Phase Noise Analyzer · SCPI command reference

AnaPico APPH20G, APPH40G, and APPH6040 SCPI commands

The AnaPico APPH20G, APPH40G, and APPH6040 phase noise analyzer is controlled remotely with SCPI commands. TestFlow's instrument library holds 184 commands for it, 67 of them queries that read values or state, grouped below by subsystem with their arguments. It is the same library TestFlow's AI agent uses to drive the APPH20G on a real bench.

Commands
184
Queries
67
Subsystems
10
Models covered
3

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your AnaPico APPH20G, APPH40G, or APPH6040 and writes the report from the measured results.

Get started

Control the AnaPico APPH20G from Python

With PyVISA, any VISA backend, and the instrument on USB, LAN or GPIB, this opens a session, identifies the instrument, sends one setting, and reads one value. Every command in it comes from the reference below. For a full walkthrough, see the PyVISA tutorial and the SCPI command cheat sheet.

import pyvisa

rm = pyvisa.ResourceManager()
print(rm.list_resources())  # find the AnaPico APPH20G's VISA address

# Paste the address of your AnaPico APPH20G (USB, LAN or GPIB).
inst = rm.open_resource("PASTE_VISA_ADDRESS_HERE")
inst.timeout = 5000  # ms

print(inst.query("*IDN?"))  # identify the instrument
inst.write("SENSe:FREQuency:EXECute")  # Start Frequency Search
print(inst.query("SENSe:MODE?"))  # Read Measurement Mode

inst.close()

Run this on your bench

Describe the test; TestFlow's agent uses this command set to drive your AnaPico APPH20G, APPH40G, or APPH6040 and writes the report from the measured results.

Get started

Run a APPH20G test without writing code

Describe the test in a sentence, for example “start frequency search on the APPH20G, then read measurement mode and log it against a limit”. TestFlow's agent builds the steps from this command library, runs them on your bench through the TestFlow desktop app, and writes the report from the measured values. See AI test automation for lab instruments for how that works and where it stops.

Get started

SCPI command reference

184 commands in 10 groups. A ? marks a query that returns a value. Placeholders in angle brackets take the listed values. The APPH20G, APPH40G, and APPH6040 share this command set in TestFlow's library.

Sense (SENSe) (97)

