Radio Test Set · SCPI command reference

Astronics R8000C, R8100, and R8200 SCPI commands

The Astronics R8000C, R8100, and R8200 radio test set is controlled remotely with SCPI commands. TestFlow's instrument library holds 116 commands for it, 34 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the R8000C on a real bench.

Commands
116
Queries
34
Subsystems
11
Models covered
3

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Astronics R8000C, R8100, or R8200 and writes the report from the measured results.

Get started

Control the Astronics R8000C from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the Astronics R8000C's VISA address

# Paste the address of your Astronics R8000C (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("SET SETUP:Auto Attn=On")  # Turn On Auto Attenuation
print(inst.query("GET METER:Measured Power"))  # Read Measured Power

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your Astronics R8000C, R8100, or R8200 and writes the report from the measured results.

Get started

Run a R8000C test without writing code

Describe the test in a sentence, for example “turn on auto attenuation on the R8000C, then read measured power and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

116 commands in 11 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The R8000C, R8100, and R8200 share this command set in TestFlow's library.

SET subsystem (66)

CommandWhat it doesArguments
SET TEST:Test Mode=<Mode>Set Test Mode. Selects the test mode (options required for digital modes).Text: Standard,DMR,PROJECT 25,P25 Trunk,NXDN,NXDN Trunk,TETRA Base Station,TETRA DMO,TETRA TMO,DPMR,P25 II,PTC-ITCR,PTC-ACSES,AVIONICS
SET SYSTEM:Mode Request=<Mode>Set Operating Mode. Requests the operating mode.Text: Monitor,Generate,Duplex
SET RF:RF Power=OnTurn On RF Power. Turns the RF generator output on (Generate/Duplex modes).None
SET RF:RF Power=OffTurn Off RF Power. Turns the RF generator output off.None
SET RF:Monitor Frequency=<Freq>Set Monitor Frequency. Sets the monitor (receive) frequency; value may include units Hz/kHz/MHz/GHz (250 kHz minimum; maximum per model).Text
SET RF:Generate Frequency=<Freq>Set Generate Frequency. Sets the generate frequency; value may include units Hz/kHz/MHz/GHz.Text
SET RF:Duplex Offset=<Offset>Set Duplex Offset. Sets the duplex offset; value may include units Hz/kHz/MHz/GHz.Text
SET RF:Output Level=<Level>Set Output Level. Sets the RF output level in dBm (-130 to 5 dBm).Number: -130,5
SET RF:Output Lvl Units=<Units>Set Output Level Units. Sets the RF output level units.Text: dBm,Volts,mV,uV,Watts,mW,uW
SET RF:Modulation Type=<Mod>Set Modulation Type. Sets the modulation type (available values depend on test mode/options).Text: FM,AM,USB,LSB,4FSK,C4FM,LSM,WCQPSK,PI/4 DQPSK,HCPM,HDQPSK
SET RF:Generate Port=<Port>Set Generate Port. Selects the generator port.Text: RF In/Out,Gen Out
SET RF:Monitor Port=<Port>Set Monitor Port. Selects the monitor port.Text: RF In/Out,Antenna
