Vector Network Analyzer · SCPI command comparison

Anritsu MS46122A vs Keysight E5061B: SCPI commands and remote control compared

In TestFlow's instrument library, the Anritsu MS46122A takes 57 SCPI commands, 14 of them queries, and the Keysight E5061B takes 58 SCPI commands, 14 of them queries. That is 1 more on the E5061B. Counting distinct command headers (the command path without its arguments), 43 are accepted by both, 5 exist only on the MS46122A, and 6 only on the E5061B. 90% of the MS46122A's command headers also exist on the E5061B.

Both libraries have commands under SENSe, CALCulate, SYSTem, DISPlay, MMEMory, SOURce, TRIGger, and INITiate. Only the E5061B has OUTPut.

Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?.

TestFlow's library gives the MS46122B, MS46131A, MS46322A, and MS46322B the same command set as the MS46122A, so the MS46122A column applies to them too.

MS46122A commands
57
E5061B commands
58
Shared headers
43
Unique headers
11

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Anritsu MS46122A or Keysight E5061B and writes the report from the measured results.

Get started

MS46122A vs E5061B at a glance

Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.

Anritsu MS46122AKeysight E5061B
Commands in TestFlow's library5758
Queries (read a value or state)1414
Settings and actions4344
Subsystems1213
Distinct command headers4849
Headers the other lacks56
Command languageSCPISCPI
Operation complete*OPC?*OPC?
Error queueSYSTem:ERRor?SYSTem:ERRor?
Models on this command setMS46122A, MS46122B, MS46131A, MS46322A, MS46322BE5061B

Commands both accept

43 command headers are in both libraries. Here are 12, taken across subsystems. Where the E5061B library writes the command differently, its form is shown under the MS46122A's.

CommandWhat it does
SENSe:FREQuency:STARt <Frequency>Set Start Freq. Sets the sweep start frequency in Hz.
CALCulate:PARameter<Trace>:DEFine <Parameter>Define Measurement. Creates a new measurement trace with the given name and S-parameter.
SYSTem:PRESetPreset. Presets the analyzer to its default measurement state.
DISPlay:WINDow:TRACe:Y:SCALe:PDIVision <Per_Div>Set Y Scale. Sets the vertical scale per division for the active trace.
MMEMory:STORe '<Filename>'Save State. Saves the instrument state/data to the named file.
SOURce:POWer <Power>Set Power Level. Sets the source output power level in dBm.
TRIGger:SOURce <Source>Set Trigger Source. Sets the trigger source for the sweep.
INITiate:CONTinuous ONContinuous On. Enables continuous (free-run) triggering.
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).
SENSe:FREQuency:STOP <Frequency>Set Stop Freq. Sets the sweep stop frequency in Hz.
CALCulate:PARameter<Trace>:SELectE5061B: CALCulate:PARameter<Number>:SELectSelect By Number. Selects the active measurement by its trace number.
SYSTem:ERRor?Read Error. Reads the next message from the error queue.

Only on the Anritsu MS46122A

5 command headers in the MS46122A library have no match in the E5061B library. Below are 5 of them from the 5 largest subsystems; the full list is in the Anritsu MS46122A command reference.

CALCulate (1 only on the MS46122A)

CommandWhat it does
CALCulate:MARKer<Marker>:ACTivate ; ...Marker Search Max. Moves the marker to the trace maximum.

DISPlay (1 only on the MS46122A)

CommandWhat it does
DISPlay:WINDow:TRACe:Y:AUTOAutoscale. Autoscales the active trace to fit the display.

SENSe (1 only on the MS46122A)

CommandWhat it does
SENSe:SWEep:TYPe <Type>Set Sweep Type. Sets the sweep type (linear, log, segment, power, or CW).

SYSTem (1 only on the MS46122A)

CommandWhat it does
SYSTem:HOLD:RF ONRF Power On. Turns the RF source power output on.

TRIGger (1 only on the MS46122A)

CommandWhat it does
TRIGger:SINGleTrigger Single. Triggers a single sweep when not in continuous mode.

Only on the Keysight E5061B

6 command headers in the E5061B library have no match in the MS46122A library. Below are 6 of them from the 5 largest subsystems; the full list is in the Keysight E5061B command reference.

SENSe (2 only on the E5061B)

CommandWhat it does
SENSe:SWEep:TYPE <Type>Set Sweep Type. Sets the sweep type (linear, log, segment, power, or CW).
SENSe:SWEep:TIME <Seconds>Set Sweep Time. Sets the sweep time in seconds.

CALCulate (1 only on the E5061B)

CommandWhat it does
CALCulate:MARKer<Marker>:FUNCtion:TYPE MAXimum ; ...Marker Search Max. Moves the marker to the trace maximum.

DISPlay (1 only on the E5061B)

CommandWhat it does
DISPlay:WINDow:TRACe:Y:SCALe:AUTOAutoscale. Autoscales the active trace to fit the display.

INITiate (1 only on the E5061B)

CommandWhat it does
INITiate:IMMediateTrigger Single. Triggers a single sweep when not in continuous mode.

OUTPut (1 only on the E5061B)

CommandWhat it does
OUTPut:STATe ONRF Power On. Turns the RF source power output on.

Control both from Python

With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, both libraries hold SENSe:AVERage:STATe (average on), and the same line runs on each. For the reading, both libraries hold SENSe:FREQuency:STARt? (read start freq), and the same line runs on each. For the basics, see the PyVISA tutorial.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find both VISA addresses

a = rm.open_resource("PASTE_MS46122A_ADDRESS")  # Anritsu MS46122A
b = rm.open_resource("PASTE_E5061B_ADDRESS")  # Keysight E5061B
for inst in (a, b):
    inst.timeout = 5000  # ms
    print(inst.query("*IDN?"))

# The same setting on both: Average On
a.write("SENSe:AVERage:STATe ON")
b.write("SENSe:AVERage:STATe ON")

# The same reading on both: Read Start Freq
print(a.query("SENSe:FREQuency:STARt?"))
print(b.query("SENSe:FREQuency:STARt?"))

a.close()
b.close()

Run this on your bench

Describe the test; TestFlow's agent uses these command sets to drive your Anritsu MS46122A or Keysight E5061B and writes the report from the measured results.

Get started

Frequently asked questions

What is the difference between the Anritsu MS46122A and the Keysight E5061B for remote control?

In TestFlow's library the MS46122A has 57 SCPI commands and the E5061B has 58 SCPI commands. 43 command headers are common to both, 5 are only on the MS46122A (mostly CALCulate and DISPlay), and 6 are only on the E5061B (mostly SENSe and CALCulate).

Can I use the same SCPI code for the Anritsu MS46122A and the Keysight E5061B?

Partly. 43 command headers are accepted by both, including SENSe:FREQuency:STARt, CALCulate:PARameter<Trace>:DEFine, and SYSTem:PRESet. 11 are not, for example CALCulate:MARKer<Marker>:ACTivate on the MS46122A and SENSe:SWEep:TYPE on the E5061B, so a script that uses those needs a separate branch for each instrument.

Which has more remote commands, the MS46122A or the E5061B?

The E5061B: 57 commands for the MS46122A against 58 for the E5061B in TestFlow's library. Of those, 14 on the MS46122A and 14 on the E5061B are queries that read a value or state, and the library splits them into 12 and 13 subsystems.

How do the MS46122A and E5061B signal operation complete and report errors?

Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?. Each command named here is listed in the tables on this page and on each instrument's command reference.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.