CommandWhat it doesArguments
SENSe:MODE <Mode>Set Measurement Mode. Selects the measurement mode: PN phase noise / VCO characterization / AN amplitude noise / FN frequency-noise based phase noise (BB and TRAN not yet available; *RST PN).Text: PN,VCO,AN,FN,BB,TRAN
SENSe:MODE?Read Measurement Mode. Returns the active measurement mode.None
SENSe:FREQuency:EXECuteStart Frequency Search. Starts the carrier frequency search (followed automatically by a power measurement); read results with CALCulate:FREQuency? and CALCulate:POWer?.None
SENSe:POWer:EXECuteStart Power Measurement. Starts the carrier power measurement; read the result with CALCulate:POWer?.None
SENSe:PN:FREQuency <Frequency>Set Carrier Frequency. Sets the DUT (carrier) frequency in Hz used when automatic frequency search is off (APPH20G: 1 MHz to 26 GHz with internal references; *RST 100 MHz).Number
SENSe:PN:FREQuency?Read Carrier Frequency. Returns the DUT (carrier) frequency in Hz.None
SENSe:PN:FREQuency:AUTO ONAuto Frequency Search On. Turns the automatic frequency search at the start of the measurement on.None
SENSe:PN:FREQuency:AUTO OFFAuto Frequency Search Off. Turns the automatic frequency search at the start of the measurement off.None
SENSe:PN:FREQuency:DETect <Mode>Set Frequency Search Mode. Sets how often the automatic frequency search is performed (ALWays every measurement / ONCe since startup / NEVer).Text: ALWays,ONCe,NEVer
SENSe:PN:FREQuency:STARt <Frequency>Set Start Offset. Sets the start offset frequency in Hz (*RST 10 Hz).Number
SENSe:PN:FREQuency:STARt?Read Start Offset. Returns the start offset frequency in Hz.None
SENSe:PN:FREQuency:STOP <Frequency>Set Stop Offset. Sets the stop offset frequency in Hz (*RST 100 MHz).Number
SENSe:PN:FREQuency:STOP?Read Stop Offset. Returns the stop offset frequency in Hz.None
SENSe:PN:PPD <Points>Set Points Per Decade. Sets the number of points per decade of the resulting trace (1 to 500; *RST 250).Number: 1,500
SENSe:PN:PPD?Read Points Per Decade. Returns the number of points per decade of the resulting trace.None
SENSe:PN:AVERage <Count>Set Average Count. Sets the average count of the phase noise measurement (1 to 10000; *RST 1).Number: 1,10000
SENSe:PN:AVERage?Read Average Count. Returns the average count of the phase noise measurement.None
SENSe:PN:CORRelation <Count>Set Correlation Count. Sets the number of cross-correlations of the phase noise measurement (1 to 10000; *RST 1).Number: 1,10000
SENSe:PN:CORRelation?Read Correlation Count. Returns the number of cross-correlations of the phase noise measurement.None
SENSe:PN:REFerences <Reference>Set Reference. Selects the references: NORM standard internal / LN low noise internal (option LN) / EXT external (*RST NORM).Text: NORM,LN,EXT
SENSe:PN:REFerences?Read Reference. Returns the selected reference type.None
SENSe:PN:REFerences<Channel>:SENSitivity <Sensitivity>Set Reference Sensitivity. Sets the tuning sensitivity in Hz/V of the reference for channel 1 or 2 (0.1 to 500; *RST 10).Number: 1,2; Number: 0.1,500
SENSe:PN:REFerences<Channel>:SENSitivity?Read Reference Sensitivity. Returns the tuning sensitivity in Hz/V of the reference for channel 1 or 2.Number: 1,2
SENSe:PN:REFerences:SENSitivity:EXECuteExecute Reference Sensitivity. Executes the reference sensitivity determination (listed in the command table without further description).None
SENSe:PN:LOBandwidth <Bandwidth>Set PLL Bandwidth. Sets the PLL bandwidth in Hz (0.1 to 10000; *RST 1).Number: 0.1,10000
SENSe:PN:LOBandwidth?Read PLL Bandwidth. Returns the PLL bandwidth in Hz.None
SENSe:PN:LOBandwidth:AUTO ONAuto PLL Bandwidth On. Turns automatic selection of the optimal PLL bandwidth during the measurement on.None
SENSe:PN:LOBandwidth:AUTO OFFAuto PLL Bandwidth Off. Turns automatic selection of the optimal PLL bandwidth during the measurement off.None
SENSe:PN:KPHI <Kphi>Set Kphi. Sets the phase detector constant Kphi in rad/V (*RST 0).Number
SENSe:PN:KPHI?Read Kphi. Returns the phase detector constant Kphi in rad/V.None
SENSe:PN:KPHI:AUTO ONAuto Kphi On. Turns the automatic Kphi detection at the start of the measurement on.None