SET RF:Bandwidth=<BW>Set IF Bandwidth. Sets the receiver IF bandwidth.Text: 6.25 kHz (Narrow),8.33 kHz (Narrow),10 kHz (Narrow),12.5 kHz (Narrow),25 kHz (Wide),50 kHz (Wide),100 kHz (Wide),200 kHz (Wide)
SET RF:Attenuation=<Atten>Set Attenuation. Sets the input attenuation (0 dB to 62 dB in 2 dB steps), e.g. '20 dB'.Text
SET RF:PreAmp On=OnTurn On Preamp. Turns the receiver pre-amplifier on.None
SET RF:PreAmp On=OffTurn Off Preamp. Turns the receiver pre-amplifier off.None
SET RF:Input Lvl Units=<Units>Set Input Level Units. Sets the RF input level units.Text: dBm,Volts,mV,uV,Watts,mW,uW
SET RF:Frequency Error Units=<Units>Set Frequency Error Units. Sets the frequency error units.Text: Hertz,PPM
SET AUDIO:Tone A Frequency=<Freq>Set Tone A Frequency. Sets the Tone A frequency in Hz (0 to 20000 Hz).Number: 0,20000
SET AUDIO:Tone A=<Volts>Set Tone A Level. Sets the Tone A audio output level in V (0 to 8 V).Number: 0,8
SET AUDIO:Gen Tone A=<kHz>Set Tone A FM Level. Sets the Tone A modulation level in kHz deviation (0 to 100 kHz).Number: 0,100
SET AUDIO:Gen AM Tone A=<Percent>Set Tone A AM Level. Sets the Tone A AM modulation level in percent (0 to 99%).Number: 0,99
SET AUDIO:Tone A Mode=<Mode>Set Tone A Mode. Sets the Tone A mode.Text: Off,Continuous,Burst
SET AUDIO:Tone B Frequency=<Freq>Set Tone B Frequency. Sets the Tone B frequency in Hz (0 to 20000 Hz).Number: 0,20000
SET AUDIO:Tone B=<Volts>Set Tone B Level. Sets the Tone B audio output level in V (0 to 8 V).Number: 0,8
SET AUDIO:Gen Tone B=<kHz>Set Tone B FM Level. Sets the Tone B modulation level in kHz deviation (0 to 100 kHz).Number: 0,100
SET AUDIO:Tone B Mode=<Mode>Set Tone B Mode. Sets the Tone B mode.Text: Off,Continuous,Burst
SET AUDIO:Fixed 1kHz Mode=<Mode>Set Fixed 1kHz Mode. Sets the fixed 1 kHz tone mode.Text: Off,Continuous
SET AUDIO:Gen Fixed 1kHz=<kHz>Set Fixed 1kHz FM Level. Sets the fixed 1 kHz modulation level in kHz deviation (0 to 100 kHz).Number: 0,100
SET AUDIO:Gen AM Fixed 1kHz=<Percent>Set Fixed 1kHz AM Level. Sets the fixed 1 kHz AM modulation level in percent (0 to 99%).Number: 0,99
SET AUDIO:Fixed 1kHz=<Volts>Set Fixed 1kHz Level. Sets the fixed 1 kHz audio output level in V (0 to 8 V).Number: 0,8
SET AUDIO:Format=<Format>Set Synth Format. Sets the synthesizer audio format.Text: PL,DPL,DPL Invert,A/B Sequence,5/6 Tone,POCSAG,General Sequence
SET AUDIO:Synth Mode=<Mode>Set Synth Mode. Sets the synthesizer mode.Text: Off,Continuous,Burst,Disconnect Tone
SET AUDIO:PL Code=<Code>Set PL Code. Sets the PL (CTCSS) code, e.g. XZ, WZ, 1A.Text
SET AUDIO:DPL Code=<Code>Set DPL Code. Sets the DPL (DCS) code, e.g. 023.Text
SET AUDIO:Gen Synth=<kHz>Set Synth FM Level. Sets the synthesizer modulation level in kHz deviation (0 to 100 kHz).Number: 0,100
SET AUDIO:DTMF Code=<Code>Set DTMF Code. Sets the DTMF code string (0-9, A-D, #, *).Text
SET AUDIO:DTMF Mode=<Mode>Set DTMF Mode. Sets the DTMF mode.Text: Off,Continuous,Burst
SET AUDIO:Microphone Mode=<Mode>Set Microphone Mode. Sets the microphone modulation mode.Text: Off,Continuous
