Vector Signal Generator · SCPI command comparison

Keysight E8267D vs Rohde & Schwarz SMW200A: SCPI commands and remote control compared

In TestFlow's instrument library, the Keysight E8267D takes 130 SCPI commands, 39 of them queries, and the Rohde & Schwarz SMW200A takes 126 SCPI commands, 54 of them queries. That is 4 more on the E8267D. Counting distinct command headers (the command path without its arguments), 37 are accepted by both, 73 exist only on the E8267D, and 77 only on the SMW200A. 34% of the E8267D's command headers also exist on the SMW200A.

Both libraries have commands under SOURce, OUTPut, and SYSTem. Only the E8267D has MMEMory. Only the SMW200A has TRIGger.

Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?.

E8267D commands
130
SMW200A commands
126
Shared headers
37
Unique headers
150

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Keysight E8267D or Rohde & Schwarz SMW200A and writes the report from the measured results.

Get started

E8267D vs SMW200A at a glance

Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.

Keysight E8267DRohde & Schwarz SMW200A
Commands in TestFlow's library130126
Queries (read a value or state)3954
Settings and actions9172
Subsystems85
Distinct command headers110114
Headers the other lacks7377
Command languageSCPISCPI
Operation complete*OPC?*OPC?
Error queueSYSTem:ERRor?SYSTem:ERRor?
Models on this command setE8267DSMW200A

Commands both accept

37 command headers are in both libraries. Here are 12, taken across subsystems.

CommandWhat it does
:SOURce:FREQuency:MODE <Mode>Set Frequency Mode. Sets the frequency entry mode (fixed CW value, analog sweep, or list).
:OUTPut:STATe ONTurn On RF Output. Enables the RF output signal.
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).
:SOURce:FREQuency:MODE?Read Frequency Mode. Reads the current frequency entry mode.
:OUTPut:STATe?Read RF Output State. Reads whether the RF output is currently ON or OFF.
*RSTReset. Resets the instrument to its default state.
:SOURce:FREQuency:CENTer <Freq>Set Frequency Center. Sets the center frequency of the sweep range in Hz.
*CLSClear Status. Clears all event registers and the error queue.
:SOURce:FREQuency:CENTer?Read Frequency Center. Reads the sweep center frequency in Hz.
*TST?Self Test. Runs the self-test and returns 0 for pass or 1 for failure.
:SOURce:FREQuency:SPAN <Freq>Set Frequency Span. Sets the span of the sweep range in Hz.
*OPC?Operation Complete. Returns 1 when all pending operations are complete.

Only on the Keysight E8267D

73 command headers in the E8267D library have no match in the SMW200A library. Below are 14 of them from the 5 largest subsystems; the full list is in the Keysight E8267D command reference.

SOURce (63 only on the E8267D)

CommandWhat it does
:SOURce:FREQuency:FIXed <Freq>Set Frequency. Sets the CW/fixed RF output frequency in Hz (100 kHz to 44 GHz depending on installed options).
:SOURce:FREQuency:FIXed?Read Frequency. Reads the current CW/fixed RF output frequency in Hz.
:SOURce:FREQuency:MANual <Freq>Set Frequency Manual. Sets the frequency output when the sweep is in manual mode.
:SOURce:FREQuency:MANual?Read Frequency Manual. Reads the manual sweep frequency in Hz.

IEEE 488.2 common (*) (3 only on the E8267D)

CommandWhat it does
*SAV <Register>,<Sequence>Save State Slot. Saves the current instrument state to an internal register.
*RCL <Register>,<Sequence>Recall State Slot. Recalls the instrument state from an internal register.
*OPT?Read Options. Returns the list of options installed in the instrument.

OUTPut (3 only on the E8267D)

CommandWhat it does
:OUTPut:MODulation:STATe ONTurn On Modulation. Enables the modulation of the RF output signal.
:OUTPut:MODulation:STATe?Read Modulation State. Reads whether RF modulation is enabled.
:OUTPut:PROTection:STATe ONTurn On Output Protection. Enables the reverse power protection on the RF output.

MMEMory (2 only on the E8267D)

CommandWhat it does
:MMEMory:DELete <File>Delete File. Deletes the named file from instrument memory.
:MMEMory:CATalog?List Files. Lists the files in the current instrument directory.

SYSTem (2 only on the E8267D)

CommandWhat it does
:SYSTem:ERRor:NEXt?Read Error. Reads and removes the next entry from the error queue.
:SYSTem:PRESetSystem Preset. Returns the instrument to its preset state.