SENSe:PN:KPHI:AUTO OFFAuto Kphi Off. Turns the automatic Kphi detection at the start of the measurement off.None
SENSe:PN:KPHI:DETect <Mode>Set Kphi Detect Mode. Sets how often Kphi is automatically detected (ALWays / ONCe / NEVer; shown in the manual programming example).Text: ALWays,ONCe,NEVer
SENSe:PN:IFGain <Gain>Set IF Gain. Sets the IF gain in dB (0 to 60; *RST 0).Number: 0,60
SENSe:PN:IFGain?Read IF Gain. Returns the IF gain in dB.None
SENSe:PN:IFGain:AUTO ONAuto IF Gain On. Turns the automatic IF gain setting on.None
SENSe:PN:IFGain:AUTO OFFAuto IF Gain Off. Turns the automatic IF gain setting off.None
SENSe:PN:IFGain:DETect <Mode>Set IF Gain Detect Mode. Sets how often the IF gain is automatically determined (ALWays / ONCe / NEVer).Text: ALWays,ONCe,NEVer
SENSe:PN:FUNCtion:RANGe <Min>,<Max>Set Integration Range. Sets the min and max offset frequency in Hz used for jitter / integrated noise / Allan variance (0.1 to 50e6 each).Number: 0.1,50e6; Number: 0.1,50e6
SENSe:PN:SPURious:OMISsion ONSpur Omission On. Turns spur omission for the trace and statistical analysis on.None
SENSe:PN:SPURious:OMISsion OFFSpur Omission Off. Turns spur omission for the trace and statistical analysis off.None
SENSe:PN:SMOothing:APERture <Aperture>Set Smoothing Aperture. Sets the trace smoothing aperture in percent (0.05 to 20; *RST 0.05).Number: 0.05,20
SENSe:PN:SMOothing:APERture?Read Smoothing Aperture. Returns the trace smoothing aperture in percent.None
SENSe:PN:SMOothing:STATe ONTrace Smoothing On. Turns trace smoothing on.None
SENSe:PN:SMOothing:STATe OFFTrace Smoothing Off. Turns trace smoothing off.None
SENSe:PN:TEST <Definition>Set Test Set. Defines the test set as a comma-separated keyword list (O<offset> spot noise / F freq / P power / J jitter / I integrated PN / D residual PM udeg / R residual PM urad / M residual FM) e.g. O1e3,O1e6,F,J.Text
SENSe:PN:TEST?Read Test Set Definition. Returns the test set definition (not the results).None
SENSe:PN:RESetReset PN Measurement. Resets the phase noise measurement; configuration is kept but detect states are reset (ONCe active again).None
SENS:AN:FREQ:AUTO ONAN Auto Frequency Search On. Turns automatic frequency search for the AN measurement (manual programming example) on.None
SENS:AN:FREQ:AUTO OFFAN Auto Frequency Search Off. Turns automatic frequency search for the AN measurement (manual programming example) off.None
SENS:AN:FREQ:DET <Mode>Set AN Frequency Search Mode. Sets how often the AN frequency search is performed (ALWays / ONCe / NEVer; manual programming example).Text: ALWays,ONCe,NEVer
SENS:AN:RESReset AN Measurement. Resets the AN measurement configuration (manual programming example).None
SENS:AN:AVER <Count>Set AN Average Count. Sets the average count of the AN measurement (manual programming example).Number
SENS:AN:CORR <Count>Set AN Correlation Count. Sets the number of cross-correlations of the AN measurement (manual programming example).Number
SENS:AN:PPD <Points>Set AN Points Per Decade. Sets the points per decade of the AN trace (manual programming example).Number
SENS:AN:FREQ:STAR <Frequency>Set AN Start Offset. Sets the AN start offset frequency in Hz (manual programming example).Number
SENS:AN:FREQ:STOP <Frequency>Set AN Stop Offset. Sets the AN stop offset frequency in Hz (manual programming example).Number
SENS:AN:SPUR:THR <Threshold>Set AN Spur Threshold. Sets the AN spur detection threshold in dB (manual programming example).Number
SENS:AN:SPUR:OMIS ONAN Spur Omission On. Turns spur omission for the AN trace (manual programming example) on.None
SENS:AN:SPUR:OMIS OFFAN Spur Omission Off. Turns spur omission for the AN trace (manual programming example) off.None
SENS:AN:SMO:APER <Aperture>Set AN Smoothing Aperture. Sets the AN trace smoothing aperture in percent (manual programming example).Number
SENS:AN:SMO:STAT ONAN Trace Smoothing On. Turns AN trace smoothing (manual programming example) on.None
SENS:AN:SMO:STAT OFFAN Trace Smoothing Off. Turns AN trace smoothing (manual programming example) off.None
SENS:FN:FREQ:AUTO ONFN Auto Frequency Search On. Turns automatic frequency search for the FN measurement (manual programming example) on.None
