The Copper Mountain R140, R180, and R60 vector network analyzer is controlled remotely with SCPI commands. TestFlow's instrument library holds 55 commands for it, 13 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the R140 on a real bench.
Describe the test; TestFlow's agent uses this command set to drive your Copper Mountain R140, R180, or R60 and writes the report from the measured results.
With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find the Copper Mountain R140's VISA address
# Paste the address of your Copper Mountain R140 (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000 # ms
print(inst.query("*IDN?")) # identify the instrument
inst.write("OUTPut:STATe ON") # RF Power On
print(inst.query("SENSe:FREQuency:STARt?")) # Read Start Freq
inst.close()Describe the test; TestFlow's agent uses this command set to drive your Copper Mountain R140, R180, or R60 and writes the report from the measured results.
Describe the test in a sentence, for example “rf power on on the R140, then read start freq and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.
55 commands in 13 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The R140, R180, and R60 share this command set in TestFlow's library.
| Command | What it does | Arguments |
|---|---|---|
| SENSe:FREQuency:STARt <Frequency> | Set Start Freq. Sets the sweep start frequency in Hz. | Number |
| SENSe:FREQuency:STOP <Frequency> | Set Stop Freq. Sets the sweep stop frequency in Hz. | Number |
| SENSe:FREQuency:CENTer <Frequency> | Set Center Freq. Sets the sweep center frequency in Hz. | Number |
| SENSe:FREQuency:SPAN <Frequency> | Set Span Freq. Sets the sweep frequency span in Hz. | Number |
| SENSe:FREQuency:STARt? | Read Start Freq. Returns the current start frequency in Hz. | None |
| SENSe:FREQuency:STOP? | Read Stop Freq. Returns the current stop frequency in Hz. | None |
| SENSe:SWEep:POINts <Points> | Set Points. Sets the number of measurement points per sweep. | Number |
| SENSe:SWEep:POINts? | Read Points. Returns the number of measurement points per sweep. | None |
| SENSe:SWEep:TYPE <Type> | Set Sweep Type. Sets the sweep type (linear, log, segment, power, or CW). | Text: LINear,LOGarithmic,SEGMent |
| SENSe:BANDwidth <Bandwidth> | Set IF Bandwidth. Sets the IF (resolution) bandwidth in Hz. | Number |
| SENSe:BANDwidth? | Read IF Bandwidth. Returns the current IF bandwidth in Hz. | None |
| SENSe:AVERage:STATe ON | Average On. Enables trace averaging. | None |
| SENSe:AVERage:STATe OFF | Average Off. Disables trace averaging. | None |
| SENSe:AVERage:COUNt <Count> | Set Average Count. Sets the number of sweeps to average. | Number |
| SENSe:AVERage:CLEar | Average Clear. Restarts (clears) the averaging measurement. | None |
| SENSe:CORRection:STATe ON | Correction On. Turns measurement error correction (calibration) on. | None |
| SENSe:CORRection:STATe OFF | Correction Off. Turns measurement error correction (calibration) off. | None |
| Command | What it does | Arguments |
|---|---|---|
| CALCulate:PARameter<Trace>:DEFine <Parameter> | Define Measurement. Creates a new measurement trace with the given name and S-parameter. | Number: 1,2,3,4; Text: S11 |
| CALCulate:PARameter<Trace>:SELect | Select By Number. Selects the active measurement by its trace number. | Number: 1,2,3,4 |
| CALCulate:FORMat <Format> | Set Format. Sets the display/data format for the selected trace. | Text: MLOGarithmic,MLINear,PHASe,UPHase,SMITh,POLar,SWR,GDELay,REAL,IMAGinary |
| CALCulate:FORMat? | Read Format. Returns the display/data format of the selected trace. | None |
| CALCulate:DATA:FDATa? | Read Formatted Data. Returns the formatted trace data array for the selected measurement. | None |
| CALCulate:DATA:SDATa? | Read Complex Data. Returns the corrected complex (real/imag) trace data array. | None |
| CALCulate:MARKer<Marker>:STATe ON | Marker On. Turns on the specified marker on the active trace. | Number: 1,2,3,4,5,6,7,8,9,10 |
| CALCulate:MARKer<Marker>:STATe OFF | Marker Off. Turns off the specified marker on the active trace. | Number: 1,2,3,4,5,6,7,8,9,10 |
| CALCulate:MARKer<Marker>:X <Frequency> | Set Marker X. Sets the stimulus (X) position of the marker in Hz. | Number: 1,2,3,4,5,6,7,8,9,10; Number |
| CALCulate:MARKer<Marker>:X? | Read Marker X. Returns the stimulus (X) position of the marker. | Number: 1,2,3,4,5,6,7,8,9,10 |