SET AUDIO:Mod In Mode=<Mode>Set Mod In Mode. Sets the Mod In port mode.Text: Off,Continuous
SET AUDIO:High Pass Filter=<Filter>Set Audio High Pass Filter. Sets the audio high-pass filter.Text: 1 Hz,300 Hz,3 kHz,None
SET AUDIO:Low Pass Filter=<Filter>Set Audio Low Pass Filter. Sets the audio low-pass filter.Text: 300 Hz,3 kHz,20 kHz
SET AUDIO:Audio Output Load=<Ohms>Set Audio Output Load. Sets the audio output load in ohms (1 to 10000).Number: 1,10000
SET METER:Subzone=<Meter>Select Meter. Selects the meter shown in the METER zone.Text: Power Meter,Voltmeter,SINAD/Distortion,Decoder,Frequency Counter,RF Scan,SNRMeter,Current Meter
SET METER:PWR Meter Range=<Range>Set Power Meter Range. Sets the power meter range.Text: 5W,10W,50W,150W
SET METER:Voltmeter=<Mode>Set Voltmeter Mode. Selects the voltmeter mode.Text: AC Volts,DC Volts
SET METER:Audio Meter=<Meas>Set Audio Meter. Selects the audio measurement.Text: SINAD/Ext Distortion,Internal Distortion
SET METER:Resolution=<Res>Set Counter Resolution. Sets the frequency counter resolution.Text: 0.001 Hz,0.01 Hz,0.1 Hz,1.0 Hz,10 Hz
SET METER:Decoder=<Decoder>Set Decoder Type. Selects the decoder type.Text: PL/Period Counter,DPL Decode,DTMF Decode,2-Tone Decode,5/6 Tone Decode,General Sequence
SET SPEC_AN:Monitor Frequency=<Freq>Set SA Center Frequency. Sets the spectrum analyzer center frequency (units Hz/kHz/MHz/GHz).Text
SET SPEC_AN:Span=<Span>Set SA Span. Sets the spectrum analyzer span (units Hz/kHz/MHz/GHz).Text
SET SPEC_AN:Reference Level=<Level>Set SA Reference Level. Sets the reference level in dBm (-120 to 90).Number: -120,90
SET SPEC_AN:Vertical Scale=<Scale>Set SA Vertical Scale. Sets the vertical scale.Text: 10 dB/div,5 dB/div,2 dB/div,1 dB/div
SET SPEC_AN:Display Mode=<Mode>Set SA Display Mode. Sets the display mode.Text: Normal,Freeze,Max Hold,Average
SET SPEC_AN:Detector=<Det>Set SA Detector. Sets the detector.Text: Power,Peak,Sample,Mean,Valley
SET SPEC_AN:OBW=OnTurn On SA OBW. Turns the occupied bandwidth measurement on.None
SET SPEC_AN:OBW=OffTurn Off SA OBW. Turns the occupied bandwidth measurement off.None
SET SETUP:Analog Msr Averaging=OnTurn On Analog Averaging. Turns analog measurement averaging on.None
SET SETUP:Analog Msr Averaging=OffTurn Off Analog Averaging. Turns analog measurement averaging off.None
SET SETUP:Analog Msr Avg Samples=<Samples>Set Analog Averaging Samples. Sets the analog averaging samples (2 to 100).Number: 2,100
SET SETUP:Auto Attn=OnTurn On Auto Attenuation. Turns automatic attenuation on.None
SET SETUP:Auto Attn=OffTurn Off Auto Attenuation. Turns automatic attenuation off.None
SET SETUP:RF Level Offset=OnTurn On RF Level Offset. Turns the RF level offset on.None
SET SETUP:RF Level Offset=OffTurn Off RF Level Offset. Turns the RF level offset off.None
SET SETUP:RF In/Out Offset=<dB>Set RF InOut Offset. Sets the RF In/Out offset in dB (-99 to 99).Number: -99,99
SET SETUP:Ref Clock Mode=<Mode>Set Ref Clock Mode. Sets the reference clock mode.Text: Output,Input