SENS:FN:FREQ:AUTO OFFFN Auto Frequency Search Off. Turns automatic frequency search for the FN measurement (manual programming example) off.None
SENS:FN:FREQ:DET <Mode>Set FN Frequency Search Mode. Sets how often the FN frequency search is performed (ALWays / ONCe / NEVer; manual programming example).Text: ALWays,ONCe,NEVer
SENS:FN:RESReset FN Measurement. Resets the FN measurement configuration (manual programming example).None
SENS:FN:AVER <Count>Set FN Average Count. Sets the average count of the FN measurement (manual programming example).Number
SENS:FN:CORR <Count>Set FN Correlation Count. Sets the number of cross-correlations of the FN measurement (manual programming example).Number
SENS:FN:PPD <Points>Set FN Points Per Decade. Sets the points per decade of the FN trace (manual programming example).Number
SENS:FN:FREQ:STAR <Frequency>Set FN Start Offset. Sets the FN start offset frequency in Hz (manual programming example).Number
SENS:FN:FREQ:STOP <Frequency>Set FN Stop Offset. Sets the FN stop offset frequency in Hz (manual programming example).Number
SENS:FN:SPUR:THR <Threshold>Set FN Spur Threshold. Sets the FN spur detection threshold in dB (manual programming example).Number
SENS:FN:SPUR:OMIS ONFN Spur Omission On. Turns spur omission for the FN trace (manual programming example) on.None
SENS:FN:SPUR:OMIS OFFFN Spur Omission Off. Turns spur omission for the FN trace (manual programming example) off.None
SENS:FN:SMO:APER <Aperture>Set FN Smoothing Aperture. Sets the FN trace smoothing aperture in percent (manual programming example).Number
SENS:FN:SMO:STAT ONFN Trace Smoothing On. Turns FN trace smoothing (manual programming example) on.None
SENS:FN:SMO:STAT OFFFN Trace Smoothing Off. Turns FN trace smoothing (manual programming example) off.None
SENSe:VCO:TEST:FREQuency ONVCO Test Frequency On. Turns the frequency parameter of the VCO characterization on.None
SENSe:VCO:TEST:FREQuency OFFVCO Test Frequency Off. Turns the frequency parameter of the VCO characterization off.None
SENSe:VCO:TEST:ISUPply ONVCO Test Supply Current On. Turns the supply current parameter of the VCO characterization on.None
SENSe:VCO:TEST:ISUPply OFFVCO Test Supply Current Off. Turns the supply current parameter of the VCO characterization off.None
SENSe:VCO:TEST:KPUShing ONVCO Test Pushing On. Turns the pushing parameter of the VCO characterization on.None
SENSe:VCO:TEST:KPUShing OFFVCO Test Pushing Off. Turns the pushing parameter of the VCO characterization off.None
SENSe:VCO:TEST:KVCO ONVCO Test Kvco On. Turns the tune sensitivity (Kvco) parameter of the VCO characterization on.None
SENSe:VCO:TEST:KVCO OFFVCO Test Kvco Off. Turns the tune sensitivity (Kvco) parameter of the VCO characterization off.None
SENSe:VCO:TEST:PNoise ONVCO Test Phase Noise On. Turns the spot phase noise parameter of the VCO characterization on.None
SENSe:VCO:TEST:PNoise OFFVCO Test Phase Noise Off. Turns the spot phase noise parameter of the VCO characterization off.None
SENSe:VCO:TEST:POWer ONVCO Test Power On. Turns the power parameter of the VCO characterization on.None
SENSe:VCO:TEST:POWer OFFVCO Test Power Off. Turns the power parameter of the VCO characterization off.None
SENSe:VCO:TEST:PNoise:OFFSet <Offsets>Set VCO PN Offsets. Sets up to 4 comma-separated offset frequencies in Hz for the VCO spot phase noise (blank = 0 = disabled; *RST 10k,100k,1M,10M).Text
SENSe:VCO:TEST:PNoise:OFFSet<Select>?Read VCO PN Offset. Returns the VCO spot noise offset frequency in Hz for the selected offset (1 to 4).Number: 1,2,3,4
SENSe:VCO:TEST:PNoise:COUNt?Read VCO PN Offset Count. Returns the number of VCO spot noise offsets that are set.None
SENSe:VCO:TYPE <Type>Set VCO Type. Selects the DUT type: fast tuning VCO or slow tuning VCXO (*RST VCO).Text: VCO,VCXO
SENSe:VCO:VOLTage:POINts <Points>Set VCO Voltage Points. Sets the number of tune voltage points of the VCO characterization (*RST 10).Number
SENSe:VCO:VOLTage:STARt <Voltage>Set VCO Start Voltage. Sets the start tuning voltage in V (*RST 0).Number
SENSe:VCO:VOLTage:STOP <Voltage>Set VCO Stop Voltage. Sets the stop tuning voltage in V (*RST 5).Number

