Function Generator · SCPI command comparison

Siglent SDG1032X vs Tektronix AFG1022: SCPI commands and remote control compared

In TestFlow's instrument library, the Siglent SDG1032X takes 74 SCPI commands, 9 of them queries, and the Tektronix AFG1022 takes 67 SCPI commands, 10 of them queries. That is 7 more on the SDG1032X. Counting distinct command headers (the command path without its arguments), 8 are accepted by both, 17 exist only on the SDG1032X, and 48 only on the AFG1022. 32% of the SDG1032X's command headers also exist on the AFG1022.

Only the SDG1032X has C, COUP, ROSC, BUZZ, and SCSV. Only the AFG1022 has SOURce, OUTPut, and SYSTem.

Only the SDG1032X library has an operation-complete command (*OPC?); the AFG1022 library has none. Only the AFG1022 library has an error-queue read (SYSTem:ERRor?); the SDG1032X library has none.

TestFlow's library gives the AFG1062 the same command set as the AFG1022, so the AFG1022 column applies to it too.

SDG1032X commands
74
AFG1022 commands
67
Shared headers
8
Unique headers
65

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Siglent SDG1032X or Tektronix AFG1022 and writes the report from the measured results.

Get started

SDG1032X vs AFG1022 at a glance

Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.

Siglent SDG1032XTektronix AFG1022
Commands in TestFlow's library7467
Queries (read a value or state)910
Settings and actions6557
Subsystems97
Distinct command headers2556
Headers the other lacks1748
Command languageSCPISCPI
Operation complete*OPC?Not in library
Error queueNot in librarySYSTem:ERRor?
Models on this command setSDG1032XAFG1022, AFG1062

Commands both accept

8 command headers are in both libraries.

CommandWhat it does
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).
*RSTReset. Resets the instrument to its default state.
*CLSClear Status. Clears all event registers and the error queue.
*WAIWait To Continue. Waits until all pending operations are complete.
*TRGTrigger Bus. Generates a bus trigger.
*SAV <Slot>Save State Slot. Stores the current state to a memory slot.
*RCL <Slot>Recall State Slot. Recalls a state from a memory slot.
*OPT?Read Options. Queries the installed options.

Only on the Siglent SDG1032X

17 command headers in the SDG1032X library have no match in the AFG1022 library. Below are 10 of them from the 6 largest subsystems; the full list is in the Siglent SDG1032X command reference.

C (11 only on the SDG1032X)

CommandWhat it does
C<Channel>:OUTP ONTurn On Output. Enables the selected channel output.
C<Channel>:OUTP?Read Output State. Reads the selected channel output state and settings.
C<Channel>:BSWV WVTP,<Shape>Set Function. Sets the basic waveform type for the selected channel.
C<Channel>:BSWV?Read Basic Waveform. Reads all basic-waveform parameters for the selected channel.

IEEE 488.2 common (*) (2 only on the SDG1032X)

CommandWhat it does
*TST?Self Test. Runs the self-test and returns 0 for pass.
*OPC?Operation Complete. Returns 1 when all pending operations are complete.

BUZZ (1 only on the SDG1032X)

CommandWhat it does
BUZZ ONBuzzer On. Enables the buzzer.

COUP (1 only on the SDG1032X)

CommandWhat it does
COUP TRACE,ONEnable Channel Coupling. Enables channel tracking/coupling.

ROSC (1 only on the SDG1032X)

CommandWhat it does
ROSC INTSet Clock Internal. Uses the internal reference clock.

SCSV (1 only on the SDG1032X)

CommandWhat it does
SCSV <Minutes>Screen Save On. Enables the screen saver.

Only on the Tektronix AFG1022

48 command headers in the AFG1022 library have no match in the SDG1032X library. Below are 9 of them from the 3 largest subsystems; the full list is in the Tektronix AFG1022 command reference.

SOURce (43 only on the AFG1022)

CommandWhat it does
SOURce<Channel>:FUNCtion:SHAPe <Shape>Set Function. Sets the output waveform shape for the selected channel.
SOURce<Channel>:FUNCtion:SHAPe?Read Function. Reads the output waveform shape for the selected channel.
SOURce<Channel>:FREQuency:FIXed <Freq>Set Frequency. Sets the output frequency in Hz for the selected channel.
SOURce<Channel>:FREQuency:FIXed?Read Frequency. Reads the output frequency for the selected channel.

OUTPut (4 only on the AFG1022)

CommandWhat it does
OUTPut<Channel>:STATe ONTurn On Output. Enables the selected channel output.
OUTPut<Channel>:STATe?Read Output State. Reads whether the selected channel output is on.
OUTPut<Channel>:IMPedance <Ohm>Set Output Impedance. Sets the the selected channel output load impedance in ohms (1 to 10k).
OUTPut<Channel>:IMPedance?Read Output Impedance. Reads the the selected channel output load impedance.

SYSTem (1 only on the AFG1022)

CommandWhat it does
SYSTem:ERRor?Read Error. Reads and clears the next error-queue entry.

Control both from Python

With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, the two libraries have no common command with a worked example on both, so each instrument uses its own: C1:OUTP ON on the SDG1032X and OUTPut1:STATe ON on the AFG1022. For the reading, the two libraries have no common command with a worked example on both, so each instrument uses its own: *TST? on the SDG1032X and SYSTem:ERRor? on the AFG1022. For the basics, see the PyVISA tutorial.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find both VISA addresses

a = rm.open_resource("PASTE_SDG1032X_ADDRESS")  # Siglent SDG1032X
b = rm.open_resource("PASTE_AFG1022_ADDRESS")  # Tektronix AFG1022
for inst in (a, b):
    inst.timeout = 5000  # ms
    print(inst.query("*IDN?"))

# No shared setting with an example on both, so each uses its own command
a.write("C1:OUTP ON")  # Turn On Output
b.write("OUTPut1:STATe ON")  # Turn On Output

# No shared reading with an example on both, so each uses its own command
print(a.query("*TST?"))  # Self Test
print(b.query("SYSTem:ERRor?"))  # Read Error

a.close()
b.close()

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Siglent SDG1032X or Tektronix AFG1022 and writes the report from the measured results.

Get started

Frequently asked questions

What is the difference between the Siglent SDG1032X and the Tektronix AFG1022 for remote control?

In TestFlow's library the SDG1032X has 74 SCPI commands and the AFG1022 has 67 SCPI commands. 8 command headers are common to both, 17 are only on the SDG1032X (mostly C and IEEE 488.2 common (*)), and 48 are only on the AFG1022 (mostly SOURce and OUTPut).

Can I use the same SCPI code for the Siglent SDG1032X and the Tektronix AFG1022?

Partly. 8 command headers are accepted by both. 65 are not, for example C<Channel>:OUTP on the SDG1032X and SOURce<Channel>:FUNCtion:SHAPe on the AFG1022, so a script that uses those needs a separate branch for each instrument.

Which has more remote commands, the SDG1032X or the AFG1022?

The SDG1032X: 74 commands for the SDG1032X against 67 for the AFG1022 in TestFlow's library. Of those, 9 on the SDG1032X and 10 on the AFG1022 are queries that read a value or state, and the library splits them into 9 and 7 subsystems.

How do the SDG1032X and AFG1022 signal operation complete and report errors?

Only the SDG1032X library has an operation-complete command (*OPC?); the AFG1022 library has none. Only the AFG1022 library has an error-queue read (SYSTem:ERRor?); the SDG1032X library has none. Each command named here is listed in the tables on this page and on each instrument's command reference.