In TestFlow's instrument library, the Keysight N6762A takes 135 SCPI commands, 36 of them queries, and the Keysight N6781A takes 155 SCPI commands, 36 of them queries. That is 20 more on the N6781A. Counting distinct command headers (the command path without its arguments), 111 are accepted by both, 3 exist only on the N6762A, and 18 only on the N6781A. 97% of the N6762A's command headers also exist on the N6781A.
Both libraries have commands under SOURce, OUTPut, SENSe, MEASure, TRIGger, FETCh, SYSTem, and INITiate, plus 4 more roots. Neither has a command root the other lacks: the differences are inside shared subsystems.
Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?.
Describe the test; TestFlow's agent uses these command sets to drive your Keysight N6762A or Keysight N6781A and writes the report from the measured results.
Counts come from TestFlow's instrument library, the command sets its AI agent uses to drive each instrument. A distinct command header is the command path without its arguments, so :OUTPut ON and :OUTPut OFF count once.
| Keysight N6762A | Keysight N6781A | |
|---|---|---|
| Commands in TestFlow's library | 135 | 155 |
| Queries (read a value or state) | 36 | 36 |
| Settings and actions | 99 | 119 |
| Subsystems | 16 | 16 |
| Distinct command headers | 114 | 129 |
| Headers the other lacks | 3 | 18 |
| Command language | SCPI | SCPI |
| Operation complete | *OPC? | *OPC? |
| Error queue | SYSTem:ERRor? | SYSTem:ERRor? |
| Models on this command set | N6762A | N6781A |
111 command headers are in both libraries. Here are 12, taken across subsystems.
| Command | What it does |
|---|---|
| SOURce:VOLTage <Volt>,(@<Channel>) | Set Voltage. Sets the output voltage in volts (programming range up to 51 V). |
| OUTPut ON,(@<Channel>) | Turn On. Enables the output of the N6762A module in the selected mainframe channel. |
| SENSe:FUNCtion:VOLTage ON,(@<Channel>) | Enable Voltage Measure Function. Enables the voltage measurement function for triggered data acquisitions. |
| MEASure:VOLTage:DC? (@<Channel>) | Measure Voltage. Takes a measurement and returns the average voltage in volts. |
| TRIGger:ACQuire:SOURce <Source>,(@<Channel>) | Set Acquire Trigger Source. Selects the measurement trigger source. |
| FETCh:VOLTage:DC? (@<Channel>) | Fetch Voltage. Returns the average voltage from the last acquisition without re-triggering. |
| SYSTem:CHANnel:MODel? (@<Channel>) | Read Channel Model. Returns the model number of the power module installed in the selected channel. |
| INITiate:ACQuire (@<Channel>) | Initiate Acquisition. Arms the measurement trigger system to receive triggers. |
| ABORt:ACQuire (@<Channel>) | Abort Acquisition. Resets the measurement trigger system to the idle state. |
| DISPlay:CHANnel <Channel> | Set Display Channel. Selects which channel is shown in the single-channel front-panel meter view. |
| FORMat:DATA ASCII | Set Data Format ASCII. Returns measurement array and data log values as comma separated ASCII text. |
| STATus:QUEStionable? (@<Channel>) | Read Questionable Status. Reads and clears the questionable event register that reports OV OC OT and inhibit conditions. |
3 command headers in the N6762A library have no match in the N6781A library. Below are 3 of them from the 3 largest subsystems; the full list is in the Keysight N6762A command reference.
| Command | What it does |
|---|---|
| OUTPut:PMODe <Mode>,(@<Channel>) | Set Turn On Mode. Selects whether the output prioritizes voltage or current during turn-on and turn-off transitions. |
| Command | What it does |
|---|---|
| SENSe:CURRent:CCOMpensate ON,(@<Channel>) | Enable Current Compensation. Corrects the current measurement for the current flowing into the output capacitor. |
| Command | What it does |
|---|---|
| SOURce:POWer:LIMit <Watt>,(@<Channel>) | Set Power Limit. Sets the output power limit in watts (100 W maximum on the N6762A). |
18 command headers in the N6781A library have no match in the N6762A library. Below are 9 of them from the 3 largest subsystems; the full list is in the Keysight N6781A command reference.