Calculate (CALCulate) (42)

CommandWhat it doesArguments
CALCulate:WAIT:AVERage ALLWait Measurement Complete. Blocks further SCPI requests until the measurement is complete (no timeout).None
CALCulate:WAIT:AVERage NEXTWait Next Iteration. Blocks further SCPI requests until the next iteration is complete (no timeout).None
CALCulate:WAIT:AVERage <Event>,<Timeout>Wait Measurement Event. Blocks until the event (NEXT / ALL / iteration number) occurs or the timeout in ms expires (timeout returns error -393416).Text: NEXT,ALL; Number
CALCulate:FREQuency?Read Detected Frequency. Returns the carrier frequency in Hz detected by the last frequency search.None
CALCulate:POWer?Read Detected Power. Returns the carrier power level in dBm detected by the last frequency search.None
CALCulate:PN:TRACe:FREQuency?Read PN Trace Frequency. Returns the offset frequency points in Hz of the most recent measurement as IEEE 488.2 block data (32-bit floats).None
CALCulate:PN:TRACe:NOISe?Read PN Trace Noise. Returns the phase noise points in dBc/Hz of the most recent measurement as block data.None
CALCulate:PN:TRACe:SPOT? <Offset>Measure PN Spot Noise. Returns the phase noise in dBc/Hz of the last measurement at the given offset frequency in Hz.Number
CALCulate:PN:TRACe:SPURious:FREQuency?Read PN Spur Frequencies. Returns the offset frequencies in Hz of the spurs in the active trace as block data.None
CALCulate:PN:TRACe:SPURious:POWer?Read PN Spur Powers. Returns the power values in dBc of the spurs in the active trace as block data.None
CALCulate:PN:TRACe:FUNCtion:JITTer?Measure RMS Jitter. Returns the RMS jitter in s of the current trace over the SENSe:PN:FUNCtion:RANGe offset range.None
CALCulate:PN:TRACe:FUNCtion:INTegral?Measure Integrated Phase Noise. Returns the integrated phase noise in dBc of the current trace over the SENSe:PN:FUNCtion:RANGe offset range.None
CALCulate:PN:TRACe:FUNCtion:AVARianceCalculate Allan Variance. Calculates the Allan variance of the current trace over the SENSe:PN:FUNCtion:RANGe offset range.None
CALCulate:PN:TRACe:FUNCtion:AVARiance:TAU?Read Allan Variance Tau. Returns the tau values in s of the calculated Allan variance as block data.None
CALCulate:PN:TRACe:FUNCtion:AVARiance:SIGMa?Read Allan Variance Sigma. Returns the sigma values of the calculated Allan variance as block data.None
CALCulate:PN:PRELiminary:AVERage?Read PN Preliminary Averages. Returns the number of averages of the current phase noise data saved on the device.None
CALCulate:PN:PRELiminary:CORRelation?Read PN Preliminary Correlations. Returns the number of cross-correlations of the current phase noise data saved on the device.None
CALCulate:PN:TEST?Read Test Set Results. Returns the comma-separated results of the test set defined with SENSe:PN:TEST from the last measurement.None
CALCulate:AN:TRACe:FREQuency?Read AN Trace Frequency. Returns the offset frequency values in Hz of the current AN measurement as block data.None
CALCulate:AN:TRACe:NOISe?Read AN Trace Noise. Returns the amplitude noise spectrum values in dBc/Hz of the current measurement as block data.None
CALCulate:AN:TRACe:SPOT? <Offset>Measure AN Spot Noise. Returns the amplitude noise value in dBc/Hz at the given offset frequency in Hz.Number
CALCulate:AN:TRACe:SPURious:FREQuency?Read AN Spur Frequencies. Returns the offset frequencies in Hz of the spurs in the active AN trace as block data.None
CALCulate:AN:TRACe:SPURious:POWer?Read AN Spur Powers. Returns the power values in dBc of the spurs in the active AN trace as block data.None
CALCulate:AN:PRELiminary:AVERage?Read AN Preliminary Averages. Returns the number of averages of the current preliminary AN result.None
CALCulate:AN:PRELiminary:CORRelation?Read AN Preliminary Correlations. Returns the number of cross-correlations of the current preliminary AN result.None
CALCulate:FN:TRACe:FREQuency?Read FN Trace Frequency. Returns the offset frequency values in Hz of the current FN measurement as block data.None
CALCulate:FN:TRACe:NOISe?Read FN Trace Noise. Returns the phase noise (FN mode) spectrum values in dBc/Hz of the current measurement as block data.None
CALCulate:FN:TRACe:SPOT? <Offset>Measure FN Spot Noise. Returns the phase noise (FN mode) value in dBc/Hz at the given offset frequency in Hz.Number
CALCulate:FN:TRACe:SPURious:FREQuency?Read FN Spur Frequencies. Returns the offset frequencies in Hz of the spurs in the active FN trace as block data.None
CALCulate:FN:TRACe:SPURious:POWer?Read FN Spur Powers. Returns the power values in dBc of the spurs in the active FN trace as block data.None
CALCulate:FN:PRELiminary:AVERage?Read FN Preliminary Averages. Returns the number of averages of the current preliminary FN result.None
CALCulate:FN:PRELiminary:CORRelation?Read FN Preliminary Correlations. Returns the number of cross-correlations of the current preliminary FN result.None
CALCulate:VCO:TRACe:FREQuency?Read VCO Frequency. Returns the frequency in Hz at each tune voltage point as block data.None
CALCulate:VCO:TRACe:ISupply?Read VCO Supply Current. Returns the supply current in A at each tune voltage point as block data.None
CALCulate:VCO:TRACe:KPUSh?Read VCO Pushing. Returns the pushing in Hz/V at each tune voltage point as block data.None
CALCulate:VCO:TRACe:KVCO?Read VCO Kvco. Returns the tune sensitivity Kv in Hz/V at each tune voltage point as block data.None
CALCulate:VCO:TRACe:PNoise? <Offset>Read VCO Phase Noise. Returns the phase noise in dBc/Hz at each tune voltage point for offset 1 to 4 (SENSe:VCO:TEST:PNoise:OFFSet) as block data.Number: 1,2,3,4
CALCulate:VCO:TRACe:POWer?Read VCO Power. Returns the power in dBm at each tune voltage point as block data.None
CALCulate:VCO:TRACe:VOLTage?Read VCO Voltage. Returns the tune voltage values in V of each measurement point as block data.None
CALCulate:VCO:ITERation?Read VCO Iteration. Returns the iteration of the current VCO characterization (call CALCulate:VCO:WAIT first).None
CALCulate:VCO:WAIT ALLVCO Wait Complete. Blocks until the VCO characterization is finished.None
CALCulate:VCO:WAIT <Event>,<Timeout>VCO Wait Event. Blocks until the requested VCO iteration (NEXT / ALL / iteration number) is ready or the timeout in ms expires.Text: NEXT,ALL; Number