| CALCulate:MARKer<Marker>:Y? | Read Marker Y. Returns the response (Y) value at the marker. | Number: 1,2,3,4,5,6,7,8,9,10 |
| CALCulate:MARKer<Marker>:FUNCtion:TYPE MAXimum ; CALCulate:MARKer<Marker>:FUNCtion:EXECute | Marker Search Max. Moves the marker to the trace maximum. | Number: 1,2,3,4,5,6,7,8,9,10 |
| CALCulate:MARKer<Marker>:FUNCtion:TYPE MINimum ; CALCulate:MARKer<Marker>:FUNCtion:EXECute | Marker Search Min. Moves the marker to the trace minimum. | Number: 1,2,3,4,5,6,7,8,9,10 |
| Command | What it does | Arguments |
|---|---|---|
| INITiate:CONTinuous ON | Continuous On. Enables continuous (free-run) triggering. | None |
| INITiate:CONTinuous OFF | Continuous Off. Disables continuous triggering (hold/single mode). | None |
| INITiate:IMMediate | Trigger Single. Triggers a single sweep when not in continuous mode. | None |
| Command | What it does | Arguments |
|---|---|---|
| DISPlay:WINDow:TRACe:Y:SCALe:AUTO | Autoscale. Autoscales the active trace to fit the display. | None |
| DISPlay:WINDow:TRACe:Y:SCALe:PDIVision <Per_Div> | Set Y Scale. Sets the vertical scale per division for the active trace. | Number |
| DISPlay:WINDow:TRACe:Y:SCALe:RLEVel <Level> | Set Ref Level. Sets the reference level for the active trace. | Number |
| Command | What it does | Arguments |
|---|---|---|
| MMEMory:STORe '<Filename>' | Save State. Saves the instrument state/data to the named file. | Text |
| MMEMory:LOAD '<Filename>' | Recall State. Recalls an instrument state from the named file. | Text |
| MMEMory:STORe:IMAGe '<Filename>' | Save Screenshot. Saves a screenshot image to the named file. | Text |
| Command | What it does | Arguments |
|---|---|---|
| SOURce:POWer <Power> | Set Power Level. Sets the source output power level in dBm. | Number |
| SOURce:POWer? | Read Power Level. Returns the source output power level in dBm. | None |
| Command | What it does | Arguments |
|---|---|---|
| OUTPut:STATe ON | RF Power On. Turns the RF source power output on. | None |
| OUTPut:STATe OFF | RF Power Off. Turns the RF source power output off. | None |
| Command | What it does | Arguments |
|---|---|---|
| SYSTem:PRESet | Preset. Presets the analyzer to its default measurement state. | None |
| SYSTem:ERRor? | Read Error. Reads the next message from the error queue. | None |
| Command | What it does | Arguments |
|---|---|---|
| TRIGger:SOURce <Source> | Set Trigger Source. Sets the trigger source for the sweep. | Text: INTernal,EXTernal,BUS |
| Command | What it does | Arguments |
|---|---|---|
| <Output Variable>=<Equation> | Math. Variable equals an equation like (${Var_name}= ${Var_name}/2) | Number; Text |
| Command | What it does | Arguments |
|---|---|---|
| wait(<ms>) | Wait. Waits for number of milliseconds | Number |
| Command | What it does | Arguments |
|---|---|---|
| save2var <Variable_name> | Save2Variable. Saves last measurement to a variable | Text |
| Command | What it does | Arguments |
|---|---|---|
| *IDN? | Identify. Returns the instrument identification string (manufacturer, model, serial, firmware). | None |
| *RST | Reset. Resets the instrument to its default state. | None |
| *CLS | Clear Status. Clears all event registers and the error queue. | None |
| *OPC? | Operation Complete. Returns 1 when all pending operations are complete. | None |
| *WAI | Wait To Continue. Waits until all pending operations are complete before continuing. | None |
| *TRG | Trigger Bus. Generates a bus trigger when the instrument is in wait-for-trigger state. | None |
This reference is generated from TestFlow's instrument library, which is drafted from Copper Mountain's programming documentation for the R140, R180, and R60 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Copper Mountain's programming manual: check it before you rely on an edge case. Last updated November 17, 2026.
Yes. The Copper Mountain R140 accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 55 SCPI commands for it: 13 queries that read values or state, and 42 settings and actions.
Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, OUTPut:STATe ON and SENSe:FREQuency:STARt?.
SENSe:FREQuency:STARt? (read start freq). Returns the current start frequency in Hz. The full list of queries is in the command reference on this page, grouped by subsystem.
Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Copper Mountain R140 through the TestFlow desktop app, and writes the report from the measured results.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.