| Command | What it does |
|---|---|
| SOURce:FUNCtion <Mode>,(@<Channel>) | Set Priority Mode. Selects voltage priority or current priority mode for the source/measure unit. |
| SOURce:EMULation <Type>,(@<Channel>) | Set Emulation Mode. Selects the operating mode that the SMU emulates, such as a power supply, battery, load or meter. |
| SOURce:CURRent:LIMit:POSitive <Amp>,(@<Channel>) | Set Positive Current Limit. Sets the positive current limit in amps used in voltage priority mode. |
| SOURce:CURRent:LIMit:NEGative <Amp>,(@<Channel>) | Set Negative Current Limit. Sets the negative (sinking) current limit in amps used in voltage priority mode. |
| Command | What it does |
|---|---|
| SENSe:FUNCtion:VOLTage:INPut <Input>,(@<Channel>) | Set Voltage Measure Input. Selects the main output terminals or the auxiliary voltage input for voltage measurements. |
| SENSe:VOLTage:RANGe:AUTO ON,(@<Channel>) | Enable Voltage Measure Autorange. Enables seamless voltage measurement autoranging on the selected channel. |
| SENSe:CURRent:RANGe:AUTO ON,(@<Channel>) | Enable Current Measure Autorange. Enables seamless current measurement autoranging on the selected channel. |
| Command | What it does |
|---|---|
| OUTPut:TMODe <Mode>,(@<Channel>) | Set Turn Off Impedance. Specifies the high-impedance or low-impedance output state used during turn-on and turn-off. |
| OUTPut:PROTection:OSCillation ON,(@<Channel>) | Enable Oscillation Protection. Enables output oscillation protection which trips if the output oscillates. |
With PyVISA and any VISA backend, this opens both instruments, identifies them, sends one setting, and reads one value from each. For the setting, both libraries hold OUTPut:COUPle (enable output coupling), and the same line runs on each. For the reading, both libraries hold MEASure:VOLTage:DC? (measure voltage), and the same line runs on each. For the basics, see the PyVISA tutorial.
import pyvisa
rm = pyvisa.ResourceManager()
print(rm.list_resources()) # find both VISA addresses
a = rm.open_resource("PASTE_N6762A_ADDRESS") # Keysight N6762A
b = rm.open_resource("PASTE_N6781A_ADDRESS") # Keysight N6781A
for inst in (a, b):
inst.timeout = 5000 # ms
print(inst.query("*IDN?"))
# The same setting on both: Enable Output Coupling
a.write("OUTPut:COUPle ON")
b.write("OUTPut:COUPle ON")
# The same reading on both: Measure Voltage
print(a.query("MEASure:VOLTage:DC? (@1)"))
print(b.query("MEASure:VOLTage:DC? (@1)"))
a.close()
b.close()Describe the test; TestFlow's agent uses these command sets to drive your Keysight N6762A or Keysight N6781A and writes the report from the measured results.
In TestFlow's library the N6762A has 135 SCPI commands and the N6781A has 155 SCPI commands. 111 command headers are common to both, 3 are only on the N6762A (mostly OUTPut and SENSe), and 18 are only on the N6781A (mostly SOURce and SENSe).
Partly. 111 command headers are accepted by both, including SOURce:VOLTage, OUTPut, and SENSe:FUNCtion:VOLTage. 21 are not, for example OUTPut:PMODe on the N6762A and SOURce:FUNCtion on the N6781A, so a script that uses those needs a separate branch for each instrument.
The N6781A: 135 commands for the N6762A against 155 for the N6781A in TestFlow's library. Of those, 36 on the N6762A and 36 on the N6781A are queries that read a value or state, and the library splits them into 16 and 16 subsystems.
Both libraries synchronise with *OPC?. Both libraries read errors with SYSTem:ERRor?. Each command named here is listed in the tables on this page and on each instrument's command reference.
Describe the test. TestFlow builds the workflow, runs it on your instruments, and writes the report. See it on a bench like yours.