System (SYSTem) (17)

CommandWhat it doesArguments
SYSTem:ERRor:NEXT?Read Error. Returns and removes the next entry in the error queue (0 = No error).None
SYSTem:ERRor:ALL?Read All Errors. Returns all entries in the error queue and clears it (0 = measurement ok).None
SYSTem:RESTartRestart System. Restarts the instrument (same as a power cycle; terminates the connection).None
SYSTem:COMMunicate:GPIB:ADDRess <Address>Set GPIB Address. Sets the GPIB address (1 to 30).Number: 1,30
SYSTem:COMMunicate:GPIB:ADDRess?Read GPIB Address. Returns the GPIB address.None
SYSTem:COMMunicate:LAN:CONFig <Mode>Set LAN Config. Selects the IP configuration mode (DHCP / MANual / AUTO = DHCP with Auto-IP fallback).Text: DHCP,MANual,AUTO
SYSTem:COMMunicate:LAN:CONFig?Read LAN Config. Returns the IP configuration mode.None
SYSTem:COMMunicate:LAN:IP <IP>Set LAN IP. Sets the IP address (quoted string e.g. "192.168.1.100").Text
SYSTem:COMMunicate:LAN:IP?Read LAN IP. Returns the current IP address.None
SYSTem:COMMunicate:LAN:SUBNet <Mask>Set LAN Subnet. Sets the subnet mask (quoted string e.g. "255.255.255.0").Text
SYSTem:COMMunicate:LAN:SUBNet?Read LAN Subnet. Returns the current subnet mask.None
SYSTem:COMMunicate:LAN:GATEway <Gateway>Set LAN Gateway. Sets the default gateway (quoted string e.g. "192.168.1.1").Text
SYSTem:COMMunicate:LAN:GATEway?Read LAN Gateway. Returns the current default gateway.None
SYSTem:COMMunicate:LAN:RESTartRestart LAN. Restarts the network to apply LAN setting changes.None
SYSTem:COMMunicate:LAN:DEFaultsRestore LAN Defaults. Restores the factory default LAN settings (AUTO mode).None
SYSTem:COMMunicate:LAN:RTMO <Timeout>Set LAN Reconnect Timeout. Sets the LAN reconnect timeout in s (INFinite or 0 to 1e6).Text
SYSTem:COMMunicate:VXI:RTMO <Timeout>Set VXI Reconnect Timeout. Sets the VXI-11 reconnect timeout in s (INFinite or 0 to 1e6).Text