Only on the Rohde & Schwarz SMW200A

77 command headers in the SMW200A library have no match in the E8267D library. Below are 12 of them from the 4 largest subsystems; the full list is in the Rohde & Schwarz SMW200A command reference.

SOURce (68 only on the SMW200A)

CommandWhat it does
SOURce:FREQuency:CW <Freq>Set Frequency. Sets the frequency of the RF output signal in CW/fixed mode in Hz (300 kHz to instrument max, depends on installed options).
SOURce:FREQuency:CW?Read Frequency. Reads the current CW/fixed RF output frequency in Hz.
SOURce:FREQuency:OFFSet?Read Frequency Offset. Reads the current RF frequency offset value in Hz.
SOURce:POWer:STARt?Read Power Start. Reads the start level of the RF power sweep range.

OUTPut (5 only on the SMW200A)

CommandWhat it does
OUTPut:STATe:PON <Pon>Set Power On Output State. Defines the state of the RF output signal when the instrument is switched on.
OUTPut:STATe:PON?Read Power On Output State. Reads the configured RF output state used at power-on.
OUTPut:ALL:STATe ONTurn On All RF Outputs. Enables all RF output signals of the instrument (all installed paths).
OUTPut:AMODe MANualSet Attenuator Mode Manual. Sets the RF output attenuator to manual mode so the attenuation value can be fixed.

SYSTem (2 only on the SMW200A)

CommandWhat it does
SYSTem:ERRor:ALL?Read Error Queue. Queries and clears all unread entries from the error/event queue; returns 0,'No error' if the queue is empty.
SYSTem:ERRor:COUNt?Read Error Count. Reads the number of entries currently in the error/event queue.

TRIGger (2 only on the SMW200A)

CommandWhat it does
TRIGger:FSWeep:SOURce <Source>Set Frequency Sweep Trigger Source. Selects the trigger source for the RF frequency sweep (free-running, single/bus, external, or external-auto).
TRIGger:FSWeep:SOURce?Read Frequency Sweep Trigger Source. Reads the current RF frequency sweep trigger source.

Control both from Python

With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, both libraries hold :OUTPut:STATe (turn on rf output), and the same line runs on each. For the reading, both libraries hold :OUTPut:STATe? (read rf output state), and the same line runs on each. For the basics, see the PyVISA tutorial.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find both VISA addresses

a = rm.open_resource("PASTE_E8267D_ADDRESS")  # Keysight E8267D
b = rm.open_resource("PASTE_SMW200A_ADDRESS")  # Rohde & Schwarz SMW200A
for inst in (a, b):
    inst.timeout = 5000  # ms
    print(inst.query("*IDN?"))

# The same setting on both: Turn On RF Output
a.write(":OUTPut:STATe ON")
b.write("OUTPut:STATe ON")

# The same reading on both: Read RF Output State
print(a.query(":OUTPut:STATe?"))
print(b.query("OUTPut:STATe?"))

a.close()
b.close()

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Keysight E8267D or Rohde & Schwarz SMW200A and writes the report from the measured results.

Get started

Frequently asked questions

What is the difference between the Keysight E8267D and the Rohde & Schwarz SMW200A for remote control?

In TestFlow's library the E8267D has 130 SCPI commands and the SMW200A has 126 SCPI commands. 37 command headers are common to both, 73 are only on the E8267D (mostly SOURce and IEEE 488.2 common (*)), and 77 are only on the SMW200A (mostly SOURce and OUTPut).

Can I use the same SCPI code for the Keysight E8267D and the Rohde & Schwarz SMW200A?

Partly. 37 command headers are accepted by both, including :SOURce:FREQuency:MODE, :OUTPut:STATe, and :SOURce:FREQuency:MODE?. 150 are not, for example :SOURce:FREQuency:FIXed on the E8267D and SOURce:FREQuency:CW on the SMW200A, so a script that uses those needs a separate branch for each instrument.

Which has more remote commands, the E8267D or the SMW200A?

The E8267D: 130 commands for the E8267D against 126 for the SMW200A in TestFlow's library. Of those, 39 on the E8267D and 54 on the SMW200A are queries that read a value or state, and the library splits them into 8 and 5 subsystems.

How do the E8267D and SMW200A signal operation complete and report errors?

Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?. Each command named here is listed in the tables on this page and on each instrument's command reference.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.