GET subsystem (32)

CommandWhat it doesArguments
GET TEST:Test ModeRead Test Mode. Returns the current test mode.None
GET SYSTEM:ModeRead Operating Mode. Returns the operating mode (Monitor, Generate, Duplex, Track Gen, Cable Fault, VNA).None
GET SYSTEM:StateRead System State. Returns the system state (INIT, RUN, LOAD, CALIBRATE).None
GET RF:RF PowerRead RF Power State. Returns the RF generator output state (Off/On).None
GET RF:Monitor FrequencyRead Monitor Frequency. Returns the monitor frequency.None
GET RF:Generate FrequencyRead Generate Frequency. Returns the generate frequency.None
GET RF:Output LevelRead Output Level. Returns the RF output level in dBm.None
GET RF:Modulation TypeRead Modulation Type. Returns the modulation type.None
GET RF:RX OverloadRead RX Overload. Returns the receiver overload status.None
GET MONITOR:Frequency ErrorRead Frequency Error. Returns the measured frequency error in Hz.None
GET MONITOR:Frequency Error PPMRead Frequency Error PPM. Returns the measured frequency error in PPM.None
GET MONITOR:Input LevelRead Input Level. Returns the measured RF input level.None
GET MONITOR:Deviation+Read Deviation Positive. Returns the measured positive deviation.None
GET MONITOR:Deviation-Read Deviation Negative. Returns the measured negative deviation.None
GET SYSTEM:Squelch StateRead Squelch State. Returns the squelch state.None
GET METER:Measured PowerRead Measured Power. Returns the measured RF power (Power Meter subzone).None
GET METER:AC VoltsRead AC Volts. Returns the AC voltmeter reading.None
GET METER:DC VoltsRead DC Volts. Returns the DC voltmeter reading.None
GET METER:SINADRead SINAD. Returns the SINAD reading (SINAD/Distortion subzone).None
GET METER:External DistortionRead External Distortion. Returns the external distortion reading.None
GET METER:Internal DistortionRead Internal Distortion. Returns the internal distortion reading.None
GET METER:SNRRead Audio SNR. Returns the audio SNR in dB (SNRMeter subzone).None
GET METER:Frequency CounterRead Frequency Counter. Returns the audio frequency counter reading.None
GET METER:PL FrequencyRead PL Frequency. Returns the decoded PL frequency.None
GET METER:DPL CodeRead DPL Code. Returns the decoded DPL code.None
GET METER:DTMF CodeRead DTMF Code. Returns the decoded DTMF code.None
GET METER:Ext AmpsRead External Current. Returns the external current reading in A (Current Meter subzone).None
GET SPEC_AN:Resolution BandwidthRead SA Resolution Bandwidth. Returns the resolution bandwidth.None
GET DISPLAY:Spectral DataRead Spectral Data. Returns the spectrum sample array.None
GET SYSTEM:UNITIDRead Serial Number. Returns the serial number.None
GET ABOUT:SystemVersionRead System Version. Returns the system version.None
GET OPTIONS:EnabledRead Enabled Options. Returns the enabled options.None

GO subsystem (6)

CommandWhat it doesArguments
GO SYSTEM:RFGo RF Zone. Navigates to the RF zone menu.None
GO SYSTEM:AUDIOGo Audio Zone. Navigates to the AUDIO zone menu.None
GO SYSTEM:METERGo Meter Zone. Navigates to the METER zone menu.None
GO SYSTEM:DISPLAYGo Display Zone. Navigates to the DISPLAY zone menu.None
GO INSTRUMENTS:SPEC_ANGo Spectrum Analyzer. Navigates to the spectrum analyzer instrument.None
GO INSTRUMENTS:O_SCOPEGo Oscilloscope. Navigates to the oscilloscope instrument.None

DO subsystem (5)

CommandWhat it doesArguments
DO RF:Copy Mon to GenCopy Monitor To Generate. Copies the monitor frequency to the generator.None
DO RF:Copy Gen to MonCopy Generate To Monitor. Copies the generate frequency to the monitor.None
DO METER:ResetReset Decoder. Resets the decoder / frequency counter.None
DO SPEC_AN:Find PeakSA Find Peak. Finds the peak on the spectrum display.None
DO PRESETS:Load DefaultsLoad Factory Defaults. Loads the factory configuration.None

ERR subsystem (1)

CommandWhat it doesArguments
ERR?Read Errors. Returns the active popup or message codes.None

CLEAR subsystem (1)

CommandWhat it doesArguments
CLEARClear Errors. Acknowledges active error messages (no popup active).None

NOOP subsystem (1)

CommandWhat it doesArguments
NOOPNo Operation. No-operation; used to poll for a Busy (2) response.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (1)

CommandWhat it doesArguments
*IDN?Identify. Returns the equipment ID (manufacturer, model, serial number, system version).None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from Astronics's programming documentation for the R8000C, R8100, and R8200 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by Astronics's programming manual: check it before you rely on an edge case. Last updated September 27, 2026.

Frequently asked questions

Does the Astronics R8000C support SCPI remote control?

Yes. The Astronics R8000C accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 116 SCPI commands for it: 34 queries that read values or state, and 82 settings and actions.

How do I control the Astronics R8000C from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SET SETUP:Auto Attn=On and GET METER:Measured Power.

Which command reads a value from the Astronics R8000C?

GET METER:Measured Power (read measured power). Returns the measured RF power (Power Meter subzone). The full list of queries is in the command reference on this page, grouped by subsystem.

Can I automate the Astronics R8000C without writing code?

Yes. TestFlow is an AI agent for electronics testing: you describe the test, and it builds the automation from this command library, runs it on the Astronics R8000C through the TestFlow desktop app, and writes the report from the measured results.

Your next test, automated today

Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.