Source (SOURce) (7)

CommandWhat it doesArguments
SOUR:SUPP<Channel>:VOLT <Voltage>Set Supply Voltage. Sets the DUT DC supply voltage in V of supply channel 1 or 2 (0 to 15 V; manual VCO programming example).Number: 1,2; Number: 0,15
SOUR:SUPP<Channel>:STAT ONSupply On. Turns the DUT DC supply of the channel on (manual VCO programming example).Number: 1,2
SOUR:SUPP<Channel>:STAT OFFSupply Off. Turns the DUT DC supply of the channel off (manual VCO programming example).Number: 1,2
SOURce:TUNE:DUT:VOLT <Voltage>Set DUT Tune Voltage. Sets the voltage in V at the DUT TUNE port (*RST 0).Number
SOURce:TUNE:DUT:VOLT?Read DUT Tune Voltage. Returns the configured DUT TUNE port voltage in V.None
SOURce:TUNE:DUT:STAT ONDUT Tune On. Turns the DUT TUNE port output on.None
SOURce:TUNE:DUT:STAT OFFDUT Tune Off. Turns the DUT TUNE port output off.None

Initiate (INITiate) (1)

CommandWhat it doesArguments
INITiate:IMMediateStart Measurement. Arms the trigger and starts the measurement in the active mode.None

Abort (1)

CommandWhat it doesArguments
ABORtAbort Measurement. Aborts the measurement in progress.None

Other subsystem (1)

CommandWhat it doesArguments
<Output Variable>=<Equation>Math. Variable equals an equation like (${Var_name}= ${Var_name}/2)Number; Text

WAIT subsystem (1)

CommandWhat it doesArguments
wait(<ms>)Wait. Waits for number of millisecondsNumber

SAVE subsystem (1)

CommandWhat it doesArguments
save2var <Variable_name>Save2Variable. Saves last measurement to a variableText

IEEE 488.2 common commands (16)

CommandWhat it doesArguments
*OPT?Read Options. Returns a comma-separated list of the installed options.None
*OPCOperation Complete Bit. Sets bit 0 of the Standard Event Status Register when all pending operations have finished.None
*ESE <Value>Set Event Status Enable. Sets the Standard Event Status Enable register (0 to 255).Number: 0,255
*ESR?Read Event Status. Returns the Standard Event Status Register.None
*SRE <Value>Set Service Request Enable. Sets the Service Request Enable register (0 to 255).Number: 0,255
*SRE?Read Service Request Enable. Returns the Service Request Enable register.None
*STB?Read Status Byte. Returns the status byte including the master summary status bit.None
*SAV <Register>Save Setup. Saves the instrument settings to the given memory register.Number
*RCL <Register>Recall Setup. Recalls the instrument state from the given memory register.Number
*IDN?Identify. Returns the instrument identification string (manufacturer, model, serial, firmware).None
*RSTReset. Resets the instrument to its default state.None
*CLSClear Status. Clears all event registers and the error queue.None
*TST?Self Test. Runs the self-test and returns 0 for pass or 1 for failure.None
*OPC?Operation Complete. Returns 1 when all pending operations are complete.None
*WAIWait To Continue. Waits until all pending operations are complete before continuing.None
*TRGTrigger Bus. Triggers the device if LAN is the selected trigger source (otherwise ignored).None

Where these commands come from

This reference is generated from TestFlow's instrument library, which is drafted from AnaPico's programming documentation for the APPH20G, APPH40G, and APPH6040 and checked when the agent runs it. Ranges, timing, and option-dependent commands are defined by AnaPico's programming manual: check it before you rely on an edge case. Last updated September 26, 2026.

Frequently asked questions

Does the AnaPico APPH20G support SCPI remote control?

Yes. The AnaPico APPH20G accepts SCPI commands over its remote interfaces. TestFlow's instrument library holds 184 SCPI commands for it: 67 queries that read values or state, and 117 settings and actions.

How do I control the AnaPico APPH20G from Python?

Install PyVISA and a VISA backend, find the instrument's address with ResourceManager().list_resources(), open it, then send commands with write() and read values with query(). The example on this page sends *IDN?, SENSe:FREQuency:EXECute and SENSe:MODE?.

Which command reads a value from the AnaPico APPH20G?

SENSe:MODE? (read measurement mode). Returns the active measurement mode. The full list of queries is in the command reference on this page, grouped by subsystem.