returns the measured THD. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| READ:MEASurement:<Port>:DISTortion:SINAD? | Read Distortion SINAD. Returns the measured SINAD. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| READ:MEASurement:<Port>:DISTortion:LEVEL? | Read Distortion Level. Returns the measured level. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| READ:MEASurement:<Port>:DISTortion:FREQ? | Read Distortion Frequency. Returns the measured frequency. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| READ:MEASurement:<Port>:DISTortion:GRAPh? | Read Distortion Graph. Returns the spectrum graph as a frequency list and a level list. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| READ:MEASurement:<Port>:STEP? | Read Step Sweep. Returns [FREQ, LEVEL, SNR, THD, SINAD] for each step frequency. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| READ:MEASurement:<Port>:SWEEP? | Read Hybrid Sweep. Returns the hybrid sweep result as a frequency list and a value list. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| Command | What it does | Arguments |
|---|---|---|
| SOURce:GENerator:<Port>:STATe ON | Generator On. Turns on single-tone generation on the selected output port. | Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2 |
| SOURce:GENerator:<Port>:STATe OFF | Generator Off. Turns off single-tone generation on the selected output port. | Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2 |
| SOURce:GENerator:<Port>:STATe? | Read Generator State. Returns ON or OFF for the selected output port. | Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2 |
| SOURce:GENerator:<Port>:MODe <Mode> | Set Generator Mode. Sets the output port mode: AMP (amplifier) or LINE. | Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2; Text: AMP,LINE |
| SOURce:GENerator:<Port>:MODe? | Read Generator Mode. Returns the output port mode (AMP or LINE). | Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2 |
| SOURce:GENerator:<Port>:TONE:FREQuency <Freq> | Set Tone Frequency. Sets the single-tone frequency in Hz (20 to 20000). | Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2; Number: 20,20000 |
| SOURce:GENerator:<Port>:TONE:FREQuency? | Read Tone Frequency. Returns the single-tone frequency in Hz. | Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2 |
| SOURce:GENerator:<Port>:TONE:LEVel <Level> | Set Tone Level. Sets the single-tone level in dBV (AMP: -60 to 10, LINE: -80 to 0). | Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2; Number: -80,10 |
| SOURce:GENerator:<Port>:TONE:LEVel? | Read Tone Level. Returns the single-tone level in dBV. | Text: OUT_A1,OUT_A2,OUT_B1,OUT_B2,BT_OUT_A1,BT_OUT_A2,BT_OUT_B1,BT_OUT_B2 |
| Command | What it does | Arguments |
|---|---|---|
| EXECute:LINK:<Port>:DISCOVer | BT Discover Connect. Searches for a Bluetooth device on the selected BT RF port and connects to the device found. | Text: BT_A,BT_B |
| EXECute:LINK:<Port>:DISConnect | BT Disconnect. Disconnects the Bluetooth device connected on the selected BT RF port. | Text: BT_A,BT_B |
| EXECute:MEASurement:<Port>:DISTortion | Measure Distortion. Starts the single-tone distortion measurement on the input port. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| EXECute:MEASurement:<Port>:STEP | Measure Step Sweep. Starts the step sweep measurement. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| EXECute:MEASurement:<Port>:SWEEP | Measure Hybrid Sweep. Starts the hybrid sweep measurement. | Text: IN_A1,IN_A2,IN_B1,IN_B2,BT_IN_A1,BT_IN_B1 |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:ERRor? | Read Error. Returns the error code, error string and offending command (0 = No error). | None |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial number, firmware). | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *OPC? | Operation Complete. Returns 1 when the previous command has completed and 0 otherwise. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete before continuing. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Tescom's programming documentation for the MTP120A and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Tescom's programming manual: check it before you rely on an edge case. Last updated September 27, 2026.
Yes. The Tescom MTP120A accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 60 SCPI commands for it: 31 queries that read values or state, and 29 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SOURce:GENerator:OUT_A1:STATe ON and READ:LINK:BT_A:CONNected:BDADdress?.
READ:LINK:BT_A:CONNected:BDADdress? (read bt connected address). Returns the BD address of the connected Bluetooth device. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Tescom MTP120A through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.